No comment |
>
Control System >
PLC >
AB PLC >
1756-OW16I Allen-Bradley PLC 16 Channel N.O Isolated Relay Output Module (36 Pin) New1756-OW16I Allen-Bradley PLC 16 Channel N.O Isolated Relay Output Module (36 Pin) NewIf you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.PLCAGE: 1756-OW16I Allen-Bradley PLC 16 Channel N.O Isolated Relay Output Module (36 Pin) New
Feature
The 1756 digital I/O modules support these features.
Variety of voltage interface capabilities
Isolated and nonisolated module types
Point-level output fault states
Direct-connect or rack-optimized communication
Field-side diagnostics on select modules
Specification
Outputs
16 N.O. individually isolated
Pilot duty
C300/R150
Operating voltage range
5-25V DC
10-40V AC
Output voltage range (load dependent)
2 A @ 5-0V DC
0.5 A @ 48V DC
0.25 A @ 125V DC
2 A @ 125/240V AC
Output delay time
Off to On
On to Off
10 ms max
10 ms max
Current draw @ 5.1V
150 mA
Current draw @ 24V
150 mA
Total backplane power
4.4 W
Power dissipation, max
4.5 W @ 60°C (140 ?)
Thermal dissipation
15.35 BTU/hr
Off-state leakage current per point, max
1.5 mA per point
Minimum load current
10 mA per point
Initial contact resistance, max
100 mOhm? @ 6V 1 A
Switching frequency, max
1 operation/3 s (0.3 Hz at rated load)
Bounce time, mean
1.2 ms
Expected contact life
300 K cycles resistive
100 K cycles inductive
Scheduled outputs
Synchronization within 16.7 s max, reference to the Coordinated System Time
States in Fault mode per point
Hold last state, On or Off (Off is default)
States in Program mode per point
Hold last state, On or Off (Off is default)
Isolation voltage
250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output
Routine tested @ 1350V AC for 2 s
Module keying
Electronic, software configurable
Fusing
Not protected. A fused IFM can be used to protect outputs. See publication 1492-TD008.
However, the ControlLogix system has been agency certified using only the ControlLogix
RTBs, that is, 1756-TBCH, 1756-TBNH, 1756-TBSH, and 1756-TBS6H. Any application that
requires agency certification of the ControlLogix system using other wiring termination
methods may require application-specific approval by the certifying agency.
Removable terminal block
1756-TBCH
1756-TBS6H
RTB keying
User-defined mechanical
Slot width
1
Wire category
1(1)
North American temperature code
T4A
Enclosure type
None (open-style)
No comment |