Your Position: Home > Control System > PLC > AB PLC > 1746-NT4 Allen-Bradley PLC 1746 RTD and Thermocouple Modules 4 Input 16 Bits New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

1746-NT4 Allen-Bradley PLC 1746 RTD and Thermocouple Modules 4 Input 16 Bits New

prevnext

1746-NT4 Allen-Bradley PLC 1746 RTD and Thermocouple Modules 4 Input 16 Bits New
  • Market price: $ 3016.2
  • Shop price: $ 914.0
  • Goods click count: 209
  • Total:
  • Quantity:
Add to cart collect
  

Description

1746-NT4 Allen-Bradley PLC 1746 RTD and Thermocouple Modules 4 Input 16 Bits New

If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.

PLCAGE: 1746-NT4 Allen-Bradley PLC 1746 RTD and Thermocouple Modules 4 Input 16 Bits New

Features

The thermocouple/mV module receives and stores digitally converted thermocouple and/or millivolt (mV) analog data into its image table for retrieval by all fixed and modular SLC 500 processors. The module supports connections from any combination of up to four thermocouple or mV analog sensors.

Specification

Specification

Value

Backplane Current

Consumption

60 mA at 5V dc

40 mA at 24V dc

Backplane Power

Consumption

0.8W maximum?(0.3W @ 5V dc, 0.5W @ 24V dc)

Number of Channel

4 (backplane isolated)

I/O Chassis Location

Any I/O module slot except slot 0

?/p>

A/D Conversion Method

Sigma-Delta Modulation

Input Filtering

Low pass digital filter with programmable notch (filter)

frequencies

?/p>

Normal Mode Rejection

(between [+] input and [-]

Input)

Greater than 100 dB at 50 Hz (10 Hz, 50 Hz filter frequencies)

Greater than 100 dB at 60 Hz (10 Hz, 60 Hz filter frequencies)

?/p>

Common Mode Rejection

(between inputs and chassis

Ground)

Greater than 150 dB at 50 Hz (10 Hz, 50 Hz filter frequencies)

Greater than 150 dB at 60 Hz (10 Hz, 60 Hz filter frequencies)

?/p>

Input Filter Cut-Off

Frequencies

2.62 Hz at 10 Hz filter frequency

13.1 Hz at 50 Hz filter frequency

15.72 Hz at 60 Hz filter frequency

65.5 Hz at 250 Hz filter frequency

?/p>

Calibration

Module autocalibrates at power-up and whenever a channel

is enabled.

?/p>

Isolation

500V dc continuous between inputs and chassis ground, and

between inputs and backplane

Maximum

Channel-to-Channel

Common-Mode Separation

Series B or later:?2V maximum between any two channels

Series A:?0V separation

?/strong>

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: