Features
The RTD module supplies a small current to each RTD connected to the module inputs (up to 8 input channels). The module provides on-board scaling and converts RTD input to temperature (°C °F or reports resistance input in ohms.)
Specification
1746-NR4
1746-NR8
Backplane Current Consumption
50 mA at 5V dc
50 mA at 24V dc
100 mA at 5V dc
55 mA at 24V dc
Backplane Power Consumption
1.5W maximum
(0.3 W at 5V dc, 1.2 W at 24V dc)
1.82W maximum
(0.5W at 5V dc, 1.32W at 24V dc)
External Power Supply Requirements
None
Number of Channels
4 (backplane isolated)
8 (backplane isolated)
I/O Chassis Location
Any I/O module slot except slot 0
A/D Conversion Method
Sigma-Delta Modulation
Input Filtering
Low pass digital filter with programmable notch (filter) frequencies
Common Mode Rejection (between
inputs and chassis ground)
> 150 dB at 50 Hz (10 Hz and 50 Hz filter
frequencies)
> 150 dB at 60 Hz (10 Hz and 60 Hz filter
frequencies)
> 120 dB at 50 Hz (28 Hz and 50 Hz filter
frequencies)
> 120 dB at 60 Hz (28 Hz and 60 Hz filter
frequencies)
Normal Mode Rejection (between [+]
input and [-] input)
Greater than 100 dB at 50 Hz (10 Hz, 50 Hz filter
frequencies)
Greater than 100 dB at 60 Hz (10 Hz, 60 Hz filter
Frequencies)
65 dB at 50/60 Hz (with 50/60 Hz filter)
110 dB at 50 Hz (with 28 Hz filter)
95 dB at 60 Hz (with 28 Hz filter)
Maximum common mode voltage
± 1 volt
Maximum allowed permanent
overload
Volts: ± 5V dc
Current: ± 5mA
Input Filter Cut-Off Frequencies
2.62 Hz at 10 Hz filter frequency
13.1 Hz at 50 Hz filter frequency
15.72 Hz at 60 Hz filter frequency
65.5 Hz at 250 Hz filter frequency
7.80 Hz at 28 Hz filter frequency
13.65 Hz at 50/60 Hz filter frequency
209.6 Hz at 800 Hz filter frequency
1676 Hz at 6400 Hz filter frequency
Calibration
Module autocalibrates when power is applied, a
channel is enabled or when a change is made to
its input type, filter frequency, or excitation
current.
Set module calibration disable to zero to enable
module to autocalibrate when power is applied,
a channel is enabled, or when a change is made
to the input type, filter frequency, or excitation
current.
Isolation (optical)
500V dc continuous between inputs and chassis
ground, and between inputs and backplane
707V dc for 1 minute
Isolation Between Inputs
None
±5V dc