No comment |
>
Control System >
PLC >
Delta PLC >
DVP04AD-H2 Delta PLC 4 point 14-bit resolution Analog Module Original brand newDVP04AD-H2 Delta PLC 4 point 14-bit resolution Analog Module Original brand new
Introduction
1. Thank you for choosing Delta DVP series PLC. DVP04AD-H2 is able to receive 4 points of analog input signals (voltage or current) and convert them into 14-bit digital signals. Besides, through FROM/TO instructions in DVP-EH2 MPU program, the data in DVP04AD-H2 can be read or written. There are 49 16-bit control registers (CR) in DVP04AD-H2.
2. You can select voltage or current output by wiring. Range of voltage output: ±10V DC (resolution: 1.25mV). Range of current output: +-20mA (resolution: 5μA).
Specification
Analog/Digital (4A/D) module
Voltage input
Current input
Power supply voltage
24V DC (20.4V DC ~ 28.8V DC) (-15% ~ +20%)
Analog input channel
4 channels/module
Range of analog input
+-10V
+-20mA
Range of digital conversion
+-8,000
+-4,000
Resolution
14 bits (1LSB = 2.5mV)
13 bits (1LSB = 5uA)
Input impedance
0.5? or lower
Overall accuracy
+-0.5% when in full scale (25°C, 77°F)
+-1% when in full scale within the range of 0 ~ 55°C, 32 ~ 131°F
Responding time
3ms × the number of channels
Isolation
Internal circuit and analog output terminals are isolated by optical coupler.
No isolation among analog channels.
Range of absolute input
+-15V
+-32mA
Digital data format
13 significant bits out of 16 bits are available; in 2’s complement
Average function
Yes. Available for setting up in CR#2 ~ CR#5; range: K1 ~ K20.
Self-diagnosis
Upper and lower bound detection/channel
Communication mode
(RS-485)
ASCII/RTU mode. Communication speed: 4,800/9,600/19,200/38,400/57,600/115,200 bps. ASCII data format: 7-bit, even bit, 1 stop bit (7, E, 1). RTU data format: 8-bit, even bit, 1 stop bit (8, E, 1). RS-485 cannot be used when connected to PLC MPU.
When connected to DVP-PLC
MPU in series
The modules are numbered from 0 to 7 automatically by their distance from MPU. No.0 is the closest to MPU and No.7 is the furthest. Maximum 8 modules are allowed to connect to MPU and will not occupy any digital I/O points.
Max. rated power consumption
24V DC (20.4V DC ~ 28.8V DC) (-15% ~ +20%), 2.5W, supplied by external power
Operation/storage
Operation: 0°C ~ 55°C (temperature); 5 ~ 95% (humidity); pollution degree 2
Storage: -25°C ~ 70°C (temperature); 5 ~ 95% (humidity)
Vibration/shock immunity
International standards: IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27
(TEST Ea)
Product Profile
No comment |