Your Position: Home > Control System > PLC > Schneider PLC > TSXCTY2A Schneider PLC NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: service@plcage.com
Tel: 0086-574-88333153
   

TSXCTY2A Schneider PLC NEW

prevnext

TSXCTY2A Schneider PLC NEW
  • Market price: $ 1656.6
  • Shop price: $ 502.0
  • Goods click count: 328
  • Total:
  • Quantity:
Add to cart collect
  

Description

TSXCTY2A Schneider PLC NEW

If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:service@plcage.com
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.

Schneider PLC TSXCTY2A

Product description:

Main:

Range of product Modicon Premium Automation platform

Product or component

type

Counter modules

I/O modularity 2 channels

Electrical circuit type Auxiliary output conforming to EN/IEC 61131

Complementary:

Counting frequency 40 kHz

Power dissipation in W 4.5...6 W

Module cycle time 5

Discrete input logic Current sink auxiliary input (preset, enable and read) conforming to IEC 1131

Type 2

Resistive 2/3-wire proximity sensors PNP/NPN input conforming to IEC 1131

Type 2

Resistive encoder input

Input logic Positive

Input compatibility 2/3-wire proximity sensors PNP/NPN

Incremental encoder 10...30 V totem pole

Incremental encoder 5 V DC RS422

Input voltage 24 V 18 mA 2/3-wire proximity sensors PNP/NPN

24 V 7 mA auxiliary input (preset, enable and read)

5 V 18 mA encoder input

Input voltage limits <= 5.5 V encoder input

19...30 V 2/3-wire proximity sensors PNP/NPN

19...30 V auxiliary input (preset, enable and read)

Voltage state1 guaranteed >= 11 V 2/3-wire proximity sensors PNP/NPN

>= 11 V auxiliary input (preset, enable and read)

>= 2.4 V encoder input

Current state 1 guaranteed > 3.7 mA encoder input

> 6 mA 2/3-wire proximity sensors PNP/NPN

> 6 mA auxiliary input (preset, enable and read)

Voltage state 0 guaranteed <= 1.2 V encoder input

<= 5 V 2/3-wire proximity sensors PNP/NPN

<= 5 V auxiliary input (preset, enable and read)

Current state 0 guaranteed < 1 mA encoder input

< 2 mA 2/3-wire proximity sensors PNP/NPN

< 2 mA auxiliary input (preset, enable and read)

Response time < 2.5 ms sensor voltage at loss of 24 V auxiliary input (preset, enable and read)

Input impedance > 270 Ohm at U = 2.4 V encoder input

1400 Ohm at Un 2/3-wire proximity sensors PNP/NPN

3400 Ohm at Un auxiliary input (preset, enable and read)

400 Ohm at Un encoder input

Output voltage 24 V DC

Nominal output current 0.5 A

Output voltage limits 19...30 V

Voltage drop < 0.5 V at state 1

Output compatibility Positive logic DC inputs (resistance <= 15 kOhm) auxiliary output

Leakage current < 0.1 mA

Switching time < 250 μs

Switching frequency < 0.6/LI² Hz on inductive load

Output overload protection Current limiter

Thermal tripping via program or automatically

Output short-circuit protection Current limiter

Thermal tripping via program or automatically

Output overvoltage protection Zener diode

Reverse polarity protection Reverse diode on supply

Checks Sensor power supply

Current consumption 280 mA 5 V DC

30 mA 24 V DC

Module format Standard

Local signalling 1 LED green module operating (RUN)

1 LED red external fault (I/O)

1 LED red internal fault, module failure (ERR)

2 LED green axis diagnostics available (CH.)

 

TSXCTY2A Schneider PLC NEW

If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:service@plcage.com
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.

Schneider PLC TSXCTY2A

Product description:

Main:

Range of product Modicon Premium Automation platform

Product or component

type

Counter modules

I/O modularity 2 channels

Electrical circuit type Auxiliary output conforming to EN/IEC 61131

Complementary:

Counting frequency 40 kHz

Power dissipation in W 4.5...6 W

Module cycle time 5

Discrete input logic Current sink auxiliary input (preset, enable and read) conforming to IEC 1131

Type 2

Resistive 2/3-wire proximity sensors PNP/NPN input conforming to IEC 1131

Type 2

Resistive encoder input

Input logic Positive

Input compatibility 2/3-wire proximity sensors PNP/NPN

Incremental encoder 10...30 V totem pole

Incremental encoder 5 V DC RS422

Input voltage 24 V 18 mA 2/3-wire proximity sensors PNP/NPN

24 V 7 mA auxiliary input (preset, enable and read)

5 V 18 mA encoder input

Input voltage limits <= 5.5 V encoder input

19...30 V 2/3-wire proximity sensors PNP/NPN

19...30 V auxiliary input (preset, enable and read)

Voltage state1 guaranteed >= 11 V 2/3-wire proximity sensors PNP/NPN

>= 11 V auxiliary input (preset, enable and read)

>= 2.4 V encoder input

Current state 1 guaranteed > 3.7 mA encoder input

> 6 mA 2/3-wire proximity sensors PNP/NPN

> 6 mA auxiliary input (preset, enable and read)

Voltage state 0 guaranteed <= 1.2 V encoder input

<= 5 V 2/3-wire proximity sensors PNP/NPN

<= 5 V auxiliary input (preset, enable and read)

Current state 0 guaranteed < 1 mA encoder input

< 2 mA 2/3-wire proximity sensors PNP/NPN

< 2 mA auxiliary input (preset, enable and read)

Response time < 2.5 ms sensor voltage at loss of 24 V auxiliary input (preset, enable and read)

Input impedance > 270 Ohm at U = 2.4 V encoder input

1400 Ohm at Un 2/3-wire proximity sensors PNP/NPN

3400 Ohm at Un auxiliary input (preset, enable and read)

400 Ohm at Un encoder input

Output voltage 24 V DC

Nominal output current 0.5 A

Output voltage limits 19...30 V

Voltage drop < 0.5 V at state 1

Output compatibility Positive logic DC inputs (resistance <= 15 kOhm) auxiliary output

Leakage current < 0.1 mA

Switching time < 250 μs

Switching frequency < 0.6/LI² Hz on inductive load

Output overload protection Current limiter

Thermal tripping via program or automatically

Output short-circuit protection Current limiter

Thermal tripping via program or automatically

Output overvoltage protection Zener diode

Reverse polarity protection Reverse diode on supply

Checks Sensor power supply

Current consumption 280 mA 5 V DC

30 mA 24 V DC

Module format Standard

Local signalling 1 LED green module operating (RUN)

1 LED red external fault (I/O)

1 LED red internal fault, module failure (ERR)

2 LED green axis diagnostics available (CH.)

 

  