No comment |
>
Motion Control System >
Servo system >
ASD-A2-3023-M Delta AC Servo Drive 3ph 220V 3KW 19.4A CANopen E-CAM with Full-Closed Control NewAC Servo Drive ASD-A2-3023-M available, if need other choices, contact us directly,we can also supply ASD-A2-3023-L, ASD-A2-3023-U.
Drive Specifications
Model
ASD-A2-3023-M
Product Name
AC SERVO Drive
Corresponding Servo Motor
ECMA-C?1330()4 (4=24mm)
ECMA-E?1830()S (S=35mm)
ECMA-E?1835()S (S=35mm)
ECMA-F?1830()S (S=35mm)
Series
A2
Model Type
Full-Closed CANopen E-CAM
Rated Power
3KW
Power
Phase / Voltage
Three-phase 220 VAC
Permissible Voltage
Three-phase 200 ~ 230 VAC, -15% ~ 10%
Continuous Output Current
19.4 Arms
Cooling method
Fan Cooling
Encoder Resolution (Servo Drive Resolution)
Incremental type: 20-bit (1280000 p/rev) ; Absolute type: 17-bit (1280000 p/rev)
Main Circuit Control
SVPWM (Space Vector Pulse Width Modulation) Control
Control Mode
Auto / Manual
Dynamic Brake
Built-in
Position
Control
Mode
Max. Input Pulse
Frequency
Max. 500Kpps / 4Mpps (Line driver), Max. 200Kpps (Open collector)
Pulse Type
Pulse + Direction, A phase + B phase, CCW pulse + CW pulse
Command Source
External pulse / Register
Smoothing Strategy
Low-pass and P-curve filter
E-gear ratio
E-gear ratio N/M multiple N: 1~32767, M: 1:32767 (1/50 < N/M < 25600)
Torque Limit
Parameter settings
Feed Forward Compensation
Parameters settings
Speed
Control
Mode
Analog
Command
Input
Voltage
Range
0 ~ ±10 VDC
Input
Resistance
10 KΩ
Time
Constant
2.2 us
Speed Control Range*1
1 : 5000
Command Source
External analog command / Register
Smoothing Strategy
Low-pass and S-curve filter
Torque Limit
Via parameter setting or analog input
Bandwidth
Maximum 1 kHz
Speed Accuracy*2
0.01% or less at 0 to 100% load fluctuation
0.01% or less at ±10% power fluctuation
0.01% or less at 0 to 50 degree centigrade ambient temperature fluctuation
Torque
Control
Mode
Analog
Command
Input
Voltage
Range
0 ~ ±10 VDC
Input
Resistance
10 KΩ
Time
Constant
2.2 us
Command Source
External analog command / Register
Smoothing Strategy
Low-pass filter
Speed Limit
Via parameter setting or analog input
Analog Monitor Output
Monitor signal can set byparameters (Output voltage range: ±8 V)
Communication Interface
RS-232 / RS-485 / USB
external dimension (mm)
No comment |