No comment |
>
Motion Control System >
Servo system >
Kinco Servo Driver ED Series ED630-0250-AA-G-000 1.2-4.0KW 3 Phase AC380V+/-15% NewKinco Servo Driver ED Series ED630-0250-AA-G-000 1.2-4.0KW 3 Phase AC380V+/-15% New Free shippingIf you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574- 88333153
We will quote you our best price to you in 24hours.Specifications:
ED620/ED630
Main Supply Voltag: 3-Phase AC380V+/-15%
Rated Output Power(KW): 1.2-4.0
Dimensions mm: 300X166X115.5 300X166X125.5
Mode
ED620/ED630
ED620-0120-
XA-G-000
ED620-0150-
XA-G-000
ED620-0180-
XA-G-000
ED630-0250-
XA-G-000
ED630-0300-
XA-G-000
ED630-0400-
XA-G-000
Main Supply Voltage
3-Phase AC380V±15%
Rated Power Frequency
50Hz-60Hz
Control Power Supply
DC24±10%, 2A
Digital Signal Input
DC24±10%, 10mA
Digital Signal Output
DC24±10%, 0.5A
Analog Signal Snput
-10V~ +10V
Rated Output Power(KW)
1.2
1.5
1.8
2.5
3
4
Energy-Consumed Braking
If the system generates an Over-Voltage alarm when it starts or stops sharply, add an external braking resistor to absorb the feedback energy of the motorW
Energy-Consumed Braking Voltage
DC670±5V
Over-Voltage Alarm Voltage
DC710±5V
Under-Voltage Alarm Voltage
DC410±5V
Dimensions mm (H×W×D)
300X166X115.5
300X166X125.5
Weight
4.6
4.5
Operating Temperature
0~40 °C
Storage Temperature
-10 °C ~70 °C
Humidity
5~ 85%
Contamination Level
2
Protection Level
IP20
Installation Environment
Installed in a Dust-Free, Dry, and Lockable Environment (in a Electrical Cabinet, for Example)
Installation Mode
Vertical Installation
Installation Altitude
No Power Limit Under 1000m
Pressure
86~ 106kpa
Internal Programmable
An Internal Space of 16.5 KB is Provided for 256 Sequences, Which can Save a Controller on some Occasions
External I/O
3 External Digital Outputs (24V,0.5A),the Target Position to Output or Alarm Output Function can be Implemented by Internal Programming;
8 External Digital Inputs, Supporting Internal Sequence Calling Via the Input Interface and Positioning Function
(input delay: about 1 ms; input current: about 4 mA)
Analog Input
ne Differential Analog Input, Implementing Control over Motor Speed and Position by Analog Input; Input Voltage Range ± 10V, Input Delay: About 0.1 ms
Analog Output
Two Independent Analog Outputs, Capable of Monitoring the Change of Internal Objects
Comparator
Four Internal Comparators, with the Comparison Results to be Used to Trigger Program Sequences
Timer
Supporting the Function of Triggering Sequences by Timer or Events
Counter
Four Groups of Internal Counters, Which can be Set to Trigger Sequences
Calculator
An Internal Calculator can be Used for Data Duplication, Addition, Subtraction, Multiplication, and Division, and Logic Operation
Internal Oscilloscope
The ECO2WIN Software Enables a User to Monitor Operation Parameters Such as Speed, Position and Current on a PC
Encoder Signal Output Function
In a Master/Slave Control Mode, the Motor Encoder Signal or Master Encoder Signal can be the Input for the Slave Signal Encoder, with a Maximum Output Frequency of 2 MHz
Master Encoder Signal Input Function
Programmable to be Pulse/Direction Signal Control, CW/CCWW Control, Electronic gear or Electronic Cam Control (5V Signal), with a Maximum Output Frequency of 2 MHz
Feedback Signal
Incremental A, B, Z , /A, /B, /Z signal
RS232
9.6K Baud Rate, Supporting a Maximum of 15 Sites, and Supporting Direct Communication with a PC with the ECO2WIN Software, or Direct Communication with an eView Touch Screen or Text
RS485
38.4K Baud Rate, Supporting a Maximum of 15 Sites, and Communication Cables with a Length up to 400M
CAN BUS
Maximum Baud Rate of 1M, and Supporting a Maximum of 127 Sites
PROFIBUS DP
Maximum Baud Rate of 12M, and Supporting a Maximum of 127 Sites
No comment |