No comment |
>
Control System >
Inverter >
3-Phase 400V 8.8A 3.7KW 5HP TECO Inverter N310-4005-S3X NEW
Product Specifications
Single / Three phase, 200-240V model
N310-xxxx-XXX
20P5
2001
2002
2003
Horsepower(HP)
0.5
1
2
3
Max Applicable Motor Output (KW)
0.4
0.75
1.5
2.2
Rated Output Current(A)
3.1
4.5
7.5
10.5
Rated Capacity(KVA)
1.2
1.7
2.9
4.0
Max. Input Voltage
Single/Three Phase: 200~240V +10% -15%, 50/60HZ,+- 5%
Max. Output Voltage
Three Phase: 200~240V
Input Current(A)
8.5/4.5
12/6.5
16/11
23.9/12.5
Net Weight (KG)
1.4
1.4
2.5
4.0
Allowable momentary power loss
time (second)
1.0
1.0
2.0
2.0
Three phase, 380 – 480V model
N310-xxxx-XXX
4001
4002
4003
4005
4008
4010
4015
Horsepower(HP)
1
2
3
5
7.5
10
15
Max Applicable Motor Output (KW)
0.75
1.5
2.2
3.7
5.5
7.5
11
Rated Output Current(A)
2.3
3.8
5.2
8.8
13.0
17.5
25
Rated Capacity(KVA)
1.7
2.9
4.0
6.7
9.9
13.3
19.1
Max. Input Voltage
Three phase 380~480V +10%-15% 50/60HZ+-5%
Max. Output Voltage
Three Phase 380V~480V
Input Current(A)
4.2
5.6
7.3
11.6
17
23
31
Net Weight (KG)
2.4
2.5
3.8
4.0
4.0
7.0
7.0
Allowable momentary power loss
time (second)
1.0
1.0
2.0
2.0
2.0
2.0
2.0
General Specifications
Item
N310 TYPE
Control Mode
V/F or Current Vector Control
Frequency Control
Range
0.01~400.00 Hz
Start control torque
150%/1Hz ( Vector)
Speed control range
1:100 ( Vector)
Speed Control Precision
+-0.5% (Vector)
Setting resolution
Digital: 0.01Hz, Analog: 0.06Hz/ 60Hz(10bits)
Keypad setting
Set directly with”up””down” keys or the VR on the keypad
Display Function
Five digital LED and status indicator; display frequency/ line speed/ DC voltage/ Output voltage/ Current/ Rotation direction/ Inverter parameter/ Fault Log/ Program Version / Heat sink temperature/PID feed back
External signal setting
1. External potentiometer0-10V/ 0-20mA
2. Provides up/down controls, speed control or automatic procedure control with multifunctional contacts on the terminal block (TM2)
Frequency Limit
Function
Upper/lower frequency limits and three programmable skip
frequencies
Carrier frequency
1~ 15 kHz
V/F pattern
18 fixed patterns, 1programable curve
Acc/Dec control
Two-stage Acc/Dec time (0.1 – 3,600 seconds) and four-stage S curves (refer to descriptions on 10-07..)
Multifunction analog
output
5 functions (refer to description on 2-12)
Multifunction input
23 functions (refer to description on 01-00~01-05)
Multifunction output
14functions (refer to description on 01-09~01-10)
Other Functions
Momentary Power Loss Restart, Speed Search, Overload Detection, 16 preset speeds. Acc/Dec Switch (2 Stages), S Curves, 3-wire Control, PID control, torque boost, Slip Compensation, Frequency Upper/ Lower Limit, Auto energy saving, Modbus slave and PC/PDA Link, Auto Restart,
Encoder input.
Communication Control
1. Control by RS232 or RS485
2. One to one or one to many (RS485 ONLY) control.
3. BAUD RATE/STOP BIT/PARITY/bit can be set
Braking Torque
About 20%, the model below 20HP with built-in braking transistor and the specified external braking resistors can provide 100%
Operation temperature
14-1200F(-10 ~ 500C)
Storage temperature
4-1400F(-20 ~ 600C)
Humidity
0 -95% Relative Humidity(Non-condense)
Vibration
1G (9.8m/ S2 )
Enclosure
IP20
Protective Functions
Overload protection
The relays to protect the motor (the curve can be set) and the inverter (150 % / 1min)
Over Voltage
200V class: DC Voltage>410V 400Vclass: DC Voltage>820V
Under Voltage
200V class: DC Voltage<190V 400Vclass: DC Voltage<380V
Momentary Power
Loss Restart
Restart can be initiated with spin start after momentary power loss in Max 2 sec
Stall Prevention
Stall prevention for Acceleration/ Deceleration/ Operation.
Short-circuit output
terminal
Electronic Circuit Protection
Grounding Fault
Electronic Circuit Protection
Other Function
Protection for overheating of heat sink, over torque detection, error contact control, reverse prohibit, prohibit for direct start after power up and error recovery, parameter lock up.
Wiring
No comment |