No comment |
>
Control System >
Inverter >
SJ200-007HFE Frequency converter SJ200 series 3-phase 380 ~ 420V AC NEWSJ200-007HFE HITACHI Frequency converter SJ200 series 3-phase 380 ~ 420V AC NEWIf you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.Features:
Capacity Range: 0.2 – 7.5 kW
Global Standards to CE, UL, c-UL, cTick and CSA
Integrated RS485 Interface
Internal Brake Chopper
Sensorless Vector Control (SLV)
Integrated EMC-Filter
200% Starting Torque
Built-in Potentiometer
PID Control
Automatic Voltage Regulation
Motor Thermistor Input
Specifications:
Inverter SJ200
200V-Series
400V-Series
002
004
005
007
011
015
022
004
007
015
022
030
040
055
075
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
NFEF2
Applicable motor (kW)
0.2
0.4
0.55
0.75
1.1
1.5
2.2
0.4
0.75
1.5
2.2
3.0
4.0
5.5
7.5
Rated output current (A)
1.6
2.6
3.0
4.0
5.0
8.0
11.0
1.5
2.5
3.8
5.5
7.8
8.6
13.0
16.0
Input supply phase
Single phase / three phase
Three phase
Rated input voltage
200 VAC –10 % ~ 240 VAC +10 % 50/60 Hz ±5 %
380 VAC -10 % ~ 460 VAC +10 % 50/60 Hz ±5 %
Rated output voltage
Three phase 200 ~ 240VAC (corresponds to input voltage)
Three phase 380 ~ 460 VAC (corresponds to input voltage)
Output frequency range
0.5 ~ 400 Hz
Frequency accuracy
Digital command: ±0.01 % of maximum frequency
(at 25 °C ±10 °C)
(Analogue command: ±0.1 % of maximum frequency)
Frequency setting resolution Digital setting
Digital setting: 0.1 Hz Analogue setting: maximum frequency / 1000
Voltage/frequency characteristic
Intelligent sensorless vector control, constant or reduced torque
Overload capacity (current)
150 % for 60 seconds (once every 10 minutes)
Acceleration/deceleration time
0.01 ~ 3000 s in selectable linear and non-linear mode (second acceleration/deceleration usable)
Starting torque (using SLV)
200 % or more
180 % or more
Braking torque
Dynamic braking,
approx. 100 %
approx. 100 %
approx. 20 %
approx. 100 %
approx.70 %
approx.20 %
feedback to capacitor (50 Hz)
approx. 100 %
approx. 100 %
approx. 150 %
approx. 100 %
approx. 100 % approx
DC injection braking
Variable operating frequency, time and braking force can be set
Inputs
Frequency setting
Digital operator
Settings using keys or potentiometer
External signals
0-10 VDC (input impedance 10k ohm) 4-20 mA (input impedance 250 ohm) potentiometer 1k-2k ohm, 2 W
Forward / reverse run
Digital operator
Via keys RUN (for start) and STOP/RESET (for stop) (default setting: forward run)
External signals
Forward run/stop, Reverse run/stop
Intelligent input terminals
FW: Forward run start/stop RV: Reverse run start/stop CF1–CF4: Multistage speed JG: Jogging command AT: Analogue current input selection
programmable as, i.e.
2CH: 2nd accel./decel. time FRS: Free run stop EXT: External trip USP: USP function RS: Reset SFT: Software lock PTC: Thermal protection
DB: Ext. DB input SET: 2nd setting active UP: Acceleration (remote) DWN: Decelerate (remote)
Outputs
Intelligent output terminals
FA1/FA2: Frequency arrival signal RUN: Motor running signal OL: Overload signal OD: Deviation signal at PID control AL: Alarm signal
programmable as, i.e.
Frequency and current monitoring
0-10 VDC, 8 bit
PID loop operation
Air velocity, temperatur etc.
Other functions
Autotuning, automatic voltage regulation, analog input calculate function, automatic carrier frequency reduction, frequency jump,
output frequency display, trip history monitoring, carrier frequency setting, PID control, automatic torque boost, USP function,
2nd setting function, ON/OFF control of cooling fanStandards
CE, UL, cUL, c-Tick
Thermal motor protection
Thermistor input PTC (intelligent input 5)
Protection functions
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault at starting , overload, CT error, BRD error
Environmental
conditionsAmbient temperature
-10 ~ 50 °C; > 40 °C current
Storage temperature and humidity
?-25 ~ 60 °C
20 ~ 90 % RH (no dew condensation)
Options
Remote operator, copy unit, cable for digital operator, reactor for improving power factor, noise filter, ProDrive software
Protection class
IP20
Overall weight (approx.) in kg
0.7
0.8
1.8
1.8
2.8
1.3
1.7
2.8
3.8
5.7
No comment |