SV008iG5-4 LS Electrogenesis converter iG5 series NEW

If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.

Features:

Selectable V/f, sensorless vector control

Motor parameter Auto-tuning

Powerful torque at overall speed range

0.1 ~ 400Hz frequency output

-15% ~ +10% input voltage margin

Fault history: Last 5 faults

0~10Vdc / -10 ~ +10Vdc analog input

IP20 enclosure, UL Type 1 (Option)

Selectable manual/automatic torque boost

Selectable PNP/NPN input signal

2nd motor control and parameter setting

Built-in Dynamic braking transistor as standard

Enhanced process PID control

Built-in RS485 (LS Bus / Modbus RTU) communication

Cooling fan On/Off control & Easy change

Remote control using external keypad * RJ45 cable(Optional)

Upgraded functions:

Sleep & Wake-up (Energy savings)

KEB(Kinetic Energy Buffering) protection

Low leakage PWM algorism

Monitoring & commissioning PC based software tool (Drive View)

Specifications:

1 Phase 200V

SV***iG5A-1***

004

008

015

Max.
capacity 1)

(HP)

0.5

1.9

2

(kW)

0.4

0.75

1.5

Output
rating

Capacity (kVA) 2)

0.95

1.9

3.0

FLA (A) 3)

2.5

5

8

Max frequency

400 [Hz] 4)

Max voltage

3 phase 200~230V 5)

Input
rating

Rated voltage

1 phase 200~230 VAC (+10%, -15%)

Rated frequency

50~60 [Hz] (±5%)

Cooling method

Forced air cooling

Weight (kg)

0.76

1.12

1.84

Indicate the maximum applicable motor capacity when using 4 pole LS standard motor.

Rated capacity is based on 220V for 200V series and 440V for 400V series.

Refer to 15-3 of user’s manual when carrier frequency setting (39) is above 3kHz.

Max. frequency setting range is extended to 300Hz when H40 (Control mode select) is set to 3 (Sensorless vector control).

Max. output voltage cannot be higher than the input voltage. It can be programmable below input voltage.

Control

Control method

V/F, Sensorless vector control

Frequency setting resolution

Digital command: 0.01Hz
Analog command: 0.06Hz (Max. freq.: 60Hz)

Frequency accuracy

Digital command: 0.01% of Max. output frequency
Analog command: 0.1% of Max. output frequency

V/F pattern

Linear, Squared, User V/F

Overload capacity

150% per 1 min.

Torque boost

Manual/Auto torque boost

Dynamic
braking

Max. braking
torque

20% 1)

Max. Duty

150% when using optional DB resistor 2)

Operation

Operation mode

Keypad/ Terminal/ Communication option/ Remote keypad selectable

Frequency setting resolution

Analog: 0~10V, -10~10V, 0~20mA
Digital: Keypad

Operation features

PID, Up-down, 3-wire

Input

Multi-function
terminal
P1-P8

NPN/PNP selectable

FWD/REV RUN, Emergency stop, Fault reset, Jog operation, Multi-step Frequency-High, Mid, Low,
Multi-step Accel/Decel-High, Mid, Low, DC braking at stop, 2nd motor select, Frequency UP/Down,
3-wire operation, External trip A, B, PID-Inverter (V/F) operation bypass,
Option-inverter (V/F) operation bypass, Analog Hold, Accel/Decel stop

Output

Open collector
terminal

Fault output and
inverter status output

Less than DC 24V, 50mA

Multi-function relay

(N.O., N.C.) Less than AC 250V, 1A; Less than DC 30V, 1A

Analog output (AM)

0~10Vdc (less than 10mA): Output freq, Output current, Output voltage, DC link selectable

Protective
function

Trip

Over voltage, Under voltage, Over current, Ground fault current detection, Inverter overheat,
Motor overheat, Output phase open, Overload protection, Communication error,
Loss of speed command, Hardware fault, Fan trip

Alarm

Stall prevention, Overload

Momentary power loss

Below 15 msec.: Continuous operation (Should be within rated input voltage, rated output power.)
Above 15 msec.: Auto restart enable

Environ
ment

Protection degree

IP 20, NEMA1 (Optional)

Ambient temp

-10?~50?

Storage temp

-20?~65?

Humidity

Below 90% RH (No condensation)

Altitude/Vibration

Below 1,000m, 5.9m/sec2 (0.6G)

Atmospheric pressure

70~106 kPa

Location

Protected from corrosive gas, Combustible gas, Oil mist or dust

Means average braking torque during Decel to stop of a motor.

Refer to Chapter 16 of user’s manual for DB resistor specification.

 




















  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: