6SL3217-0CE25-5UA0 Siemens Inverter V10 series New in boxSiemens Inverter 6SL3217-0CE25-5UA0
Product Description:
The SINAMICS V10 inverters are designed for controlling the speed of three phrase AC asynchronous squirrel cage motors. The models available range from the 0.55 kW three phase output power to the 22 kW three phase output power.
The inverters are microprocessor-controlled and use state-of-the-art IGBT technology. A special pulse-width modulation method with selectable pulse frequency permits quiet motor operation. Comprehensive protective functions provide excellent inverter and motor protection.
SINAMICS V10 with its default factory settings is ideal for a large range of simple motor control applications. It can also be used for more advanced motor control operations via its comprehensive parameter lists. In addition, it's suitable for use in "stand-alone" applications or being integrated into "Automation Systems" via input/output signals.
SINAMICS V10-1 AC-DRIVE, WITHOUT FILTER 3AC380V -15/+20% 48-52HZ OUTPUT 1,5KW OVERLOAD 150% 60S,100% 240S, CYCLE 300S AMBIENT TEMP 0 TO +50 DEG C 230 X 140 X 155 (HXWXD), FSA PROTECTION IP21 WITH BOP.
Specifications:
Order no.: 6SL3217-0CE Frame Size A Frame Size B Frame Size C Frame Size D
15-5 UA0 17-5 UA0 21-1 UA0 21-5 UA0 22-2 UA0 23-0 UA0 24-0 UA0 25-5 UA0 27-5 UA0 31-1 UA0 31-5 UA0 31-8 UA0 32-2 UA0
Display 5-digit, 7-segment LCD
Configurable motor 3-ph AC asynchronous squirrel cage motors
Electrical data
Rated motor power (kW) 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5 22
Rated input current (A) 1.9 2.4 3.7 5.2 6.5 8.6 11.6 15.6 22.0 32.3 38.5 47.1 56.3
Rated output current (A) 1.7 2.2 3.1 4.1 5.9 7.7 10.2 13.2 18.4 26.0 32.0 38.0 45.0
Output current deratings with pulse freq. changes Pulse freq. Range: 2 to 16 kHz; Default PWM: 4 kHz The max. continuous output current (A) at different pulse frequencies is shown as below: 1)
2 kHz 1.7 2.2 3.1 4.1 5.9 7.7 10.2 13.2 18.4 26.0 32.0 38.0 45.0
4 kHz 1.7 2.2 3.1 4.1 5.9 7.7 10.2 13.2 18.4 26.0 32.0 38.0 45.0
6 kHz 1.7 2.2 3.1 4.1 5.9 7.7 10.2 13.2 18.4 26.0 27.2 32.3 38.3
8 kHz 1.7 2.2 2.7 2.7 5.1 5.1 6.7 13.2 13.2 17.9 22.4 26.6 31.5
10 kHz 1.7 2.2 2.7 2.7 5.1 5.1 6.7 13.2 13.2 17.9 19.2 22.8 27.0
12 kHz 1.7 1.6 1.6 1.6 3.6 3.6 4.8 9.6 9.6 13.5 16.0 19.0 23.2
14 kHz 1.7 1.6 1.6 1.6 3.6 3.6 4.8 9.6 9.6 13.5 14.4 17.1 20.3
16 kHz 1.1 1.1 1.1 1.1 2.6 2.6 3.6 7.5 7.5 10.4 12.8 15.2 18.0
Mains operating voltage Rated: 3 AC 380 V (tolerance: - 15 % to + 20 %) Full voltage range: 323 V to 456 V, inverter without derating output current From - 15 % to - 20 %, 50 % derating for 5 minutes every 60 minutes.
Mains input frequency Rated: 50 Hz (tolerance - 3% to + 3%) Full frequency range: 48 Hz to 52 Hz
Mains system TNC, TNS, TT or IT systems 2)
Output frequency 0 Hz to 300 Hz If output frequency is less than 2 Hz for over 0.5 s, the default switching frequency shall be reduced to half of the default value.
Power factor 0.95
Inverter efficiency 96 % to 97 %
Overload capability 150% of the rated output current for 60 s; Cycle time: 300 s
Overvoltage category Mains input terminals (L1, L2, L3): III Digital output terminals (DO1) 3): II, max. 250 V
Pollution class II
Control method Linear V/f control; Quadratic V/f control; V/f control with Flux Current Control (FCC)
Fixed frequency 3, programmable
Skip frequency: 1
Setpoint resolution 0.1 Hz digital input 10-bit analog input (motor potentiometer 0.1 Hz)
Digital inputs 3, programmable (isolated)
Analog input 1, programmable (0 to 10 V or 0 to 20 mA)
Relay output 1, programmable, 250 V AC / max. 2 A (inductive), 30 V DC / max. 5 A (resistive)
Analog output 1, programmable (0 to 10 V or 0 to 20 mA, max. 500 ohm in current mode / min. 5000 ohm in voltage mode)
Braking DC braking, compound braking
Protection functions ? Short circuit protection ? Over-current protection ? Over-/Under-voltage protection ? Inverter and motor overt-temperature protections ? Ground fault protection ? Stall prevention ? Motor blocking protection ? Parameter interlock
Motor cable length Max. 30 m, shielded / Max. 50 m unshielded
Mechanical data
Outline dimensions (mm) H 230 260 331 401
W 140 150 218 260
D 4) 155 (138 ) 159 (142) 203 (186) 223 (210)
Note: The outline dimensions of the operator panel are 91 x 97 x 30 (H x W x D, in mm).
Weight (kg) 5) 2.2 2.9 8.1 10.1
Mounting method For inverter with assembled operator panel:
• Wall mounting without optional mounting kit
• Push-through mounting with optional mounting kit For removable operator panel:
• Mounted to cabinet door
Cooling method Natural cooling Forced cooling Forced cooling Forced cooling
Environmental conditions
Ambient temperature Operation Transport & storage 0 °C to 50 °C without power derating (100 % load) 50 °C to 60 °C with power derating -40 °C to + 70 °C
Relative humidity 5 to 95 %, without condensation
Contamination level Chemical gases: 3C2 and solid particles: 3S2, according to IEC60721-3-3
Vibration resistance < 1 G (9.81 m/s2) acceleration
Atmospheric pressure 0 to 1, 000 m above sea level: without power derating 1,000 m to 4,000 m: with power derating
Protection class IP21 (excluding all input/output terminals)
Standards CE mark, in accordance with Low-Voltage Directive 2006/95/EC; China national standards GB12668 and GB/T12668 series standards concerned
Notes:
Unless otherwise specified, the output current indicated refers to the value that can be reached when the ambient temperature is at 50 °C.
2) Can be operated on TNC, TNS, TT or IT, excluding three-phase three-wire systems unearthed or corner-earthed; Can also be operated on the three-phase three-wire systems unearthed or corner-earthed if an appropriate transformer or a separately derived source that normally supplies an unearthed system is installed on the mains system.
3) The digital output terminals are at a dangerously high voltage when Non-SELV control voltage is applied. Use only approved double insulated cable for supply connection with nominal cross-section area of at least 0.75 mm2/ 300 V / 75 °C and protected by max. 6A external fuse, type gG approved based on IEC 60269.
4) The depth value in brackets refers to the value of the inverter without the operator panel.
5) The weight here includes the weight of the operator panel.
6) If the mounting altitude reaches 2000 m or above, it's necessary to mount an isolating transformer.
7) The permissible output current is specified in % of the rated output current. The permissible input voltage is specified in % of the max. mains input voltage.
8) The protection class of all input/output terminals is IP00.