Your Position: Home > Control System > Module > Kinco > PLC CPU AC220V 8 DI 3 DO transistor or relay KINCO K304-14AX New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

PLC CPU AC220V 8 DI 3 DO transistor or relay KINCO K304-14AX New

prevnext

PLC CPU AC220V 8 DI 3 DO transistor or relay   KINCO K304-14AX New
  • NO.: AC220V
  • Weight: 1.500 KG
  • Market price: $ 389.4
  • Shop price: $ 118.0
  • Goods click count: 528
  • Total:
  • Quantity:
Add to cart collect
  

Description

Kinco K3 PLC CPU Module CPU304 Series K304-14AX NIB 8 Digital Inputs 3 Transistor & Relay Outputs AC85~265V New

If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574- 88333153
We will quote you our best price to you in 24hours.

Specifications:

Model

K304

K304-14AT

K304-14AR

K304-14AX

Technical Specification

CPU

16-Bit Industrial

Execution Speed

Typical Bool Instruction Time: <1μS

Word Operation Time: <96μS

Arithmetic Operation Time for Integers: <130μS

Arithmetic Operation Time for Floating Points: <300μS

DI Points

8XDC24V

DO Points

6XDC24V

6XRelay

3XDC24V+3XRelay

User Program Memory

EEPROM, 8KB

Program Backup

Permanent Storage, Without the Need of Battery//1000 Instructions

Memory Area

Variable Storage Area (V Area): 2KB

System Storage Area (SM Area): 300 Bytes

Internal Storage Area (M Area): 32 Bytes

Data Retention Characteristic

Configure with the Programming Software: V Area, C (Counter) Area

Retention Mode and Period

Adopt super capacitors and support a retention period of not less than 144 hours upon power failure under normal temperature.

Data Backup Characteristic

Perform Backup Operations VB1648 ~ VB1775 According to User Instructions, 128 Bytes in Total

Backup Mode and Time

EEPROM (Writing Operation for 1 Million Times) Permanent Backup

Floating Points

Supported; the Whole V Area can be Used for Floating Points

Programming Language Supported

Ladder Drawing (LD), Instruction List (IL)

Instruction Set

Basic Instructions: 55; Expansion Instructions: 251

PasswordProtection

Yes

Max I/O Number

Digital Data: 14 in Total (DI8, DO6);

Analog Data: None

Counter

64

Operation Mode of Counter

Addition, Subtraction

Counter Range

-32768~32767

Counting Value Retention Function

Yes

Timer

64

1 ms time Base: 4

10 ms Time Base: 16

100 ms Time Base: 44

High speed counter

2 Single/Dual-Phase High-Speed Counters

Where, Single-Phase Counter with a Maximum Frequency of 20KHz

Dual-Phase Counter with a Maximum Frequency of 10KHz

Pulse output

2, PTO (Pulse Train Output)/PWM (Pulse Width Modulation Output);

Maximum Output Frequency: 20 KHz(Note: the elay output CPU does not have high speed pluse function)

Analog Potentiometer

-

Interrupt function

Timing Interruption: 2, 1ms Resolution;

Timer Interruption: T2/T3, 1ms Resolution;

Edge Interruption: 4, Rising Edge or Falling Edge Optional;

High-Speed Interruption, Communication Interruption

Real-time cholck

0

Number of Connectable Expansion Modules

-

COM Port

1, RS232 or RS485;

Supported Working Modes: Programming, Modbus-RTU (Slave), Free Protocol

Equipment Connected with COM Port

RS232/RS485: PC (For Programming), Third-Party HMI Panel, Third-Party Serial Communication Equipment (For Example, Instruments, Bar Code Reader, etc.)

Input Power Supply

AC85~265V

Sensor Load Power Supply

DC24V, Max. 300 mA

Dimensions (L*W*H)

97X114X70mm

 






  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: