FX3U-4AD module 4AI Mitsubishi

prevnext

FX3U-4AD module 4AI Mitsubishi
  • Market price: $ 514.8
  • Shop price: $ 156.0
  • Goods click count: 550
  • Total:
  • Quantity:
Add to cart collect
  

Description

FX3U-4AD Mitsubishi PLC Special Function Block Original Brand NEW


Introduction

The FX3U-4AD special function block for analog input converts four analog input values (voltage, current) to digital values and transfers those digital values to the PLC main unit.

 

 

Applicable PLC

Model name

Applicability

FX3U Series PLC

Ver. 2.20 or later (from first production)

Up to 8 blocks can be extended

FX3UC Series

PLC*1

Ver. 1.30 or later (from the production manufactured in August,

2004 with SER No. 48…………)

Up to 8 blocks can be extended*2

The version number can be checked by monitoring D8001 as the last three digits indicate it.

*1 An FX2NC-CNV-IF or FX3UC-1PS-5V is necessary to connect the FX3U-4AD with the FX3UC PLC.

*2 Up to 7 units can be connected to the FX3UC-32MT-LT(-2) PLC.

Power Supply Specifications

Item

Specification

A/D conversion

circuit driving power

24V DC +-10%, 90mA

(24V DC power is supplied from the power connector.)

CPU driving power

5V DC, 110mA

(5V DC power is supplied from the internal power supply of main unit.)

Performance Specifications

Item 

Description

Voltage input

Current input

Analog input

range

-10 to +10V DC

(Input resistance: 200 k ohm)

-20 to +20mA, 4 to 20mA DC

(Input resistance: 250 ohm)

Offset*1

10 to +9V*2

20 to +17mA*3

Gain*1

-9 to +10V*2

-17 to +30mA*3

Maximum absolute input

+-15V

+-30mA

Digital output

With sign, 16bits, binary

With sign, 15bits, binary

Resolution

0.32mV (20V/64000)

1.25uA (40mA/32000)

Total accuracy

+-0.3% (+-60mV) for full scale

of 20V (when ambient temperature is 25°C±5°C)

+-0.5% (+-100mV) for full scale

of 20V (when ambient

temperature is 0°C to 55°C)

+-0.5% (+-200µA) for full scale

of 40mA (when ambient

temperature is 25°C+-5°C and

a current of -20 mA to +20 mA

is input)

Same when input is 4mA to

20mA

+-1.0% (+-400uA) for full scale

of 40mA (when ambient

temperature is 25°C±5°C and

a current of -20 mA to +20 mA

is input)

Same when input is 4mA to

20mA

A/D conversion time

500µs × number of selected channels

(If channels use the digital filter(s): 5ms × number of selected

channels)

Insulation

method

The photo-coupler insulates the analog input area from the PLC.

The DC-DC converter insulates the analog input area from the power supply unit.

Channels are not insulated from each other.

*1 Change the offset and gain values to change the input characteristics. However, the resolution doesn’t change even when the offset and gain values change.

When the analog value direct indication is enabled in the input mode 2, 5, or 8, the offset value and the gain value don’t change.

*2 The offset and the gain should satisfy the following condition:1V <= (Gain - Offset)

*3 The offset and the gain should satisfy the following condition: 3 mA <=(Gain - Offset) <= 30 mA

*4 The input characteristics vary depending on the input mode to be used.

External Dimensions and Part Names


  