No comment |
>
Motion Control System >
AC Servo System >
LiChuan >
3PH 220V 130mm 10NM 1KW 1000RPM 4.5A AC servo motor drive Kit 3M Cable LCMT-10M02NB-130M10010B+LCDB2-102002-MB13323PH 220V 130mm 10NM 1KW 1000RPM 4.5A AC servo motor drive Kit 3M Cable
Package:
1. motor LCMT-10M02NB-130M10010B
2. drive LCDB2-102002-MB1332
3. 3M Encoder cable& Power Cable
Specification motor:
Motor model | LCMT10L02-130M04025 | LCMT13L02-130M05025 | LCMT15L02-130M06025 | LCMT20L02-130M07725 | LCMT10M02-130M10010 |
rated power | 1.0 KW | 1.3 KW | 1.5 KW | 2.0 KW | 1.0 KW |
rated line voltage | 220 V | 220 V | 220 V | 220 V | 220 V |
rated line current | 4 A | 5 A | 6 A | 7.5 A | 4.5 A |
rated speed | 2500 rpm | 2500 rpm | 2500 rpm | 2500 rpm | 1000 rpm |
rated torque | 4 NM | 5 NM | 6 NM | 7.7 NM | 10 NM |
peak torque | 12NM | 16 NM | 18 NM | 22 NM | 20 NM |
Counter emf | 72 V/1000r/min | 68 V/1000r/min | 65 V/1000r/min | 68 V/1000r/min | 140 V/1000r/min |
torque coefficient | 1.0 (nm/A) | 1.0 (nm/A) | 1.0 (nm/A) | 1.03 (nm/A) | 2.2 (nm/A) |
rotor inertia | 0.85×10-3 kg.m2 | 1.06×10-3 kg.m2 | 1.26×10-3 kg.m2 | 1.53×10-3 kg.m2 | 1.94×10-3 kg.m2 |
coil resistance(Ω) | 2.76 | 1.84 | 1.21 | 1.01 | 2.7 |
coil inductance(mH) | 6.42 | 4.9 | 3.87 | 2.94 | 8.8 |
electrical time constance | 2.32 Ms | 2.66 Ms | 3.26 Ms | 3.8 Ms | 3.26 Ms |
Weight | 7.7kg | 8.2 kg | 8.9 kg | 10 kg | 11.5 kg |
Encoder | 2500ppr | ||||
motor insulation | Bclass (130 centigrade degree) | ||||
protection class | IP 66 |
Drive Specification
Feature:
position/speed all-in-one machine
1) capacity range:0.12kw~2kw
2) input voltage: AC200V~230V,single/three phase input
3) position/speed control/ Torque control mode
4) Built-in uniaxial orientation control function;8 position speed control function; equal to a simple PLC
5) Support MODBUS communication controlRS-485&RS-422&RS-232).ASCII&RTU communication protocol.
6) support encoder type: 2500ppr; Increase the terminal blocks for brake resistor.
7) Increase the gain automatic tuning function for Semi-automatic and fully automatic.
LCDA series | 02 | 04 | 05 | 07 | 08 | 10 | 12 | 13 | 15 | 18 | 20 | 23 | 26 | 28 | |||
Power | phase/Voltage | single-phase 220VAC | single/three phase 220VAC | ||||||||||||||
allowed voltage regulatiion | 170~255VAC | ||||||||||||||||
Allowedfrequency regulation | 50/60 Hz±5% | ||||||||||||||||
cooling way | natural cooling | fan cooling | |||||||||||||||
encoder/feedback | 2500ppr/10000pulse/rad | ||||||||||||||||
the primary loop control mode | SVPWM control | ||||||||||||||||
manipulation mode | manual/auto | ||||||||||||||||
retrogradation resistance | Built-in | ||||||||||||||||
Position control mode | Maximum input pulse frequency | Poor transport:500kpps open transport:200kpps | |||||||||||||||
pulse instruction mode | pulse+symbol:A+B phase; CCW pulse +CW pulse | ||||||||||||||||
instruction control mode | external pulse control | ||||||||||||||||
instruction smooth mode | low pulse smoothing filter | ||||||||||||||||
electronic gear ratio | electronic gear N/M time N:1~3276/M:1:32767(1/127 | ||||||||||||||||
torque limitation | parameter setting way | ||||||||||||||||
feed-forward compensation | parameter setting way | ||||||||||||||||
Speed control mode | Analogy Input | voltage range | 0~10VDC | ||||||||||||||
input resistance | 20kΩ | ||||||||||||||||
time constant | 2.2μs
| ||||||||||||||||
Overload allowed rehearsal | 200% rated output 8 s | ||||||||||||||||
instruction control mode | external analogy control/internal temporary control | ||||||||||||||||
instruction smooth mode | low pass and S curve smoothing filter | ||||||||||||||||
torque limitation | parameter setting mode | ||||||||||||||||
bandwidth | up to 250HZ | ||||||||||||||||
speed calibration ratio | external load rated change(0~100%)max 0.01% | ||||||||||||||||
power ±10% change max 0.01% | |||||||||||||||||
environment temperature(0~50 centigrade )max 0.01% | |||||||||||||||||
Torque control mode | Input | Servo start, abnormal reset ,switch gain clear pulse counting register emergency stop down or counterclockwise running limit is prohibited | |||||||||||||||
Internal register control command, speed limit orders, location speed mixed mode command options, speed mixed mode command options, position torque mixed mode command options | |||||||||||||||||
Output | A/B/Z differential output(line drive)/Z phase open collector | ||||||||||||||||
Servo start preparation, servo, zero speed detection, speed, position arrived, the torque limit | |||||||||||||||||
| Electromagnetic brake control of servo alarm output, output, complete | ||||||||||||||||
Protection | Over current, over voltage, under voltage, overheating, load, velocity error is too large, the position error is too large, detector is unusual, abnormal retrogradation, communication is unusual, abnormal memory | ||||||||||||||||
Communication interface | RS-232/RS485 RS422 ACSII RTU |
3PH 220V 130mm 10NM 1KW 1000RPM 4.5A AC servo motor drive Kit 3M Cable
Package:
1. motor LCMT-10M02NB-130M10010B
2. drive LCDB2-102002-MB1332
3. 3M Encoder cable& Power Cable
Specification motor:
Motor model
LCMT10L02-130M04025
LCMT13L02-130M05025
LCMT15L02-130M06025
LCMT20L02-130M07725
LCMT10M02-130M10010
rated power
1.0 KW
1.3 KW
1.5 KW
2.0 KW
1.0 KW
rated line voltage
220 V
220 V
220 V
220 V
220 V
rated line current
4 A
5 A
6 A
7.5 A
4.5 A
rated speed
2500 rpm
2500 rpm
2500 rpm
2500 rpm
1000 rpm
rated torque
4 NM
5 NM
6 NM
7.7 NM
10 NM
peak torque
12NM
16 NM
18 NM
22 NM
20 NM
Counter emf
72
V/1000r/min
68
V/1000r/min
65
V/1000r/min
68
V/1000r/min
140 V/1000r/min
torque coefficient
1.0
(nm/A)
1.0
(nm/A)
1.0
(nm/A)
1.03
(nm/A)
2.2
(nm/A)
rotor inertia
0.85×10-3
kg.m2
1.06×10-3
kg.m2
1.26×10-3
kg.m2
1.53×10-3
kg.m2
1.94×10-3
kg.m2
coil resistance(Ω)
2.76
1.84
1.21
1.01
2.7
coil inductance(mH)
6.42
4.9
3.87
2.94
8.8
electrical time constance
2.32 Ms
2.66 Ms
3.26 Ms
3.8 Ms
3.26 Ms
Weight
7.7kg
8.2 kg
8.9 kg
10 kg
11.5 kg
Encoder
2500ppr
motor insulation
Bclass (130 centigrade degree)
protection class
IP 66
Drive Specification
Feature:
position/speed all-in-one machine
1) capacity range:0.12kw~2kw
2) input voltage: AC200V~230V,single/three phase input
3) position/speed control/ Torque control mode
4) Built-in uniaxial orientation control function;8 position speed control function; equal to a simple PLC
5) Support MODBUS communication controlRS-485&RS-422&RS-232).ASCII&RTU communication protocol.
6) support encoder type: 2500ppr; Increase the terminal blocks for brake resistor.
7) Increase the gain automatic tuning function for Semi-automatic and fully automatic.
LCDA series
02
04
05
07
08
10
12
13
15
18
20
23
26
28
Power
phase/Voltage
single-phase 220VAC
single/three phase 220VAC
allowed voltage regulatiion
170~255VAC
Allowedfrequency regulation
50/60 Hz±5%
cooling way
natural cooling
fan cooling
encoder/feedback
2500ppr/10000pulse/rad
the primary loop control mode
SVPWM control
manipulation mode
manual/auto
retrogradation resistance
Built-in
Position control mode
Maximum input pulse frequency
Poor transport:500kpps open transport:200kpps
pulse instruction mode
pulse+symbol:A+B phase; CCW pulse +CW pulse
instruction control mode
external pulse control
instruction smooth mode
low pulse smoothing filter
electronic gear ratio
electronic gear N/M time N:1~3276/M:1:32767(1/127
torque limitation
parameter setting way
feed-forward compensation
parameter setting way
Speed control mode
Analogy Input
voltage range
0~10VDC
input resistance
20kΩ
time constant
2.2μs
Overload allowed rehearsal
200% rated output 8 s
instruction control mode
external analogy control/internal temporary control
instruction smooth mode
low pass and S curve smoothing filter
torque limitation
parameter setting mode
bandwidth
up to 250HZ
speed calibration ratio
external load rated change(0~100%)max 0.01%
power ±10% change max 0.01%
environment temperature(0~50 centigrade )max 0.01%
Torque control mode
Input
Servo start, abnormal reset ,switch gain clear pulse counting register emergency stop down or counterclockwise running limit is prohibited
Internal register control command, speed limit orders, location speed mixed mode command options, speed mixed mode command options, position torque mixed mode command options
Output
A/B/Z differential output(line drive)/Z phase open collector
Servo start preparation, servo, zero speed detection, speed, position arrived, the torque limit
Electromagnetic brake control of servo alarm output, output, complete
Protection
Over current, over voltage, under voltage, overheating, load, velocity error is too large, the position error is too large, detector is unusual, abnormal retrogradation, communication is unusual, abnormal memory
Communication interface
RS-232/RS485 RS422 ACSII RTU
No comment |