No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
FA12-4NA FEILING Inductance type proximity switch NewFEILING Inductance type proximity switch FA12-4NA
Products Description:
FEILING FA12 Series Inductance type proximity switch.
Specifications:
Installation Mode | Buried type | Non submerged | |||
Detection Distance | 2mm | 4mm | |||
AC90-250V | Two-wire system | NO | FA12-M2KA | FA12-4KA | |
NC | FA12-M2KB | FA12-4KB | |||
Three-wire system | NO+NC | ? | ? | ||
Ralay output four lines | NO+NC | ? | ? | ||
Ralay output five lines | NO+NC | ? | ? | ||
DC6-36V | NPN | NO | FA12-M2NA | FA12-4NA | |
NC | FA12-M2NB | FA12-4NB | |||
NO+NC | FA12-M2NC | FA12-4NC | |||
PNP | NO | FA12-M2PA | FA12-4PA | ||
NC | FA12-M2PB | FA12-4PB | |||
NO+NC | FA12-M2PC | FA12-4PC | |||
Two-wire system | NO | FA12-M2LA | FA12-4LA | ||
NC | FA12-M2LB | FA12-4LB | |||
Output Voltage drop DC/AC | AC<8V ,DC three line <1.5V,DC two line <4V | ||||
Output Current | 300mA /1A?2A DC three line200mA DC two line 50mA | ||||
Repeat Accuracy | ≤10% | ||||
Current consumption | <10mA | ||||
Response frequency | DC 800Hz,AC 25Hz | DC 400Hz,AC 25Hz | |||
Shell material | Metal/plasticABS | ||||
Set the distance | 0-1.6mm | 0-3.2mm | |||
Standard for detection of objects | 14×14×1(Iron) | ||||
Working environment temperature | -20?~+55? | ||||
Connection mode | 1.5m PVC Cable | ||||
Protection grade | IP67 |
FA12-4NA FEILING Inductance type proximity switch NewFEILING Inductance type proximity switch FA12-4NA
Products Description:
FEILING FA12 Series Inductance type proximity switch.
Specifications:
Installation Mode
Buried type
Non submerged
Detection Distance
2mm
4mm
AC90-250V
Two-wire system
NO
FA12-M2KA
FA12-4KA
NC
FA12-M2KB
FA12-4KB
Three-wire system
NO+NC
?
?
Ralay output four lines
NO+NC
?
?
Ralay output five lines
NO+NC
?
?
DC6-36V
NPN
NO
FA12-M2NA
FA12-4NA
NC
FA12-M2NB
FA12-4NB
NO+NC
FA12-M2NC
FA12-4NC
PNP
NO
FA12-M2PA
FA12-4PA
NC
FA12-M2PB
FA12-4PB
NO+NC
FA12-M2PC
FA12-4PC
Two-wire system
NO
FA12-M2LA
FA12-4LA
NC
FA12-M2LB
FA12-4LB
Output Voltage drop DC/AC
AC<8V ,DC three line <1.5V,DC two line <4V
Output Current
300mA /1A?2A DC three line200mA DC two line 50mA
Repeat Accuracy
≤10%
Current consumption
<10mA
Response frequency
DC 800Hz,AC 25Hz
DC 400Hz,AC 25Hz
Shell material
Metal/plasticABS
Set the distance
0-1.6mm
0-3.2mm
Standard for detection of objects
14×14×1(Iron)
Working environment temperature
-20?~+55?
Connection mode
1.5m PVC Cable
Protection grade
IP67
No comment |