No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
VB-4241 Travel Switch NEWVB-4241 OMRON Travel Switch NEWOMRON Travel Switch VB-4241
Product Description:
Used for the sequential control of a variety of engineering machines and belt conveyor lines.
Built-in oil filter shuts out oil and water.
Approved by EN, IEC (Ground terminal models only.) and CCC (Chinese standard). Ask your OMRON representative for information on approved models.
Ground terminal models bear the CE mark.
Specifications:
Degree of protection
IP67
Durability *
Mechanical
5,000,000 operations min.
Electrical
300,000 operations min. (10 A at 250 VAC, resistive load)
Operating speed
0.1 mm to 0.5 m/s
Operating
Mechanical
120 operations min.
frequency
Electrical
30 operations min.
Rated frequency
50/60 Hz (AC)
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
15 mΩ max. (initial value)
Dielectric
Between terminals of same polarity
1,000 VAC/Uimp 4,000 VAC
strength
Between current-carrying metal parts
1,500 VAC/Uimp 4,000 VAC
and ground
Between each terminal and non-
1,500 VAC/Uimp 4,000 VAC
current-carrying metal part
Between terminals of different polarity
Uimp 4 kV (EN60947-5-1)
Rated insulation voltage (Ui)
300 VAC (EN60947-5-1)
Switching overvoltage
1,000 V max. (EN60947-5-1)
Pollution degree (operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD)
10 A fuse type gG or gI (IEC269)
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe)
5 A, 0.5 A (EN60947-5-1)
Protection against electric shock
Insulation class I (Use the grounding terminal or ground on the machine side.)
Vibration
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
resistance
Shock
Destruction
1,000 m/s2 min.
resistance
Malfunction
200 m/s2 min.
Ambient operating temperature
-10°C to 80°C (with no icing)
Ambient operating humidity
35% to 95%
Weight
Approx. 580 g (in the case of VB-4211)
Note:
*The values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments.
No comment |