No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
F&C Light curtain FGM series area sensors FGM40-06If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:service@plcage.com
Tel:0086-574- 88333153
We will quote you our best price to you in 24hours.
Specifications:
Transmissive type Test type | ||||||||
Model | NPN open-collector output (standard type) | FGM20-08 FGM20-12 FGM20-16 | FGM20-20 FGM20-24 FGM20-28 | FGM20-32 FGM20-36 FGM20-40 | FGM20-44 FGM20-48 FGM40-02 FGM40-04 FGM40-06 FGM40-08 | FGM40-10 FGM40-12 FGM40-14 | FGM40-16 FGM40-18 FGM40-20 | FGM40-22 FGM40-24 |
PNP open-collector output | FGM20-08P FGM20-12P FGM20-16P | FGM20-20P FGM20-24P FGM20-28P | FGM20-32P FGM20-36P FGM20-40P | FGM20-44P FGM20-48P FGM40-02P FGM40-04P FGM40-06P FGM40-08P | FGM40-10P FGM40-12P FGM40-14P | FGM40-16P FGM40-18P FGM40-20P | FGM40-44P FGM40-48P | |
Overall dimension | Fiber optic space: 20mm Fiber optic space: 40mm | |||||||
Scanning distance (width) | 0.2~3m (usually use 2m) | |||||||
Scanning object | Nonstransparent object Min. dimension: Φ20mm | |||||||
Optical axis width | 20mm 40mm | |||||||
Optical axis | 8~48PCS 4~24PCS | |||||||
Scanning width | 140~940PCS 120~920PCS | |||||||
Angle of direction | Scanning distance: ±3? above 2m | |||||||
Power voltage | 12~24VDC 10%±(Ripple P-P: 10% Max) | |||||||
Protection circuit | Circuit reverse connecting protection | |||||||
Current consumption | Transmitter: max. 80mA, receiver: max. 80mA | |||||||
Control output | NPN open-collector output: Load voltage max. 30VDC Load current max. 100mA Residual voltage max. 1VDC PNP open-collector output: Output voltage max. 100VDC Load current min. Power supply 2.5VDC | |||||||
Operating mode | Light ON only | |||||||
Short circuit protection | Build-in | |||||||
Response time | Min. 12ms | |||||||
Light source | Infrared light | |||||||
Simultaneous mode | Simultanous mode | |||||||
Self-diagnostic | Light source inspection, transmitter/receiver luminescent circuit and output circuit |
Applications:
*The uncertain path of falling objects detected.
*Check roll.
*Check option to prevent errors.
F&C Light curtain FGM series area sensors FGM40-06If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:service@plcage.com
Tel:0086-574- 88333153
We will quote you our best price to you in 24hours.Specifications:
Transmissive type
Test type
Model
NPN open-collector output (standard type)
FGM20-08
FGM20-12
FGM20-16
FGM20-20
FGM20-24
FGM20-28
FGM20-32
FGM20-36
FGM20-40
FGM20-44
FGM20-48
FGM40-02
FGM40-04
FGM40-06
FGM40-08
FGM40-10
FGM40-12
FGM40-14
FGM40-16
FGM40-18
FGM40-20
FGM40-22
FGM40-24
PNP open-collector output
FGM20-08P
FGM20-12P
FGM20-16P
FGM20-20P
FGM20-24P
FGM20-28P
FGM20-32P
FGM20-36P
FGM20-40P
FGM20-44P
FGM20-48P
FGM40-02P
FGM40-04P
FGM40-06P
FGM40-08P
FGM40-10P
FGM40-12P
FGM40-14P
FGM40-16P
FGM40-18P
FGM40-20P
FGM40-44P
FGM40-48P
Overall dimension
Fiber optic space: 20mm Fiber optic space: 40mm
Scanning distance (width)
0.2~3m (usually use 2m)
Scanning object
Nonstransparent object Min. dimension: Φ20mm
Optical axis width
20mm 40mm
Optical axis
8~48PCS 4~24PCS
Scanning width
140~940PCS 120~920PCS
Angle of direction
Scanning distance: ±3? above 2m
Power voltage
12~24VDC 10%±(Ripple P-P: 10% Max)
Protection circuit
Circuit reverse connecting protection
Current consumption
Transmitter: max. 80mA, receiver: max. 80mA
Control output
NPN open-collector output: Load voltage max. 30VDC Load current max. 100mA
Residual voltage max. 1VDC
PNP open-collector output: Output voltage max. 100VDC Load current min.
Power supply 2.5VDC
Operating mode
Light ON only
Short circuit protection
Build-in
Response time
Min. 12ms
Light source
Infrared light
Simultaneous mode
Simultanous mode
Self-diagnostic
Light source inspection, transmitter/receiver luminescent circuit and output circuit
Applications:
*The uncertain path of falling objects detected.
*Check roll.
*Check option to prevent errors.
No comment |