D4JL-4NFA-C7-01 Safety Door Switch NEWD4JL-4NFA-C7-01 OMRON Safety Door Switch NEWOMRON Safety Door Switch D4JL-4NFA-C7-01
Product Description:
World's Top* Holding Force of 3,000 N
Specifications:
Degree of protection *1
IP67 (EN60947-5-1)
Durability *2
Mechanical
1,000,000 operations min. (trapped key: 10,000 operations min., rear release button: 3,000 operations min.)
Electrical
500,000 operations min. (3 A resistive load at 250 VAC) *3
Operating speed
0.05 to 0.5 m/s
Operating frequency
30 operations/minute max.
Direct opening force *4
60 N min. (EN60947-5-1)
Direct opening travel *4
15 mm min. (EN60947-5-1)
Holding force *5
3,000 N min.
Contact resistance
25 mΩ max. (per contact)
Minimum applicable load *6
1 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui)
300 V (EN60947-5-1)
Rated frequency
50/60 Hz
Protection against electric shock
Class II (double insulation)
Pollution degree
3 (EN60947-5-1)
(operating environment)
Impulse
Between terminals
2.5 kV
withstand
of same polarity
voltage
Between terminals
4 kV
(EN60947-5-1)
of different polarity
Between other
6 kV
terminals and
non-current carrying
metallic parts
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact gap
2 × 2 mm min.
Vibration
Malfunction
10 to 55 Hz, 0.75 mm single amplitude
resistance
Shock resistance
Destruction
1,000 m/s 2 min.
Malfunction
80 m/s 2 min.
Conditional short-circuit current
100 A (EN60947-5-1) *7
Conventional free air thermal current (Ith)
10 A (between terminals 12 and 41),
3 A (between all other terminals) (EN60947-5-1)
Ambient operating temperature
-10 to +55°C (with no icing)
Ambient operating humidity
95% max.
Weight
Approx. 650 g (D4JL-4NFA-C7-01)
Note:
*1.The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4JL in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2.The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For further conditions, consult your OMRON sales representative.
*3.Do not pass a 3 A, 250 VAC load through more than two circuits.
*4.These figures are minimum requirements for safe operation.
*5.This figure is based on the GS-ET-19 evaluation method.
*6.This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand.
*7.Use a 10 A fuse type gI or gG that conforms to IEC 60269 as a short-circuit protection device.