S8JX-G15024CD OMRON Switching Power Supply NEW

Product Description:

Flexible Selection of Reliability and Ease of Operation with the S8JX. New Models with Harmonic Current Suppression for a Broader Lineup.

Specifications:

Input specification

100 to 240 V input

Power ratings *1

15 W

35 W

Efficiency

68% min.

73% min.

Input

Voltage *2

100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *9)

Frequency *2

50/60 Hz (47 to 450 Hz)

Current *3

100 V input

0.4 A max.

1 A max.

200 V input

0.25 A max.

0.6 A max.

Harmonic current emissions

---

Leakage

100 V input

0.5 mA max.

current *3

200 V input

1 mA max.

Inrush current

100 V input

20 A max.

(for a cold

start at 25 °C)

*3

200 V input

40 A max.

Output

Voltage adjustment range *5

- 10% to 15% (with V. ADJ) (48-V models: ± 10%)

*4

Ripple *3

2% (p-p) max.

 

Input variation influence

0.4% max. with AC input voltage

 

Load variation influence

0.8% max. (0 to 100% load, rated input voltage)

 

Temperature variation influence

0.05%/ ° C max. (at rated input and output)

 

Startup time

500 ms max. (up to 90% of output voltage at rated input and output)

 

Hold time *3

20 ms min.

Additional

Overload protection *6

105% to 175% of rated load current, voltage drop, intermittent, automatic reset

functions

Overvoltage protection *7

Yes

 

Overheat protection

No

 

Parallel operation

No (However, backup operation is possible; external diodes required.)

 

Series operation

Yes (For up to two Power Supplies; external diodes required.)

 

Protective circuit operation indicator

No

Other

Ambient operating temperature

Refer to the derating curve in Engineering Data on Data Sheet (with no icing or

condensation).

Storage temperature

- 25 to 65 ° C (with no icing or condensation)

Ambient operating humidity

25% to 85% (Storage humidity: 25% to 90%)

Dielectric strength

3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)

2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)

1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)

Insulation resistance

100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC

Vibration resistance

10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions

Shock resistance

150 m/s2 , 3 times each in ± X, ± Y, ± Z directions

Output indicator

Yes (Color: Green)

EMI

Conducted

Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9

Emissions

Radiated Emissions

Conforms to EN 55011 Group 1 Class A *9

EMS 

Electrostatic

Conforms to EN61000-4-2

Discharge

Radiated

Conforms to EN61000-4-3

Electromagnetic

Field

Electrical Fast

Conforms to EN61000-4-4

Transient/Burst

Surge

Conforms to EN61000-4-5

Conducted

Conforms to EN61000-4-6

Disturbance

Voltage Dips/

Conforms to EN61000-4-11

Short Interruptions

Approved standards *9

UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)

cUL Listed: CSA C22.2 No.107.1

cUR: CSA C22.2 No. 60950-1

EN/VDE: EN50178 (= VDE 0160) Over voltage category III, EN 60950-1 (= VDE 0805

Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514))

SEMI

SEMI F47-0200 (200-VAC input)

Weight *8

250 g max.

Input specification

100 to 240 V input

Power ratings *1

50 W

100 W

Efficiency

5 V Models

76% min.

76% min.

12 V Models

81% min.

81% min.

24 V Models

83% min.

83% min.

48 V Models

82% min.

83% min.

Input

Voltage *2

100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *9)

Frequency *2

50/60 Hz (47 to 450 Hz)

Current *3

100 V input

1.4 A max.

2.5 A max.

200 V input

0.8 A max.

1.5 A max.

Harmonic current emissions

---

Leakage

100 V input

0.5 mA max.

current *3

200 V input

1 mA max.

Inrush current

100 V input

20 A max.

(for a cold

start at 25 °C)

*3

200 V input

40 A max.

Output

Voltage adjustment range *5

- 10% to 15% (with V. ADJ) (48-V models: ± 10%)

*4

Ripple *3

2% (p-p) max.

 

Input variation influence

0.4% max. with AC input voltage

 

Load variation influence

0.8% max. (0 to 100% load, rated input voltage)

 

Temperature variation influence

0.05%/ ° C max. (at rated input and output)

 

Startup time

500 ms max. (up to 90% of output voltage at rated input and output)

 

Hold time *3

20 ms min.

Additional

Overload protection *6

105% to 175% of rated load current, voltage drop, intermittent, automatic reset

functions

Overvoltage protection *7

Yes

 

Overheat protection

No

 

Parallel operation

No (However, backup operation is possible; external diodes required.)

 

Series operation

Yes (For up to two Power Supplies; external diodes required.)

 

Protective circuit operation indicator

No

Other

Ambient operating temperature

Refer to the derating curve in Engineering Data on Data Sheet (with no icing or

condensation).

Storage temperature

- 25 to 65 ° C (with no icing or condensation)

Ambient operating humidity

25% to 85% (Storage humidity: 25% to 90%)

Dielectric strength

3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)

2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)

1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)

Insulation resistance

100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC

Vibration resistance

10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions

Shock resistance

150 m/s2 , 3 times each in ± X, ± Y, ± Z directions

Output indicator

Yes (Color: Green)

EMI

Conducted

Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9

Emissions

Radiated Emissions

Conforms to EN 55011 Group 1 Class A *9

EMS 

Electrostatic

Conforms to EN61000-4-2

Discharge

Radiated

Conforms to EN61000-4-3

Electromagnetic

Field

Electrical Fast

Conforms to EN61000-4-4

Transient/Burst

Surge

Conforms to EN61000-4-5

Conducted

Conforms to EN61000-4-6

Disturbance

Voltage Dips/Short

Conforms to EN61000-4-11

Interruptions

Approved standards *9

UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)

cUL Listed: CSA C22.2 No.107.1

cUR: CSA C22.2 No. 60950-1

EN/VDE: EN50178 (= VDE 0160) Over voltage category III, EN 60950-1 (= VDE 0805

Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514))

SEMI

SEMI F47-0200 (200-VAC input)

Weight *8

300 g max.

550 g max.

Input specification

100/200 V switchable

100 to 240 V input

Power ratings *1

150 W at 5 V

150 W at 12 V

150 W at 24 or 48 V

Efficiency

5 V Models

78% min.

---

---

12 V Models

---

79% min.

---

24 V Models

---

---

86% min.

48 V Models

---

---

85% min.

Input

Voltage *2

Switchable between 100 to 120 VAC

100 to 240 VAC

(allowable range: 85 to 132 VAC) and

(allowable range: 85 to 264 VAC,

200 to 240 VAC (allowable range: 170

80 to 370 VDC *9)

to 264 VAC).

 

Frequency *2

50/60 Hz (47 to 450 Hz)

Current *3

100 V input

3.5 A max.

3.6 A max.

3.5 A max.

200 V input

2.1 A max.

2.2 A max.

2.1 A max.

Harmonic current emissions

---

Leakage

100 V input

0.5 mA max.

current *3

200 V input

1 mA max.

Inrush current

100 V input

20 A max.

(for a cold

start at 25 °C)

*3

200 V input

40 A max.

Output

Voltage adjustment range *5

- 10% to 15% (with V. ADJ) (48-V models: ± 10%)

*4

Ripple *3

2% (p-p) max.

 

Input variation influence

0.4% max. (with AC input voltage)

 

Load variation influence

0.8% max. (0 to 100% load, rated input voltage)

 

Temperature variation influence

0.05%/ ° C max. (at rated input and output)

 

Startup time

500 ms max. (up to 90% of output voltage at rated input and output)

 

Hold time *3

20 ms min.

Additional

Overload protection *6

105% to 175% of rated load current,

105% to 175% of rated load current,

functions

voltage drop, automatic reset

voltage drop, intermittent, automatic

 

 

reset

 

Overvoltage protection *7

Yes

 

Overheat protection

No

 

Parallel operation

No (However, backup operation is possible; external diodes required.)

 

Series operation

Yes (For up to two Power Supplies; external diodes required.)

Protective circuit operation indicator

No

Other

Ambient operating temperature

Refer to the derating curve in Engineering Data on Data Sheet (with no icing or

condensation).

Storage temperature

- 25 to 65 ° C (with no icing or condensation)

Ambient operating humidity

25% to 85% (Storage humidity: 25% to 90%)

Dielectric strength

3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)

2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)

1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)

Insulation resistance

100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC

Vibration resistance

10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions

Shock resistance

150 m/s2 , 3 times each in ± X, ± Y, ± Z directions

Output indicator

Yes (Color: Green)

EMI

Conducted

Conforms to EN 55011 Group 1 Class A and based on FCC Class A *9

Emissions

Radiated Emissions

Conforms to EN 55011 Group 1 Class A *9

EMS

Electrostatic

Conforms to EN61000-4-2

Discharge

Radiated

Conforms to EN61000-4-3

Electromagnetic

Field

Electrical Fast

Conforms to EN61000-4-4

Transient/Burst

Surge

Conforms to EN61000-4-5

Conducted

Conforms to EN61000-4-6

Disturbance

Voltage Dips/Short

Conforms to EN61000-4-11

Interruptions

Approved standards *9

UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)

cUL Listed: CSA C22.2 No.107.1

cUR: CSA C22.2 No. 60950-1

EN/VDE: EN50178 (= VDE 0160), Over voltage category III, EN 60950-1 (= VDE 0805

Teil 1) (Terminal block: Based on DIN 50274 (VDE 0660-514))

SEMI

---

SEMI F47-0200 (200-VAC input)

Weight *8

800 g max.

700 g max.

600 g max.

*1.When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not start. Refer to Overload Protection in Data Sheet.

*2.Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.

*3.Rated input voltage: 100 or 200 VAC at 100% load.

*4.Output characteristics: Specified at power supply output terminals.

*5.If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.

*6.For details, refer to Overload Protection in Data Sheet.

*7.To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON.

*8.The weight indicated is for Front-mounting, Open-frame Power Supply.

*9.The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC). 

 

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: