D4GS-N2T Travel Switch NEWD4GS-N2T OMRON Travel Switch NEWOMRON Travel Switch D4GS-N2T
Product Description:
Slim design with a width of only 17 mm (three-contact models).
Reversible design allowing either front or rear mounting.
Built-in Switches with two- or three-terminal contact construction are available.
Operation Key with rubber mounting hole to absorb vibration and shock.
IP67 degree of protection.
Specifications:
Degree of protection *1
IP67 (EN60947-5-1)
Durability *2
Mechanical
1,000,000 operations min.
Electrical
100,000 operations min. (1 A resistive load at 125 VAC) *3
Operating speed
0.1 to 0.5 m/s
Operating frequency
30 operations/minute max.
Direct opening force *4
60 N min.
Direct opening travel *4
10 mm min.
Contact resistance
300 mΩ max. (with 1 m cable)
Minimum applicable load *5
Resistive load of 4 mA at 24 VDC (N-level reference value)
Rated insulation voltage (Ui)
250 V
Rated frequency
50/60 Hz
Protection against electric shock
Class II (double insulation) (IEC60536)
Pollution degree (operating environment)
3 (EN60947-5-1)
Impulse withstand
Between terminals of same polarity
2.5 kV
voltage
Between terminals of different
4 kV
(EN60947-5-1)
polarity
Between each terminal and non-
6 kV
current carrying metallic parts
Insulation resistance
100 MΩ min. (at 500 VDC) between terminals of the same polarities,
between terminals of different polarities, and between each terminal
and non-current carrying metal parts
Contact gap
2 × 2 mm min.
Vibration resistance
Malfunction
10 to 55 Hz, 0.35 mm single amplitude
Shock resistance
Destruction
1,000 m/s2 min.
Malfunction
300 m/s2 min.
Conditional short-circuit current
100 A (EN60947-5-1)
Conventional free air thermal current (Ith)
2.5 A (EN60947-5-1)
Ambient operating temperature
-30 to 70°C (with no icing)
Ambient operating humidity
95% max.
Cable
UL2464 No. 22 AWG, finishing O.D.: 7.2 mm
Weight
Approx. 120 g (D4GS-N1R, with 1 m cable)
Note:
1.The above values are initial values.
2.The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced.
*1.The degree of protection shown above is based on the test method specified in EN60947-5-1. Be sure to confirm in advance the sealing performance under the actual operating environment and conditions.
Although the switch box is protected from dust, oil, or water penetration, do not use the D4GS-N in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2.The durability conditions are an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative.
*3.When the ambient temperature is 35°C or higher, do not apply 1 A at 125 VAC to more than one circuit.
*4.These figures are minimum requirements for safe operation.
*5.The value given for minimum applicable load is a reference value for microloads. The value will vary depending on factors such as the switching frequency, the ambient environment, and the reliability level. Be sure to confirm correct operation with the actual load before application.