No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
EE-SX910-R Photoelectric Switch NEWEE-SX910-R OMRON Photoelectric Switch NEWOMRON Photoelectric Switch EE-SX910-R
Product Description:
Type
Standard
L-shaped
F-shaped
R-shaped
U-shaped
NPN models
Pre-wired models
EE-SX910-R
EE-SX911-R
EE-SX912-R
EE-SX913-R
EE-SX914-R
PNP models
Pre-wired models
EE-SX910P-R
EE-SX911P-R
EE-SX912P-R
EE-SX913P-R
EE-SX914P-R
Sensing distance
5 mm (slot width)
Sensing object
Opaque: 1.2 × 0.8 mm min.
Differential distance
0.025 mm max. *1
Light source
GaAs infrared LED with a peak wavelength of 940 nm
Indicator
Light indicator (orange LED)
Supply voltage
5 to 24 VDC ±10%, ripple (p-p): 10% max.
Current consumption
21 mA max.
Control output
Load power supply voltage: 5 to 24 VDC
Load current: 50 mA max.
OFF current: 0.5 mA max.
50 mA load current with a residual voltage of 1.0 V max.
5 mA load current with a residual voltage of 0.4 V max.
Protection circuits
Power supply reverse polarity protection; output reverse polarity protection
(only OUT2 on models with NPN output)
Response frequency
1 kHz min. (3 kHz average) *2
Ambient illumination
1,000 lx max. with fluorescent light on the surface of the receiver
Ambient temperature range
Operating: -25 to 55°C
Storage: -30 to 80°C (with no icing or condensation)
Ambient humidity range
Operating: 5% to 85%
Storage: 5% to 95% (with no icing or condensation)
Vibration resistance (Destruction)
10 to 2,000 Hz (peak acceleration: 150m/s2)
0.75-mm single amplitude for 2.5 h (15-min periods, 10 cycles) each in X, Y, and Z directions
Shock resistance (Destruction)
500 m/s2 for 3 times each in X, Y, and Z directions
Degree of protection
IEC60529 IP50
Connecting method
Pre-wired Models (standard cable length: 1 m)
Weight
Pre-wired Models
Approx. 17 g
(packed state)
Materials
Case/cover
Polybutylene phthalate (PBT)
Emitter/receiver
Polycarbonate (PC)
*1The differential distance is the value when a sensing object is moved in a lateral direction to the slot.
*2.The response frequency was measured by detecting the following rotating disk.