No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
E2EV-X2C1 Proximity Switch NEWroduct Description:
Same sensing distance for non-ferrous metals, such as aluminum and brass, and ferrous metals.
Maximum sensing distance of 10 mm.
Specifications:
Model | E2EV-X2C1 | E2EV-X5C1 | E2EV-X10C1 | |
E2EV-X2C2 | E2EV-X5C2 | E2EV-X10C2 | ||
Sensing distance | 2mm ±10% | 5 mm ±10% | 10 mm ±10% | |
Set distance | 0 to 1.4 mm | 0 to 3.5 mm | 0 to 7 mm | |
Differential travel | 10% max. of sensing distance | |||
Detectable object | Ferrous metal and non-ferrous metal | |||
Standard sensing object | Aluminum: 12 × 12 × 1 mm | Aluminum: 18 × 18 × 1 mm | Aluminum: 30 × 30 × 1 mm | |
Response frequency * | 150 Hz | 70 Hz | ||
Power supply voltage | 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | |||
(operating voltage range) | ||||
Current consumption | 15 mA max. | |||
Control | Load | NPN open-collector output, 100 mA max. (at 30 VDC) | ||
output | current | |||
| Residual | 2 V max. (Load current: 100 mA, Cable length: 2 m) | ||
| voltage | |||
Indicators | Detection indicator (red) | |||
Operation mode | C1 Models: NO | |||
(with sensing object approaching) | C2 Models: NC | |||
| Refer to Datasheet. | |||
Protection circuits | Reverse polarity protection, Load short-circuit protection, Surge suppressor | |||
Ambient temperature range | Operating/Storage: -10 to 55°C (with no icing or condensation) | |||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
Temperature influence | ±20% max. of sensing distance at 23°C in the temperature range of -10 to 55°C | |||
Voltage influence | ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | |||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||
Weight (packed state) | Approx. 120 g | Approx. 140 g | Approx. 190 g | |
Materials | Case | Nickel-plated brass | ||
Sensing | Heat-resistant ABS | |||
surface | ||||
Clamping | Nickel-plated brass | |||
nuts | ||||
Toothed | Zinc-plated iron | |||
washer | ||||
Accessories | Instruction manual |
The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance for the DC switching section of half the sensing distance.
E2EV-X2C1 OMRON Proximity Switch NEWroduct Description:
Same sensing distance for non-ferrous metals, such as aluminum and brass, and ferrous metals.
Maximum sensing distance of 10 mm.
Specifications:
Model
E2EV-X2C1
E2EV-X5C1
E2EV-X10C1
E2EV-X2C2
E2EV-X5C2
E2EV-X10C2
Sensing distance
2mm ±10%
5 mm ±10%
10 mm ±10%
Set distance
0 to 1.4 mm
0 to 3.5 mm
0 to 7 mm
Differential travel
10% max. of sensing distance
Detectable object
Ferrous metal and non-ferrous metal
Standard sensing object
Aluminum: 12 × 12 × 1 mm
Aluminum: 18 × 18 × 1 mm
Aluminum: 30 × 30 × 1 mm
Response frequency *
150 Hz
70 Hz
Power supply voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
(operating voltage range)
Current consumption
15 mA max.
Control
Load
NPN open-collector output, 100 mA max. (at 30 VDC)
output
current
Residual
2 V max. (Load current: 100 mA, Cable length: 2 m)
voltage
Indicators
Detection indicator (red)
Operation mode
C1 Models: NO
(with sensing object approaching)
C2 Models: NC
Refer to Datasheet.
Protection circuits
Reverse polarity protection, Load short-circuit protection, Surge suppressor
Ambient temperature range
Operating/Storage: -10 to 55°C (with no icing or condensation)
Ambient humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±20% max. of sensing distance at 23°C in the temperature range of -10 to 55°C
Voltage influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67, in-house standards: oil-resistant
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 120 g
Approx. 140 g
Approx. 190 g
Materials
Case
Nickel-plated brass
Sensing
Heat-resistant ABS
surface
Clamping
Nickel-plated brass
nuts
Toothed
Zinc-plated iron
washer
Accessories
Instruction manual
The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance for the DC switching section of half the sensing distance.
No comment |