Your Position: Home > Transducer/Sensor > Photoelectric Sensors > Photoelectric Switch > FL7M-8J6AND Cylindrical Proximity Sensors NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

FL7M-8J6AND Cylindrical Proximity Sensors NEW

prevnext

FL7M-8J6AND Cylindrical Proximity Sensors NEW
  • Market price: $ 204.6
  • Shop price: $ 62.0
  • Goods click count: 306
  • Total:
  • Quantity:
Add to cart collect
  

Description

FL7M-8J6AND Omron Cylindrical Proximity Sensors NEW

Product Description:

Long sensing distance (2 times the sensing distance of a regular FL7M)

DC 2-wire no-polarity function reduces wiring costs

Stable sensing area is shown by the setting indicator

Firefly glow indicator lamp can be seen from any direction Sealed to IP67G.

Specifications:

Catalog listing

FL7M-4 6N (-CN03)

FL7M-8 6N (-CN03)

FL7M-14 6N (-CN03)

FL7M-20 6N (-CN03)

Actuation method

High-frequency oscillation (unshielded)

Rated sensing distance

4 ±0.4mm

8 ±0.8mm

14 ±1.4mm

20 ±2mm

Usable sensing distance

0 to 3.2mm

0 to 6.4mm

0 to 11.2mm

0 to 16mm

Standard target object

20 x 20 x 1mm iron

30 x 30 x 1mm iron

30 x 30 x 1mm iron

54 x 54 x 1mm iron

Differential travel

15% max. of sensing distance

10% max. of sensing distance

Rated supply voltage

12/24Vdc

Operating voltage range

10 to 30Vdc

Leakage current

0.8mA max.

Control output Switching current Voltage drop Output dielectric strength

3 to 100mA

3V max. (at 100mA switching current with 2m cable),

30Vdc

Operating frequency

1kHz

800Hz

400Hz

100Hz

Temperature drift (% of sensing distance, taking +25? as standard temp.)

±15% max., in the -25 to +70? range

±10% max., in the -25 to +70? range

±10% max., in the -10 to +60? range

Supply voltage drift

±1% max. of sensing distance, taking rated supply voltage as standard voltage

Indicator lamps

N.C. type: Operation indication: orenge light goes out in sensing area N.O. type: Operation indication: lights up (orenge or green) upon output Setting indication: lights up (green) in stable sensing area

Operating temperature

-25 to +70?

-10 to +60?

Insulation resistance

50MQmin. (by 500V megger)

Dielectric strength

1000Vac, 50/60Hz for 1 minute

Vibration resistance

10 to 55Hz, 1.5mm peak-to peak amplitude, 2 hrs each in X, Y and Z directions

Shock resistance

980m/s2 10 times each in X, Y and Z directions

Protective structure

IP67 (IEC standard), IP67G (JEM standard)

Weight Preleaded type (main unit + standard 2m cable) Preleaded connector type (main unit + 30cm cable)

Approx. 45g

Approx. 55g

Approx. 130g

Approx. 180g

Approx. 30g

Approx. 40g

Approx. 70g

Approx. 110g

Circuit protection

Surge absorption, load short-circuit protection, reverse connection protection circuit

Wiring method

preleaded (standard 2m cable), Preleaded connector (30cm cable)

Material Sensor Connector

Case

SUS

Ni-plated brass

Sensing face

PBT

Housing

-CN03: polyester elastomer

Holder

PBT

Contact

-CN03: gold-plated brass

 



  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: