No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
FL7M-8J6AND Cylindrical Proximity Sensors NEWFL7M-8J6AND Omron Cylindrical Proximity Sensors NEWProduct Description:
Long sensing distance (2 times the sensing distance of a regular FL7M)
DC 2-wire no-polarity function reduces wiring costs
Stable sensing area is shown by the setting indicator
Firefly glow indicator lamp can be seen from any direction Sealed to IP67G.
Specifications:
Catalog listing
FL7M-4 6N (-CN03)
FL7M-8 6N (-CN03)
FL7M-14 6N (-CN03)
FL7M-20 6N (-CN03)
Actuation method
High-frequency oscillation (unshielded)
Rated sensing distance
4 ±0.4mm
8 ±0.8mm
14 ±1.4mm
20 ±2mm
Usable sensing distance
0 to 3.2mm
0 to 6.4mm
0 to 11.2mm
0 to 16mm
Standard target object
20 x 20 x 1mm iron
30 x 30 x 1mm iron
30 x 30 x 1mm iron
54 x 54 x 1mm iron
Differential travel
15% max. of sensing distance
10% max. of sensing distance
Rated supply voltage
12/24Vdc
Operating voltage range
10 to 30Vdc
Leakage current
0.8mA max.
Control output Switching current Voltage drop Output dielectric strength
3 to 100mA
3V max. (at 100mA switching current with 2m cable),
30Vdc
Operating frequency
1kHz
800Hz
400Hz
100Hz
Temperature drift (% of sensing distance, taking +25? as standard temp.)
±15% max., in the -25 to +70? range
±10% max., in the -25 to +70? range
±10% max., in the -10 to +60? range
Supply voltage drift
±1% max. of sensing distance, taking rated supply voltage as standard voltage
Indicator lamps
N.C. type: Operation indication: orenge light goes out in sensing area N.O. type: Operation indication: lights up (orenge or green) upon output Setting indication: lights up (green) in stable sensing area
Operating temperature
-25 to +70?
-10 to +60?
Insulation resistance
50MQmin. (by 500V megger)
Dielectric strength
1000Vac, 50/60Hz for 1 minute
Vibration resistance
10 to 55Hz, 1.5mm peak-to peak amplitude, 2 hrs each in X, Y and Z directions
Shock resistance
980m/s2 10 times each in X, Y and Z directions
Protective structure
IP67 (IEC standard), IP67G (JEM standard)
Weight Preleaded type (main unit + standard 2m cable) Preleaded connector type (main unit + 30cm cable)
Approx. 45g
Approx. 55g
Approx. 130g
Approx. 180g
Approx. 30g
Approx. 40g
Approx. 70g
Approx. 110g
Circuit protection
Surge absorption, load short-circuit protection, reverse connection protection circuit
Wiring method
preleaded (standard 2m cable), Preleaded connector (30cm cable)
Material Sensor Connector
Case
SUS
Ni-plated brass
Sensing face
PBT
Housing
-CN03: polyester elastomer
Holder
PBT
Contact
-CN03: gold-plated brass
No comment |