No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
E3Z-LT61 Photoelectric Sensors NEWE3Z-LT61 Omron Photoelectric Sensors NEWProduct Description:
Laser Type , Through-Beam Type , Pre-Wired Type , Sensing Distance 60m , NPN Transistor Output.
Specifications:
Sensing method
Through-beam
Sensing distance
0 m to 60 m
Spot size
5mm dia. Max. (At sensing distance of 3m)
Standard sensing object
Opaque: 12 mm dia. Min.
Minimum sensing object
6 mm dia. Min. (at sensing distance 3m)
Directional angle
Receiver:3 to 15 DEG
Light source
Semiconductor laser diode(red) (655nm)
Classification of laser
IEC: CLASS 1
FDA: CLASS 2
JIS: CLASS 1Power supply voltage
12 to 24 VDC -10% to 10% (ripple(p-p) :10% Max.)
Current consumption
Emitter: 15mA DC Max., Receiver: 20mA DC Max.
Control output (Output type)
NPN open collector output
Control output (Load current)
0 to 100 mA
Control output (Residual voltage)
(DC) 1 V Max. (Load current: Less than 10mA)
(DC) 2 V Max. (Load current: 10 to 100 mA)Operation mode
Light-ON/Dark-ON selectable
Load power supply voltage
26.4 VDC Max.
Protective circuit
Surge suppressor
Output short-cut protection
Output reverse polarity protection
Power supply reverse polarity protectionResponse time
1 ms Max.
Sensitivity setting
Single-turn adjustment
Ambient illuminance
Incandescent lamp:3000 lux Max., Sunlight:10000 lux Max.
Ambient temperature
Operating: -10 to 55 CEL
Storage: -25 to 70 CEL
(with no icing or condensation)Ambient humidity
Operating: 35 to 85 %RH
Storage: 35 to 95 %RH
(with no condensation)Insulation resistance
20 M OHM Min. at 500 VDC between charged parts and the case
Dielectric strength
1000 VAC at 50/60 Hz for 1 minute between charged parts and the case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
500m/s2 for 3 times each in X, Y, and Z directions
Degree of protection
IEC60529: IP67
Applicable standard (EC Directive (Low Voltage Directive))
EN60947-5-2
Applicable standard (EC Directive (EMC Directive))
EMI: EN60947-5-2
Emission Enclosure: EN55011 Group 1 class A
EMS: EN60947-5-2
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Burst: IEC61000-4-4
CE marking: EquippedConnection method
Pre-wired models (Cable length: 0.5 m)
Indicator
Operation indicator(orange), Stability indicator(green), Power indicator(orange)
Weight (packed state)
approx. 55 g
Tightening torque
0.5 N.m Max. (with M3 screw)
Material (case)
PBT
Material (lens)
Denatured Polyarylate
Accessories
Instruction manual
No comment |