No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
E3JM-DS70M4-G Photoelectric Sensors NEWE3JM-DS70M4-G Omron Photoelectric Sensors NEWProduct Description:
Two Models Contribute to Overall Cost Reduction.
E3JM Terminal Block Models
• Easy to wire and adjust.
E3JK Pre-wired Models
• Slim body is economically priced and full of functions..
Specifications:
Sensing method
Through-beam model
Retro-reflective model (with MSR function)
Diffuse-reflective model
Item
Model
E3JM-10?4(T)
E3JM-R4?4(T)
E3JM-DS70?4(T)
Sensing distance
10 m
4 m (When using E39-R1)
White paper (200 × 200 mm): 700 mm
Standard sensing object
Opaque: 14.8-mm dia. min.
Opaque: 75-mm dia. min.
--
Differential travel
--
20% max. of sensing distance
Directional angle
Both Emitter and Receiver 3° to 20°
1° to 5°
--
Light source (wavelength)
Infrared LED (950 nm)
Red LED (660 nm)
Infrared LED (950 nm)
Power supply voltage
12 to 240 VDC±10%, ripple (p-p): 10% max. 24 to 240 VAC±10%, 50/60 Hz
Power consumption
DC
3W max. (Emitter 1.5 W max. Receiver 1.5 W max.)
2W max.
AC
3W max. (Emitter 1.5 W max. Receiver 1.5 W max.)
2W max.
Control output
Relay output (E3JM-??M4 (T) model): SPDT, 250 VAC, 3A (cosφ=1) max., 5 VDC, 10 mA min. DC SSR output (E3JM-??S4 (T) model): 48 VDC, 100 mA max. (residual voltage: 2 V max.) Light-ON/Dark-ON selectable
Life expectancy (relay output)
Mechanical
50,000,000 times min. (switching frequency: 18,000 times/h)
Electrical
100,000 times min. (switching frequency: 1,800 times/h)
Response time
Relay output
(E3JM-??M4 (T) models) Operate or reset: 30 ms max.
DC SSR output
(E3JM-??S4 (T) models) Operate or reset: 5 ms max.
Sensitivity adjustment
--
One-turn adjuster
Timer function *
ON-delay/OFF-delay/One-shot delay switch selectable Delay time: 0.1 to 5 s (adjustable), only for E3JM-???4T
Ambient illumination (Receiver side)
Incandescent lamp: 3,000 lx max.
Ambient temperature range
Operating: −25°C to 55°C, Storage: −30°C to 70°C (with no icing or condensation)
Ambient humidity range
Operating: 45% to 85% (with no condensation), Storage: 35% to 95% (with no condensation)
Insulation resistance
20 M? min. at 500 VDC
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min.
Vibration resistance
Destruction
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Malfunction
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction
500 m/s2 3 times each in X, Y, and Z directions
Malfunction
100 m/s2 3 times each in X, Y, and Z directions
Degree of protection
IEC 60529: IP66
Connection method
Terminal block
Weight (packed state)
Approx. 270 g
Approx. 160 g
Material
Case
ABS (Acrylonitril Butadiene Styrene)
Lens
Methacrylic resin
Cover
Polycarbonate
Mounting Bracket
Iron
Accessories
Mounting Bracket (with screw), Nuts, Terminal Protection Cover, One set of cable connection nuts (excluding -US Models), Instruction manual, Reflector (E39-R1: only for Retro-reflective Sensors)