DC 2-Wire Model , Unshielded , M18 , Sensing Distance 14mm , Operation Mode NO.
Specifications:
Cylinder type sensing head size | M18 |
Type | Unshielded |
Sensing method | Inductive type |
Sensing distance | 14 mm -10% to +10% |
Setting distance | 0 to 11.2 mm |
Differential distance | 10% Max. of sensing distance |
Sensing object | Ferrous metal (Sensitivity lowers with non-ferrous metals.) |
Standard sensing object | Iron 30*30*1mm |
Response frequency | DC: 0.4 kHz (average) |
Power supply voltage | 12 to 24 VDC (ripple(p-p) :10% Max.) |
Operating voltage range | 10 to 30 VDC |
Leakage current | 0.8 mA Max. |
Control output (Output type) | DC 2-wire models with polarity |
Control output (Switching capacity) | 3 to 100 mA |
Control output (Residual voltage) | (DC) 3 V Max. ?under load current with cable length of 2m? |
Indicator | Operation indicator(red), Operation setting indicator(green) |
Operation mode | NO |
Protective circuit | Surge suppressor |
Output short-cut protection | |
Standard or Different frequency | Standard |
Ambient temperature | Operating: -25 to 70 CEL |
Storage: -40 to 85 CEL | |
(with no icing or condensation) | |
Ambient humidity | Operating: 35 to 95 %RH |
Storage: 35 to 95 %RH | |
(with no condensation) | |
Temperature influence | +-10% Max. of sensing distance in temperature range of -25 to +70CEL |
(As the basis for sensing distance of 23CEL) | |
Voltage influence | +-1% Max. of sensing distance in rated voltage range +-15%. (As the basis for sensing distance at standard power voltage) |
Insulation resistance | 50 M OHM Min. at 500VDC between charged parts and the case |
Dielectric strength | 1000 VAC 50/60 Hz for 1 minute between charged parts and the case |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance | 1000m/s2 for 10 times each in X, Y, and Z directions |
Degree of protection | IEC60529: IP67 |
Company standard: Oil-proof | |
Applicable standard (EC Directive (Low Voltage Directive)) | EN60947-1 |
EN60947-5-2 | |
Applicable standard (EC Directive (EMC Directive)) | EMI: EN60947-5-2 |
Emission Enclosure: CISPR11 Group 1 class A | |
EMS: EN60947-5-2 | |
Immunity ESD: IEC61000-4-2 | |
Immunity RF-interference: IEC61000-4-3 | |
Immunity Conducted Disturbance: IEC61000-4-6 | |
Immunity Burst: IEC61000-4-4 | |
CE marking: Equipped | |
Applicable standard (CCC mark) | Not equipped |
Connection method | Pre-wired models (Cable length: 5 m) |
Weight (Packed state) | approx. 265 g |
Material (case) | Brass nickel plating |
Material (sensing surface) | PBT |
Material (clamping nuts) | Brass nickel plating |
Material (toothed washer) | Iron zinc plating |
Accessories | Instruction manual |
E2E-X14MD1-M1GJ Omron Cylindrical Proximity Sensor NEWProduct Description:
DC 2-Wire Model , Unshielded , M18 , Sensing Distance 14mm , Operation Mode NO.
Specifications:
Cylinder type sensing head size
M18
Type
Unshielded
Sensing method
Inductive type
Sensing distance
14 mm -10% to +10%
Setting distance
0 to 11.2 mm
Differential distance
10% Max. of sensing distance
Sensing object
Ferrous metal (Sensitivity lowers with non-ferrous metals.)
Standard sensing object
Iron 30*30*1mm
Response frequency
DC: 0.4 kHz (average)
Power supply voltage
12 to 24 VDC (ripple(p-p) :10% Max.)
Operating voltage range
10 to 30 VDC
Leakage current
0.8 mA Max.
Control output (Output type)
DC 2-wire models with polarity
Control output (Switching capacity)
3 to 100 mA
Control output (Residual voltage)
(DC) 3 V Max. ?under load current with cable length of 2m?
Indicator
Operation indicator(red), Operation setting indicator(green)
Operation mode
NO
Protective circuit
Surge suppressor
Output short-cut protection
Standard or Different frequency
Standard
Ambient temperature
Operating: -25 to 70 CEL
Storage: -40 to 85 CEL
(with no icing or condensation)
Ambient humidity
Operating: 35 to 95 %RH
Storage: 35 to 95 %RH
(with no condensation)
Temperature influence
+-10% Max. of sensing distance in temperature range of -25 to +70CEL
(As the basis for sensing distance of 23CEL)
Voltage influence
+-1% Max. of sensing distance in rated voltage range +-15%. (As the basis for sensing distance at standard power voltage)
Insulation resistance
50 M OHM Min. at 500VDC between charged parts and the case
Dielectric strength
1000 VAC 50/60 Hz for 1 minute between charged parts and the case
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
1000m/s2 for 10 times each in X, Y, and Z directions
Degree of protection
IEC60529: IP67
Company standard: Oil-proof
Applicable standard (EC Directive (Low Voltage Directive))
EN60947-1
EN60947-5-2
Applicable standard (EC Directive (EMC Directive))
EMI: EN60947-5-2
Emission Enclosure: CISPR11 Group 1 class A
EMS: EN60947-5-2
Immunity ESD: IEC61000-4-2
Immunity RF-interference: IEC61000-4-3
Immunity Conducted Disturbance: IEC61000-4-6
Immunity Burst: IEC61000-4-4
CE marking: Equipped
Applicable standard (CCC mark)
Not equipped
Connection method
Pre-wired models (Cable length: 5 m)
Weight (Packed state)
approx. 265 g
Material (case)
Brass nickel plating
Material (sensing surface)
PBT
Material (clamping nuts)
Brass nickel plating
Material (toothed washer)
Iron zinc plating
Accessories
Instruction manual