E2E-C1C2 Proximity Switch NEWProduct Description:
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent mutual interference.
Superior environment resistance with standard cable made of oilresistant PVC and sensing surface made of material that resists cutting oil.
Specifications:
Size | 3 dia. | 4 dia. | M5 | 5.4 dia. | |
Shielded | Shielded | ||||
Model | E2E-CR6C/B[] | E2E-CR8C/B[] | E2E-X1C/B[] | E2E-C1C/B[] | |
Sensing distance | 0.6 mm ±15% | 0.8 mm ±15% | 1 mm ±15% | ||
Set distance | 0 to 0.4 mm | 0 to 0.5 mm | 0 to 0.7 mm | ||
Differential travel | 15% max. of sensing distance | ||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Data Sheet.) | ||||
Standard sensing | Iron, 3 × 3 × 1 mm | Iron, 5 × 5 × 1 mm | |||
object | |||||
Response frequency * | 2 kHz | 3 kHz | |||
Power supply voltage | 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | ||||
(operating voltage | |||||
range) | |||||
Current consumption | 10 mA max. | 17 mA max. | |||
Control | Load | Open-collector output, | Open-collector output, 100 mA max. (30 VDC max.) | ||
output | current | 80 mA max. (30 VDC max.) | |||
| Residual | 1 V max. | 2 V max. (Load current: 100 mA, Cable length: 2 m) | ||
| voltage | (Load current: 80 mA, | |||
|
| Cable length: 2 m) | |||
Indicators | Operation indicator (red) | ||||
Operation mode | C1/B1 Models: NO | ||||
(with sensing object | C2 Models: NC | ||||
approaching) | Refer to Data Sheet. | ||||
Protection circuits | Reverse polarity protection, Surge suppressor | ||||
Ambient | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
temperature range | |||||
Ambient | Operating/Storage: 35% to 95% (with no condensation) | ||||
humidity range | |||||
Temperature | ±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
influence | |||||
Voltage influence | ±5% max. of sensing distance | ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
at rated voltage in the rated | |||||
voltage ±10% range | |||||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | IEC 60529 IP66 | IEC 60529 IP67, in-house standards: oil-resistant | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) | ||||
Weight (packed state) | Approx. 60 g | ||||
Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | ||
Sensing | Heat-resistant ABS | ||||
surface | |||||
Clamping | Nickel-plated brass (E2E-X1C/B[] only) | ||||
nuts | |||||
Toothed | Zinc-plated iron (E2E-X1C/B[] only) | ||||
washer | |||||
Accessories | Instruction manual |
*The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
E2E-C1C2 OMRON Proximity Switch NEWProduct Description:
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent mutual interference.
Superior environment resistance with standard cable made of oilresistant PVC and sensing surface made of material that resists cutting oil.
Specifications:
Size
3 dia.
4 dia.
M5
5.4 dia.
Shielded
Shielded
Model
E2E-CR6C/B[]
E2E-CR8C/B[]
E2E-X1C/B[]
E2E-C1C/B[]
Sensing distance
0.6 mm ±15%
0.8 mm ±15%
1 mm ±15%
Set distance
0 to 0.4 mm
0 to 0.5 mm
0 to 0.7 mm
Differential travel
15% max. of sensing distance
Detectable object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Data Sheet.)
Standard sensing
Iron, 3 × 3 × 1 mm
Iron, 5 × 5 × 1 mm
object
Response frequency *
2 kHz
3 kHz
Power supply voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
(operating voltage
range)
Current consumption
10 mA max.
17 mA max.
Control
Load
Open-collector output,
Open-collector output, 100 mA max. (30 VDC max.)
output
current
80 mA max. (30 VDC max.)
Residual
1 V max.
2 V max. (Load current: 100 mA, Cable length: 2 m)
voltage
(Load current: 80 mA,
Cable length: 2 m)
Indicators
Operation indicator (red)
Operation mode
C1/B1 Models: NO
(with sensing object
C2 Models: NC
approaching)
Refer to Data Sheet.
Protection circuits
Reverse polarity protection, Surge suppressor
Ambient
Operating/Storage: -25 to 70°C (with no icing or condensation)
temperature range
Ambient
Operating/Storage: 35% to 95% (with no condensation)
humidity range
Temperature
±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
influence
Voltage influence
±5% max. of sensing distance
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
at rated voltage in the rated
voltage ±10% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP66
IEC 60529 IP67, in-house standards: oil-resistant
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 60 g
Materials
Case
Stainless steel (SUS303)
Nickel-plated brass
Sensing
Heat-resistant ABS
surface
Clamping
Nickel-plated brass (E2E-X1C/B[] only)
nuts
Toothed
Zinc-plated iron (E2E-X1C/B[] only)
washer
Accessories
Instruction manual
*The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
No comment |