No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
E2C-X5AH E2C Cylindrical Proximity Sensor NEWProduct Description:
Cylindrical Inductive Sensors with Separate Amplifiers Provide Variable Detecting Capabilities.
· Separate amplifier allows sensor to fit in space-confined sites, providing easy access for monitoring and remote adjustments
· Detecting distance and differential travel can be adjusted to meet specific application requirements
· Adjustable differential travel to set switching trigger point available on some amplifiers
Specifications:
Part number | E2C-CR5B | E2C-CR8A | E2C-CR8B | E2C-X5A | E2C-C1A |
Sensor type | Inductive | ||||
Size | 2.0 mm dia. | 3.5 mm dia. | 3.8 mm dia. | M18 | 5.4 mm dia. |
Type | Shielded | ||||
Required amplifier | E2C-AK4A, E2C-AM4A, E2C-GE4B or E2C-GF4B | E2C-AK4A, E2C-AM4A, E2C-GE4A, E2C-GF4A, E2C-JC4AP or E2C-WH4AF | |||
Detectable object type | Metallic objects | ||||
Usable setting distance at ambient (with standard target) | 0 to 0.5 mm (0 to 0.02 in) | 0 to 0.8 mm (0 to 0.03 in) | 0 to 5 mm | 0 to 1.0 mm (0 to 0.04 in) | |
Usable setting distance at 0° to 40°C (with standard target) | 0 to 0.7 mm (0 to 0.028 in) | 0 to 1.2 mm (0 to 0.047 in) | 0 to 7 mm | 0 to 1.5 mm (0 to 0.059 in) | |
Standard target size (mild steel, L x W x H) | 5 x 5 x 1 mm (0.20 x 0.20 x 0.04 in) | 18 x 18 x 1 mm | 5 x 5 x 1 mm (0.20 x 0.20 x 0.04 in) | ||
Differential travel | See "Differential Travel" tables | ||||
Response frequency | 1 kHz | 350 Hz | 1 kHz | ||
Housing | 304 stainless steel | Nickel-plated brass | Nickel-plated brass | ||
Sensing face | ABS | ||||
Cable sheath | Polyethylene | ||||
Mounting | — | Optional mounting strap Y92E-F3R5, order separately | Two lock washers and M18 nuts ncluded. Bracket Y92E-B18 optional. | — | |
Prewired | Two-conductor cable, 3 m (9.8 ft) length | ||||
Weight with cable | 10 g (0.4 oz.) | 40 g (1.4 oz.) | 140 g (4.9 oz.) | 45 g (1.6 oz.) | |
UL | — | ||||
NEMA | 1,2 | 1, 3, 4, 6, 12, 13 | |||
IEC 144 | IP64 | IP67 | |||
UL | — | ||||
CSA | — | ||||
Ambient operating temperature | -25° to 70°C (-13° to 158°F) | ||||
Vibration | 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude, 2 hours each, X and Y directions | ||||
Shock | 50 G's, 3 times each, X and Y directions |
E2C-X5AH Omron E2C Cylindrical Proximity Sensor NEWProduct Description:
Cylindrical Inductive Sensors with Separate Amplifiers Provide Variable Detecting Capabilities.
· Separate amplifier allows sensor to fit in space-confined sites, providing easy access for monitoring and remote adjustments
· Detecting distance and differential travel can be adjusted to meet specific application requirements
· Adjustable differential travel to set switching trigger point available on some amplifiers
Specifications:
Part number
E2C-CR5B
E2C-CR8A
E2C-CR8B
E2C-X5A
E2C-C1A
Sensor type
Inductive
Size
2.0 mm dia.
3.5 mm dia.
3.8 mm dia.
M18
5.4 mm dia.
Type
Shielded
Required amplifier
E2C-AK4A, E2C-AM4A, E2C-GE4B or E2C-GF4B
E2C-AK4A, E2C-AM4A, E2C-GE4A, E2C-GF4A, E2C-JC4AP or E2C-WH4AF
Detectable object type
Metallic objects
Usable setting distance at ambient (with standard target)
0 to 0.5 mm (0 to 0.02 in)
0 to 0.8 mm (0 to 0.03 in)
0 to 5 mm
(0 to 0.20 in)0 to 1.0 mm (0 to 0.04 in)
Usable setting distance at 0° to 40°C (with standard target)
0 to 0.7 mm (0 to 0.028 in)
0 to 1.2 mm (0 to 0.047 in)
0 to 7 mm
(0 to 0.276 in)0 to 1.5 mm (0 to 0.059 in)
Standard target size (mild steel, L x W x H)
5 x 5 x 1 mm (0.20 x 0.20 x 0.04 in)
18 x 18 x 1 mm
(0.71 x 0.71
x 0.04 in)5 x 5 x 1 mm (0.20 x 0.20 x 0.04 in)
Differential travel
See "Differential Travel" tables
Response frequency
1 kHz
350 Hz
1 kHz
Housing
304 stainless steel
Nickel-plated brass
Nickel-plated brass
Sensing face
ABS
Cable sheath
Polyethylene
Mounting
—
Optional mounting strap Y92E-F3R5, order separately
Two lock washers and M18 nuts ncluded. Bracket Y92E-B18 optional.
—
Prewired
Two-conductor cable, 3 m (9.8 ft) length
Weight with cable
10 g (0.4 oz.)
40 g (1.4 oz.)
140 g (4.9 oz.)
45 g (1.6 oz.)
UL
—
NEMA
1,2
1, 3, 4, 6, 12, 13
IEC 144
IP64
IP67
UL
—
CSA
—
Ambient operating temperature
-25° to 70°C (-13° to 158°F)
Vibration
10 to 55 Hz, 1.5 mm (0.06 in) double amplitude, 2 hours each, X and Y directions
Shock
50 G's, 3 times each, X and Y directions
No comment |