No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
WE45-P260 SICK Standard photoelectric switch NEWProduct Description:
Robust metal housing
Red light
Adjustable sensitivity
Front lens heating, optional
Pre-failure signalling output
Specifications:
Scanning range, max. typical | 350 m |
SensitivityAdjustable | Adjustable |
Light source1), light type | LED, infrared light |
Light spot diameter | Approx. 4.5 m at 300 m |
Angle of dispersion | Approx. 0.9° |
Supply voltage VS | 10...60 V DC2) |
Ripple3) | < 5 VSS |
Current consumption4) |
|
sender without heating | ≤ 50 mA |
sender with heating | ≤ 250 mA |
receiver without heating | ≤ 50 mA |
receiver with heating | ≤ 250 mA |
Switching outputs | PNP, Q and Q |
NPN, Q and Q | |
Output current IA max. | 200 mA |
Response time5) | ≤ 500 μs |
Max. switching frequency6) | 1000/s |
Pre-failure signalling output | Alarm |
Max. output current IAlarm | 100 mA, open collector |
Insufficient light received | Flashes at approx. 5/s, switch to VS |
Test input ”TE”, sender OFF | PNP: Test input to O V |
Connection type | Terminal connection |
Circuit protection7) | A, B, C |
Enclosure rating | IP 67 |
Ambient temperature TA | Operation – 25 °C...+ 55 °C8) |
Storage – 40 °C...+ 70 °C | |
Weight | Approx. 800 g |
Housing material | Metal housing |
1) Average service life 100,000 h at TA = + 25 °C
2) Limit values
3) May not exceed or fall short of VS tolerances
4) Without load
5) Signal transit time with resistive load
6) With light/dark ratio 1:1
8) Up to 140 °C with cooling plates (see Accessories)
7) A = VS connections reverse-polarity protected
B = Output QN and QP short-circuit protected
C = Interference pulse suppression
WE45-P260 SICK Standard photoelectric switch NEWProduct Description:
Robust metal housing
Red light
Adjustable sensitivity
Front lens heating, optional
Pre-failure signalling output
Specifications:
Scanning range, max. typical
350 m
SensitivityAdjustable
Adjustable
Light source1), light type
LED, infrared light
Light spot diameter
Approx. 4.5 m at 300 m
Angle of dispersion
Approx. 0.9°
Supply voltage VS
10...60 V DC2)
Ripple3)
< 5 VSS
Current consumption4)
sender without heating
≤ 50 mA
sender with heating
≤ 250 mA
receiver without heating
≤ 50 mA
receiver with heating
≤ 250 mA
Switching outputs
PNP, Q and Q
NPN, Q and Q
Output current IA max.
200 mA
Response time5)
≤ 500 μs
Max. switching frequency6)
1000/s
Pre-failure signalling output
Alarm
Max. output current IAlarm
100 mA, open collector
Insufficient light received
Flashes at approx. 5/s, switch to VS
Test input ”TE”, sender OFF
PNP: Test input to O V
Connection type
Terminal connection
Circuit protection7)
A, B, C
Enclosure rating
IP 67
Ambient temperature TA
Operation – 25 °C...+ 55 °C8)
Storage – 40 °C...+ 70 °C
Weight
Approx. 800 g
Housing material
Metal housing
1) Average service life 100,000 h at TA = + 25 °C
2) Limit values
3) May not exceed or fall short of VS tolerances
4) Without load
5) Signal transit time with resistive load
6) With light/dark ratio 1:1
8) Up to 140 °C with cooling plates (see Accessories)
7) A = VS connections reverse-polarity protected
B = Output QN and QP short-circuit protected
C = Interference pulse suppression
No comment |