Your Position: Home > Transducer/Sensor > Photoelectric Sensors > Photoelectric Switch > WE24-2B240 SICK Standard photoelectric switch NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

WE24-2B240 SICK Standard photoelectric switch NEW

prevnext

WE24-2B240 SICK Standard photoelectric switch NEW
  • Market price: $ 1980.0
  • Shop price: $ 600.0
  • Goods click count: 289
  • Total:
  • Quantity:
Add to cart collect
  

Description

WE24-2B240 SICK Standard photoelectric switch NEW

Product Description:

Robust metal housing

Large operating reserve and visible red light

PG cable gland or plug rotatable by 90°

Front lens heating and selectable time delay, optional

Specifications:

Scanning range, max. typical

0...60 m

Sensitivity

Adjustable

Light source1), light type

LED, red light

Light spot diameter

700 mm at of 50 m

Angle of dispersion/reception

1°/2.5°

Supply voltage VS

10...30 V DC2)

Ripple3)

< 5 VSS

Current consumption4)

Sender without heating

≤ 50 mA

Sender with heating

≤ 70 mA

Receiver without heating

≤ 40 mA

Receiver with heating

≤ 60 mA

Switching outputs

PNP or NPN, Q or Q

Output current IA max.

100 mA

Response time5)

≤ 500 μs

Max. switching frequency6)

1000/s

Pre-failure signalling output

Alarm, PNP

Time delay

Adjustable, 0.5...10 sec

Test input ”TE”

Sender switched off

Sender OFF

PNP or NPN: test input to 0 V

Connection types

Plug

PG cable gland

VDE protection class7)

?

Circuit protection8)

A, B, C

Enclosure rating

IP 67

Ambient temperature TA

Operation – 40 °C...+ 60 °C

Storage – 40 °C...+ 75 °C

Weight

Approx. 330 g

Housing material

Zinc die-cast housing

 

 

1) Average service life 100,000 h at TA = + 25 °C

2) Limit values

3) May not exceed or fall short of VS tolerances

4) Same values for WS and WE, without load

5) Signal transit time with resistive load

6) With light/dark ratio 1:1

7) Reference voltage 50 V DC

8) A = VS connections reverse-polarity protected

B = Output Q and Q– short-circuit protected

C = Interference pulse suppression

 



  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: