No comment |
>
Transducer/Sensor >
Photoelectric Sensors >
Photoelectric Switch >
IM12-04NCP-ZW1 SICK Inductive Proximity sensor NEWProduct description:
Installed flush or flush in metal
NAMUR (EN50227)
High-frequency switching
Solid brass, nickel-plated shell with M12x1mm fine thread
Degree of protection IP67
Technical specifications?
Sensing range Sn | 2 mm |
4 mm | |
Electrical configuration | DC 4-wire |
Supply voltage Vs | DC 10 ... 30 V |
Ripple Upp | ≤ 10%1) |
Voltage drop Ud | ≤ 1.2V2) |
Power consumption | ≤ 30 mA3) |
Continuous current Ia | ≤ 100 mA |
Time delay before availability tv | ≤ 250 ms |
Hysteresis H, of sr | 2... 10% |
Repeatability R | ?5 % (Ub and Ta constant)4) |
Temperature drift, of sr | ± 10 % |
EMC | According to EN 60947-5-2 |
Switching output | PNP/NPN config. |
Output function | Configurable |
Installation | flush |
Non-flush | |
Connection type | Connector, M12, 4-pin |
Cable, PVC, 2 m | |
Enclosure rating | IP 675) |
Max. switching frequency | 1000 Hz |
Dimensions | M12 x 16) |
Short-circuit protection | √ |
Reverse polarity protection | √ |
Power-up pulse suppression | √ |
Shock/vibration stress | 30 g, 11 ms/10 ... 55 Hz, 1 mm |
Ambient temperature Ta | –25 °C ... +70 °C |
Housing material | Stainless steel, plastic |
Tightening torque | 10 Nm |
Notes:
1) of ub
2) at Ia max
3) without load
4) of sr
5) according to EN 60529
6) Thread diameter x pitch (mm)
IM12-04NCP-ZW1 SICK Inductive Proximity sensor NEWProduct description:
Installed flush or flush in metal
NAMUR (EN50227)
High-frequency switching
Solid brass, nickel-plated shell with M12x1mm fine thread
Degree of protection IP67
Technical specifications?
Sensing range Sn
2 mm
4 mm
Electrical configuration
DC 4-wire
Supply voltage Vs
DC 10 ... 30 V
Ripple Upp
≤ 10%1)
Voltage drop Ud
≤ 1.2V2)
Power consumption
≤ 30 mA3)
Continuous current Ia
≤ 100 mA
Time delay before availability tv
≤ 250 ms
Hysteresis H, of sr
2... 10%
Repeatability R
?5 % (Ub and Ta constant)4)
Temperature drift, of sr
± 10 %
EMC
According to EN 60947-5-2
Switching output
PNP/NPN config.
Output function
Configurable
Installation
flush
Non-flush
Connection type
Connector, M12, 4-pin
Cable, PVC, 2 m
Enclosure rating
IP 675)
Max. switching frequency
1000 Hz
Dimensions
M12 x 16)
Short-circuit protection
√
Reverse polarity protection
√
Power-up pulse suppression
√
Shock/vibration stress
30 g, 11 ms/10 ... 55 Hz, 1 mm
Ambient temperature Ta
–25 °C ... +70 °C
Housing material
Stainless steel, plastic
Tightening torque
10 Nm
Notes:
1) of ub
2) at Ia max
3) without load
4) of sr
5) according to EN 60529
6) Thread diameter x pitch (mm)