6ES7453-3AH00-0AE0 SIEMENS Positioning Module New6ES7453-3AH00-0AE0 SIEMENS Positioning Module NewSIEMENS CONTROL MODULE 6ES7453-3AH00-0AE0
Product Description:
SIMATIC S7-400, CONTROL MODULE FM 455 S, 16 CHANNELS, STEP AND PULSE 8/16 AI + 16 DI + 32 DO
Features:
Supply voltage
Load voltage L+
Rated value (DC)
24 V
permissible range, lower limit (DC)
20.4 V
permissible range, upper limit (DC)
28.8 V
Input current
from load voltage L+ (without load), max.
400 mA; typ. 330 mA
Power losses
Power loss, typ.
10.7 W
Power loss, max.
16.2 W
Digital inputs
Number/binary inputs
16
Input characteristic curve acc. to IEC 61131, Type 2
Yes
Input voltage
Rated value, DC
24 V
for signal "0"
-3 to +5 V
for signal "1"
13 to 30 V
Input current
for signal "1", typ.
7 mA
Cable length
Cable length, shielded, max.
1000 m
Cable length unshielded, max.
600 m
Digital outputs
Number/binary outputs
32
Functionality/short-circuit strength
Yes; Electronic
Limitation of inductive shutdown voltage to
L+ (-1.5 V)
Lamp load, max.
5 W
Controlling a digital input
Yes
Load resistance range
lower limit
240 Ω
upper limit
4 kΩ
Output voltage
for signal "1", min.
L+ (-2.5 V)
Output current
for signal "1" rated value
0.1 A
for signal "1" permissible range for 0 to 60 °C, min.
5 mA
for signal "1" permissible range for 0 to 60 °C, max.
150 mA
for signal "0" residual current, max.
0.5 mA
Parallel switching of 2 outputs
for logic links
Yes
Switching frequency
with resistive load, max.
100 Hz
with inductive load, max.
0.5 Hz
on lamp load, max.
100 Hz
Cable length
Cable length, shielded, max.
1000 m
Cable length unshielded, max.
600 m
Analog inputs
Number of analog inputs
16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection
permissible input voltage for voltage input (destruction limit), max.
20 V
permissible input current for current input (destruction limit), max.
40 mA
Input ranges
Voltage
Yes
Current
Yes
Thermocouple
Yes
Resistance thermometer
Yes
Input ranges (rated values), voltages
0 to +10 V
Yes
Input resistance (0 to 10 V)
100 kΩ
-1.75 to +11.75 V
Yes
Input resistance (-1.75 to +11.75 V)
100 kΩ
-80 mV to +80 mV
Yes
Input resistance (-80 mV to +80 mV)
10 MΩ
Input ranges (rated values), currents
0 to 20 mA
Yes
Input resistance (0 to 20 mA)
50 Ω
0 to 23.5 mA
Yes
Input resistance (0 to 23.5 mA)
50 Ω
-3.5 to +23.5 mA
Yes
Input resistance (-3.5 to +23.5 mA)
50 Ω
4 to 20 mA
Yes
Input resistance (4 to 20 mA)
50 Ω
Input ranges (rated values), thermoelements
Type B
Yes
Input resistance (Type B)
10 MΩ
Type J
Yes
Input resistance (type J)
10 MΩ
Type K
Yes
Input resistance (Type K)
10 MΩ
Type R
Yes
Input resistance (Type R)
10 MΩ
Type S
Yes
Input resistance (Type S)
10 MΩ
Input ranges (rated values), resistance thermometers
Pt 100
Yes
Input resistance (Pt 100)
10 MΩ
Thermocouple (TC)
for thermocouples
Type B, J, K, R, S
[nicht versorgt: TAK_ABT261_001_000]
internal temperature compensation
Yes; Parameterizable
external temperature compensation with Pt100
Yes; Parameterizable
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer
Pt100 (standard)
Characteristic linearization
Parameterizable
Yes
Cable length
Cable length, shielded, max.
200 m; 50 m at 80 mV and thermocouples
Analog value creation
Measurement principle
integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max.
14 bit; 12 or 14 bit, parameterizable
Conversion time (per channel)
16.67 ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for 50 and 60 Hz
Settling time
for resistive load
0.1 ms
for capacitive load
3.3 ms
for inductive load
0.5 ms
Encoder
Connection of signal encoders
for voltage measurement
Yes
for current measurement as 4-wire transducer
Yes
Connectable encoders
2-wire BEROS
Yes
permissible quiescent current (2-wire BEROS), max.
1.5 mA
Errors/accuracies
Linearity error (relative to input area)
+/- 0,05 %
Temperature error (relative to input area)
+/- 0,005 %/K
Operational limit in overall temperature range
Voltage, relative to input area
+/-0.6 to +/-1%
Current, relative to input area
+/-0.6 to +/-1%
Resistance-type thermometer, relative to input area
+/-0.6 to +/-1%
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area
+/-0.4 to +/-0.6 %
Current, relative to input area
+/-0.4 to +/-0.6 %
Resistance-type thermometer, relative to input area
+/-0.4 to +/-0.6 %
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency
Series mode interference (peak value of interference < rated value of input range), min.
40 dB
common mode voltage (USS < 2.5 V) , min.
70 dB
Interrupts/diagnostics/status information
Substitute values connectable
Yes; Parameterizable
Control technology
Number of closed-loop controllers
16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection
Galvanic isolation
Galvanic isolation controller
between the channels
No
between the channels and the backplane bus
Yes; Optocoupler
Permissible potential difference
between inputs and MANA (UCM)
2.5 V DC
between M internally and the inputs
75 VDC / 60 VAC
Isolation
Isolation checked with
500 V DC
Connection method
required front connector
2x 48-pin
Dimensions
Width
50 mm
Height
290 mm
Depth
210 mm
Weight
Weight, approx.
1400 g