6ES7453-3AH00-0AE0 SIEMENS Positioning Module NewSIEMENS CONTROL MODULE 6ES7453-3AH00-0AE0
Product Description:
SIMATIC S7-400, CONTROL MODULE FM 455 S, 16 CHANNELS, STEP AND PULSE 8/16 AI + 16 DI + 32 DO
Features:
Supply voltage | |
Load voltage L+ | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Input current | |
from load voltage L+ (without load), max. | 400 mA; typ. 330 mA |
Power losses | |
Power loss, typ. | 10.7 W |
Power loss, max. | 16.2 W |
Digital inputs | |
Number/binary inputs | 16 |
Input characteristic curve acc. to IEC 61131, Type 2 | Yes |
Input voltage | |
Rated value, DC | 24 V |
for signal "0" | -3 to +5 V |
for signal "1" | 13 to 30 V |
Input current | |
for signal "1", typ. | 7 mA |
Cable length | |
Cable length, shielded, max. | 1000 m |
Cable length unshielded, max. | 600 m |
Digital outputs | |
Number/binary outputs | 32 |
Functionality/short-circuit strength | Yes; Electronic |
Limitation of inductive shutdown voltage to | L+ (-1.5 V) |
Lamp load, max. | 5 W |
Controlling a digital input | Yes |
Load resistance range | |
lower limit | 240 Ω |
upper limit | 4 kΩ |
Output voltage | |
for signal "1", min. | L+ (-2.5 V) |
Output current | |
for signal "1" rated value | 0.1 A |
for signal "1" permissible range for 0 to 60 °C, min. | 5 mA |
for signal "1" permissible range for 0 to 60 °C, max. | 150 mA |
for signal "0" residual current, max. | 0.5 mA |
Parallel switching of 2 outputs | |
for logic links | Yes |
Switching frequency | |
with resistive load, max. | 100 Hz |
with inductive load, max. | 0.5 Hz |
on lamp load, max. | 100 Hz |
Cable length | |
Cable length, shielded, max. | 1000 m |
Cable length unshielded, max. | 600 m |
Analog inputs | |
Number of analog inputs | 16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection |
permissible input voltage for voltage input (destruction limit), max. | 20 V |
permissible input current for current input (destruction limit), max. | 40 mA |
Input ranges | |
Voltage | Yes |
Current | Yes |
Thermocouple | Yes |
Resistance thermometer | Yes |
Input ranges (rated values), voltages | |
0 to +10 V | Yes |
Input resistance (0 to 10 V) | 100 kΩ |
-1.75 to +11.75 V | Yes |
Input resistance (-1.75 to +11.75 V) | 100 kΩ |
-80 mV to +80 mV | Yes |
Input resistance (-80 mV to +80 mV) | 10 MΩ |
Input ranges (rated values), currents | |
0 to 20 mA | Yes |
Input resistance (0 to 20 mA) | 50 Ω |
0 to 23.5 mA | Yes |
Input resistance (0 to 23.5 mA) | 50 Ω |
-3.5 to +23.5 mA | Yes |
Input resistance (-3.5 to +23.5 mA) | 50 Ω |
4 to 20 mA | Yes |
Input resistance (4 to 20 mA) | 50 Ω |
Input ranges (rated values), thermoelements | |
Type B | Yes |
Input resistance (Type B) | 10 MΩ |
Type J | Yes |
Input resistance (type J) | 10 MΩ |
Type K | Yes |
Input resistance (Type K) | 10 MΩ |
Type R | Yes |
Input resistance (Type R) | 10 MΩ |
Type S | Yes |
Input resistance (Type S) | 10 MΩ |
Input ranges (rated values), resistance thermometers | |
Pt 100 | Yes |
Input resistance (Pt 100) | 10 MΩ |
Thermocouple (TC) | |
for thermocouples | Type B, J, K, R, S |
[nicht versorgt: TAK_ABT261_001_000] | |
internal temperature compensation | Yes; Parameterizable |
external temperature compensation with Pt100 | Yes; Parameterizable |
Resistance thermometer (RTD) | |
Characteristic linearization | |
for resistance thermometer | Pt100 (standard) |
Characteristic linearization | |
Parameterizable | Yes |
Cable length | |
Cable length, shielded, max. | 200 m; 50 m at 80 mV and thermocouples |
Analog value creation | |
Measurement principle | integrating |
Integrations and conversion time/ resolution per channel | |
Resolution with overrange (bit including sign), max. | 14 bit; 12 or 14 bit, parameterizable |
Conversion time (per channel) | 16.67 ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for 50 and 60 Hz |
Settling time | |
for resistive load | 0.1 ms |
for capacitive load | 3.3 ms |
for inductive load | 0.5 ms |
Encoder | |
Connection of signal encoders | |
for voltage measurement | Yes |
for current measurement as 4-wire transducer | Yes |
Connectable encoders | |
2-wire BEROS | Yes |
permissible quiescent current (2-wire BEROS), max. | 1.5 mA |
Errors/accuracies | |
Linearity error (relative to input area) | +/- 0,05 % |
Temperature error (relative to input area) | +/- 0,005 %/K |
Operational limit in overall temperature range | |
Voltage, relative to input area | +/-0.6 to +/-1% |
Current, relative to input area | +/-0.6 to +/-1% |
Resistance-type thermometer, relative to input area | +/-0.6 to +/-1% |
Basic error limit (operational limit at 25 °C) | |
Voltage, relative to input area | +/-0.4 to +/-0.6 % |
Current, relative to input area | +/-0.4 to +/-0.6 % |
Resistance-type thermometer, relative to input area | +/-0.4 to +/-0.6 % |
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency | |
Series mode interference (peak value of interference < rated value of input range), min. | 40 dB |
common mode voltage (USS < 2.5 V) , min. | 70 dB |
Interrupts/diagnostics/status information | |
Substitute values connectable | Yes; Parameterizable |
Control technology | |
Number of closed-loop controllers | 16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection |
Galvanic isolation | |
Galvanic isolation controller | |
between the channels | No |
between the channels and the backplane bus | Yes; Optocoupler |
Permissible potential difference | |
between inputs and MANA (UCM) | 2.5 V DC |
between M internally and the inputs | 75 VDC / 60 VAC |
Isolation | |
Isolation checked with | 500 V DC |
Connection method | |
required front connector | 2x 48-pin |
Dimensions | |
Width | 50 mm |
Height | 290 mm |
Depth | 210 mm |
Weight | |
Weight, approx. | 1400 g |
6ES7453-3AH00-0AE0 SIEMENS Positioning Module NewSIEMENS CONTROL MODULE 6ES7453-3AH00-0AE0
Product Description:
SIMATIC S7-400, CONTROL MODULE FM 455 S, 16 CHANNELS, STEP AND PULSE 8/16 AI + 16 DI + 32 DO
Features:
Supply voltage
Load voltage L+
Rated value (DC)
24 V
permissible range, lower limit (DC)
20.4 V
permissible range, upper limit (DC)
28.8 V
Input current
from load voltage L+ (without load), max.
400 mA; typ. 330 mA
Power losses
Power loss, typ.
10.7 W
Power loss, max.
16.2 W
Digital inputs
Number/binary inputs
16
Input characteristic curve acc. to IEC 61131, Type 2
Yes
Input voltage
Rated value, DC
24 V
for signal "0"
-3 to +5 V
for signal "1"
13 to 30 V
Input current
for signal "1", typ.
7 mA
Cable length
Cable length, shielded, max.
1000 m
Cable length unshielded, max.
600 m
Digital outputs
Number/binary outputs
32
Functionality/short-circuit strength
Yes; Electronic
Limitation of inductive shutdown voltage to
L+ (-1.5 V)
Lamp load, max.
5 W
Controlling a digital input
Yes
Load resistance range
lower limit
240 Ω
upper limit
4 kΩ
Output voltage
for signal "1", min.
L+ (-2.5 V)
Output current
for signal "1" rated value
0.1 A
for signal "1" permissible range for 0 to 60 °C, min.
5 mA
for signal "1" permissible range for 0 to 60 °C, max.
150 mA
for signal "0" residual current, max.
0.5 mA
Parallel switching of 2 outputs
for logic links
Yes
Switching frequency
with resistive load, max.
100 Hz
with inductive load, max.
0.5 Hz
on lamp load, max.
100 Hz
Cable length
Cable length, shielded, max.
1000 m
Cable length unshielded, max.
600 m
Analog inputs
Number of analog inputs
16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection
permissible input voltage for voltage input (destruction limit), max.
20 V
permissible input current for current input (destruction limit), max.
40 mA
Input ranges
Voltage
Yes
Current
Yes
Thermocouple
Yes
Resistance thermometer
Yes
Input ranges (rated values), voltages
0 to +10 V
Yes
Input resistance (0 to 10 V)
100 kΩ
-1.75 to +11.75 V
Yes
Input resistance (-1.75 to +11.75 V)
100 kΩ
-80 mV to +80 mV
Yes
Input resistance (-80 mV to +80 mV)
10 MΩ
Input ranges (rated values), currents
0 to 20 mA
Yes
Input resistance (0 to 20 mA)
50 Ω
0 to 23.5 mA
Yes
Input resistance (0 to 23.5 mA)
50 Ω
-3.5 to +23.5 mA
Yes
Input resistance (-3.5 to +23.5 mA)
50 Ω
4 to 20 mA
Yes
Input resistance (4 to 20 mA)
50 Ω
Input ranges (rated values), thermoelements
Type B
Yes
Input resistance (Type B)
10 MΩ
Type J
Yes
Input resistance (type J)
10 MΩ
Type K
Yes
Input resistance (Type K)
10 MΩ
Type R
Yes
Input resistance (Type R)
10 MΩ
Type S
Yes
Input resistance (Type S)
10 MΩ
Input ranges (rated values), resistance thermometers
Pt 100
Yes
Input resistance (Pt 100)
10 MΩ
Thermocouple (TC)
for thermocouples
Type B, J, K, R, S
[nicht versorgt: TAK_ABT261_001_000]
internal temperature compensation
Yes; Parameterizable
external temperature compensation with Pt100
Yes; Parameterizable
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometer
Pt100 (standard)
Characteristic linearization
Parameterizable
Yes
Cable length
Cable length, shielded, max.
200 m; 50 m at 80 mV and thermocouples
Analog value creation
Measurement principle
integrating
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max.
14 bit; 12 or 14 bit, parameterizable
Conversion time (per channel)
16.67 ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for 50 and 60 Hz
Settling time
for resistive load
0.1 ms
for capacitive load
3.3 ms
for inductive load
0.5 ms
Encoder
Connection of signal encoders
for voltage measurement
Yes
for current measurement as 4-wire transducer
Yes
Connectable encoders
2-wire BEROS
Yes
permissible quiescent current (2-wire BEROS), max.
1.5 mA
Errors/accuracies
Linearity error (relative to input area)
+/- 0,05 %
Temperature error (relative to input area)
+/- 0,005 %/K
Operational limit in overall temperature range
Voltage, relative to input area
+/-0.6 to +/-1%
Current, relative to input area
+/-0.6 to +/-1%
Resistance-type thermometer, relative to input area
+/-0.6 to +/-1%
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area
+/-0.4 to +/-0.6 %
Current, relative to input area
+/-0.4 to +/-0.6 %
Resistance-type thermometer, relative to input area
+/-0.4 to +/-0.6 %
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency
Series mode interference (peak value of interference < rated value of input range), min.
40 dB
common mode voltage (USS < 2.5 V) , min.
70 dB
Interrupts/diagnostics/status information
Substitute values connectable
Yes; Parameterizable
Control technology
Number of closed-loop controllers
16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire connection
Galvanic isolation
Galvanic isolation controller
between the channels
No
between the channels and the backplane bus
Yes; Optocoupler
Permissible potential difference
between inputs and MANA (UCM)
2.5 V DC
between M internally and the inputs
75 VDC / 60 VAC
Isolation
Isolation checked with
500 V DC
Connection method
required front connector
2x 48-pin
Dimensions
Width
50 mm
Height
290 mm
Depth
210 mm
Weight
Weight, approx.
1400 g