No comment |
>
Transducer/Sensor >
Other Sensors >
E2K-C25ME1 Adjustable Long-distance Sensor NEWProduct Description:
• Detects both metallic and nonmetallic objects (water, plastic, etc.).
• CE Marking for DC 3-Wire and AC/DC 2-Wire Models.
• Noise-resistant Models added to the lineup for application in a wide range of industrial environments.
Specifications:
Item | Model | E2K-C25ME1 | E2K-C25ME2 | E2K-C25MY1 | E2K-C25MY2 |
Sensing distance * | 25 mm | ||||
Sensing area | 3 to 25 mm | ||||
Detectable object | Conductors and dielectrics | ||||
Standard sensing object | Grounded metal plate: 50 × 50 × 1 mm | ||||
Differential travel | 15% max. of sensing sensing distance (when adjusted to 25 mm ±10% with standard sensing object) | ||||
Response frequency | 70 Hz | 10 Hz | |||
Power supply voltage (operating voltage range) | 12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max. | 100 to 220 VAC (90 to 250 VAC), 50/60 Hz | |||
Current consumption | E Models: 10 mA max. at 12 VDC, 16 mA max. at 24 VDC | ||||
Leakage current | Y Models: 1 mA max. at 100 VAC (50/60 Hz) with output turned OFF, 2 mA max. at 200 VAC (50/60 Hz) with output turned OFF | ||||
Control output | Load current | 200 mA max. | 5 to 200 mA (resistive load) | ||
Residual voltage | 2 V max. (Load current: 200 mA, Cable length: 2 m) | Refer to Engineering Data on page 4. | |||
Indicators | Detection indicator (red) | Operation indicator (red) | |||
Operation mode (with sensing object approaching) | E1/Y1 Models: NO E2/Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on page 5 for details. | ||||
Protection circuits | Reverse polarity protection, Surge suppressor | Surge suppressor | |||
Ambient temperature range | Operating/Storage: −25 to 70°C (with no icing or condensation) | ||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of −10 to 55°C ±25% max. of sensing distance at 23°C in the temperature range of −25 to 70°C | ||||
Voltage influence | ±2% max. of sensing distance at the rated voltage in rated voltage ±15% range | ±2% max. of sensing distance at the rated voltage in rated voltage +20%, −10% range at 100 VAC, ±20% range at 200 VAC | |||
Insulation resistance | 50 M? min. (at 500 VDC) between current-carrying parts and case | ||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | 1,500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
Shock resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions | ||||
Degree of protection | IEC 60529 IP66 | ||||
Connection method | Pre-wired Models (Standard cable length: 2 m) | ||||
Weight (packed state) | Approx. 200 g | ||||
Materials | Case | Heat-resistant ABS | |||
Sensing surface | |||||
Accessories | Mounting Bracket, Instruction manual |
E2K-C25ME1 Omron Adjustable Long-distance Sensor NEWProduct Description:
• Detects both metallic and nonmetallic objects (water, plastic, etc.).
• CE Marking for DC 3-Wire and AC/DC 2-Wire Models.
• Noise-resistant Models added to the lineup for application in a wide range of industrial environments.
Specifications:
Item
Model
E2K-C25ME1
E2K-C25ME2
E2K-C25MY1
E2K-C25MY2
Sensing distance *
25 mm
Sensing area
3 to 25 mm
Detectable object
Conductors and dielectrics
Standard sensing object
Grounded metal plate: 50 × 50 × 1 mm
Differential travel
15% max. of sensing sensing distance (when adjusted to 25 mm ±10% with standard sensing object)
Response frequency
70 Hz
10 Hz
Power supply voltage (operating voltage range)
12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max.
100 to 220 VAC (90 to 250 VAC), 50/60 Hz
Current consumption
E Models: 10 mA max. at 12 VDC, 16 mA max. at 24 VDC
Leakage current
Y Models: 1 mA max. at 100 VAC (50/60 Hz) with output turned OFF, 2 mA max. at 200 VAC (50/60 Hz) with output turned OFF
Control output
Load current
200 mA max.
5 to 200 mA (resistive load)
Residual voltage
2 V max. (Load current: 200 mA, Cable length: 2 m)
Refer to Engineering Data on page 4.
Indicators
Detection indicator (red)
Operation indicator (red)
Operation mode (with sensing object approaching)
E1/Y1 Models: NO E2/Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.
Protection circuits
Reverse polarity protection, Surge suppressor
Surge suppressor
Ambient temperature range
Operating/Storage: −25 to 70°C (with no icing or condensation)
Ambient humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±15% max. of sensing distance at 23°C in the temperature range of −10 to 55°C ±25% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
±2% max. of sensing distance at the rated voltage in rated voltage ±15% range
±2% max. of sensing distance at the rated voltage in rated voltage +20%, −10% range at 100 VAC, ±20% range at 200 VAC
Insulation resistance
50 M? min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
1,500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP66
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 200 g
Materials
Case
Heat-resistant ABS
Sensing surface
Accessories
Mounting Bracket, Instruction manual