E5CS-R1TU-W OMRON Thermostat NEW

OMRON Thermostat E5CS-R1TU-W  

Product Description:

Easy setting using DIP switch.

Models with two alarms added to Series, ideal for applications requiring alarms.

Universal-input (thermocouple/platinum resistance thermometer) models also available.

Clearly visible digital display with character height of 13.5 mm.

RoHS compliant.

Specifications:

Setting accuracy

Thermocouple *1: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.

Platinum resistance thermometer *2: (±0.5% of indication value or ±1°C, whichever is greater) ±1

digit max.

Indication accuracy

Thermistor *3: (1% FS of indication value) ±1 digit max.

(ambient temperature of 23°C)

 

Influence of temperature

R thermocouple inputs: (±2% of PV or ±10°C, whichever is greater) ±1 digit max.

Other thermocouple inputs: (±2% of PV or ±4°C, whichever is greater) ±1 digit max.

Platinum resistance thermometer inputs: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.

Influence of voltage

Thermistor: (±2% FS) ±1 digit max.

Hysteresis (for ON/OFF

0.2% FS (0.1% FS for universal-input (thermocouple/platinum resistance thermometer) models)

control)

Proportional band (P)

1 to 999°C (automatic adjustment using auto-tuning/self-tuning)

Integral time (I)

1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)

Derivative time (D)

1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)

Alarm output range

Absolute-value alarm: Same as the control range

Other: 0 to input setting range full scale (°C or °F)

Alarm hysteresis: 0.2°C or °F (fixed)

Control period

2/20 s

Sampling period

500 ms

Insulation resistance

20 MΩ min. (at 500 VDC)

Dielectric strength

2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity

Vibration

Malfunction

10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions

resistance

Destruction

10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions

Shock

Malfunction

100 m/s2 min., 3 times each in six directions

resistance

Destruction

300 m/s2 min., 3 times each in six directions

Life expectancy

Electrical

100,000 operations min. (relay output models)

Weight

Approx. 110 g (Controller only)

Degree of protection

Front panel: Equivalent to IP50, Enclosure Category 2 (IEC 60529), Rear case: IP20; Terminals: IP00

Memory protection

EEPROM (non-volatile memory) (number of writes: 1,000,000)

EMC

EMI Radiated: EN 55011 Group 1 Class A

EMI Conducted: EN 55011 Group 1 Class A

Radiated Electromagnetic Field Immunity: EN 61000-4-2: 4 kV contact discharge (level 2),

8 kV air discharge (level 3)

RF-interference Immunity: EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3),

10 V/m (900 MHz pulse modulated)

Conducted Disturbance Immunity: EN 61000-4-6: 3 V (0.15 to 80 MHz) (level 2)

Noise Immunity (First Transient Burst Noise): EN 61000-4-4

Burst Immunity: 2 kV power-line (level 3), 1 kV I/O signal-line (level 3)

Surge Immunity: EN 61000-4-5: Power line: Normal mode 1 kV; Common mode 2 kV,

Output line (relay output): Normal mode 1 kV; Common mode 2 kV

Voltage Dip/Interrupting Immunity: EN 61000-4-11 0.5 cycle, 100% (rated voltage)

Approved standards

UL 61010-1 (listing)

CSA C22.2 No.1010-1

Conformed standards

EN 61326, EN 61010-1, IEC 61010-1

*1.The following exceptions apply to thermocouples.

U, L: ±2°C ±1 digit max.

R: ±3°C ±1 digit max. at 200°C or less

*2.The following exception applies to platinum resistance thermometers.

Input set values 1 for E5CS-U: 1% FS ±1 digit max.

*3.The following exceptions apply to thermistors.

When the unit setting is °C, temperature indication ranges exceeding the set temperature range ±10% FS may not be accurate.

When the unit setting is °F, the temperature range for the input setting numbers 4 and 9 (609 to 630°F) and temperature indication ranges exceeding the set temperature range −5% FS to +10% FS may not be accurate.

 

  