No comment |
OMRON Thermostat E5CS-R1KJU-W
Product Description:
Easy setting using DIP switch.
Models with two alarms added to Series, ideal for applications requiring alarms.
Universal-input (thermocouple/platinum resistance thermometer) models also available.
Clearly visible digital display with character height of 13.5 mm.
RoHS compliant.
Specifications:
Setting accuracy | Thermocouple *1: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. | |
Platinum resistance thermometer *2: (±0.5% of indication value or ±1°C, whichever is greater) ±1 | ||
digit max. | ||
Indication accuracy | Thermistor *3: (1% FS of indication value) ±1 digit max. | |
(ambient temperature of 23°C) |
| |
Influence of temperature | R thermocouple inputs: (±2% of PV or ±10°C, whichever is greater) ±1 digit max. | |
Other thermocouple inputs: (±2% of PV or ±4°C, whichever is greater) ±1 digit max. | ||
Platinum resistance thermometer inputs: (±1% of PV or ±2°C, whichever is greater) ±1 digit max. | ||
Influence of voltage | Thermistor: (±2% FS) ±1 digit max. | |
Hysteresis (for ON/OFF | 0.2% FS (0.1% FS for universal-input (thermocouple/platinum resistance thermometer) models) | |
control) | ||
Proportional band (P) | 1 to 999°C (automatic adjustment using auto-tuning/self-tuning) | |
Integral time (I) | 1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning) | |
Derivative time (D) | 1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning) | |
Alarm output range | Absolute-value alarm: Same as the control range | |
Other: 0 to input setting range full scale (°C or °F) | ||
Alarm hysteresis: 0.2°C or °F (fixed) | ||
Control period | 2/20 s | |
Sampling period | 500 ms | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity | |
Vibration | Malfunction | 10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions |
resistance | Destruction | 10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions |
Shock | Malfunction | 100 m/s2 min., 3 times each in six directions |
resistance | Destruction | 300 m/s2 min., 3 times each in six directions |
Life expectancy | Electrical | 100,000 operations min. (relay output models) |
Weight | Approx. 110 g (Controller only) | |
Degree of protection | Front panel: Equivalent to IP50, Enclosure Category 2 (IEC 60529), Rear case: IP20; Terminals: IP00 | |
Memory protection | EEPROM (non-volatile memory) (number of writes: 1,000,000) | |
EMC | EMI Radiated: EN 55011 Group 1 Class A | |
EMI Conducted: EN 55011 Group 1 Class A | ||
Radiated Electromagnetic Field Immunity: EN 61000-4-2: 4 kV contact discharge (level 2), | ||
8 kV air discharge (level 3) | ||
RF-interference Immunity: EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3), | ||
10 V/m (900 MHz pulse modulated) | ||
Conducted Disturbance Immunity: EN 61000-4-6: 3 V (0.15 to 80 MHz) (level 2) | ||
Noise Immunity (First Transient Burst Noise): EN 61000-4-4 | ||
Burst Immunity: 2 kV power-line (level 3), 1 kV I/O signal-line (level 3) | ||
Surge Immunity: EN 61000-4-5: Power line: Normal mode 1 kV; Common mode 2 kV, | ||
Output line (relay output): Normal mode 1 kV; Common mode 2 kV | ||
Voltage Dip/Interrupting Immunity: EN 61000-4-11 0.5 cycle, 100% (rated voltage) | ||
Approved standards | UL 61010-1 (listing) | |
CSA C22.2 No.1010-1 | ||
Conformed standards | EN 61326, EN 61010-1, IEC 61010-1 |
*1.The following exceptions apply to thermocouples.
U, L: ±2°C ±1 digit max.
R: ±3°C ±1 digit max. at 200°C or less
*2.The following exception applies to platinum resistance thermometers.
Input set values 1 for E5CS-U: 1% FS ±1 digit max.
*3.The following exceptions apply to thermistors.
When the unit setting is °C, temperature indication ranges exceeding the set temperature range ±10% FS may not be accurate.
When the unit setting is °F, the temperature range for the input setting numbers 4 and 9 (609 to 630°F) and temperature indication ranges exceeding the set temperature range −5% FS to +10% FS may not be accurate.
E5CS-R1KJU-W OMRON Thermostat NEWOMRON Thermostat E5CS-R1KJU-W
Product Description:
Easy setting using DIP switch.
Models with two alarms added to Series, ideal for applications requiring alarms.
Universal-input (thermocouple/platinum resistance thermometer) models also available.
Clearly visible digital display with character height of 13.5 mm.
RoHS compliant.
Specifications:
Setting accuracy
Thermocouple *1: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.
Platinum resistance thermometer *2: (±0.5% of indication value or ±1°C, whichever is greater) ±1
digit max.
Indication accuracy
Thermistor *3: (1% FS of indication value) ±1 digit max.
(ambient temperature of 23°C)
Influence of temperature
R thermocouple inputs: (±2% of PV or ±10°C, whichever is greater) ±1 digit max.
Other thermocouple inputs: (±2% of PV or ±4°C, whichever is greater) ±1 digit max.
Platinum resistance thermometer inputs: (±1% of PV or ±2°C, whichever is greater) ±1 digit max.
Influence of voltage
Thermistor: (±2% FS) ±1 digit max.
Hysteresis (for ON/OFF
0.2% FS (0.1% FS for universal-input (thermocouple/platinum resistance thermometer) models)
control)
Proportional band (P)
1 to 999°C (automatic adjustment using auto-tuning/self-tuning)
Integral time (I)
1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)
Derivative time (D)
1 to 1,999 s (automatic adjustment using auto-tuning/self-tuning)
Alarm output range
Absolute-value alarm: Same as the control range
Other: 0 to input setting range full scale (°C or °F)
Alarm hysteresis: 0.2°C or °F (fixed)
Control period
2/20 s
Sampling period
500 ms
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals of different polarity
Vibration
Malfunction
10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
resistance
Destruction
10 to 55 Hz, 0.75-mm single amplitude for 2 hr each in X, Y, and Z directions
Shock
Malfunction
100 m/s2 min., 3 times each in six directions
resistance
Destruction
300 m/s2 min., 3 times each in six directions
Life expectancy
Electrical
100,000 operations min. (relay output models)
Weight
Approx. 110 g (Controller only)
Degree of protection
Front panel: Equivalent to IP50, Enclosure Category 2 (IEC 60529), Rear case: IP20; Terminals: IP00
Memory protection
EEPROM (non-volatile memory) (number of writes: 1,000,000)
EMC
EMI Radiated: EN 55011 Group 1 Class A
EMI Conducted: EN 55011 Group 1 Class A
Radiated Electromagnetic Field Immunity: EN 61000-4-2: 4 kV contact discharge (level 2),
8 kV air discharge (level 3)
RF-interference Immunity: EN 61000-4-3: 10 V/m (80-1000 MHz, 1.4-2.0 GHz amplitude modulated) (level 3),
10 V/m (900 MHz pulse modulated)
Conducted Disturbance Immunity: EN 61000-4-6: 3 V (0.15 to 80 MHz) (level 2)
Noise Immunity (First Transient Burst Noise): EN 61000-4-4
Burst Immunity: 2 kV power-line (level 3), 1 kV I/O signal-line (level 3)
Surge Immunity: EN 61000-4-5: Power line: Normal mode 1 kV; Common mode 2 kV,
Output line (relay output): Normal mode 1 kV; Common mode 2 kV
Voltage Dip/Interrupting Immunity: EN 61000-4-11 0.5 cycle, 100% (rated voltage)
Approved standards
UL 61010-1 (listing)
CSA C22.2 No.1010-1
Conformed standards
EN 61326, EN 61010-1, IEC 61010-1
*1.The following exceptions apply to thermocouples.
U, L: ±2°C ±1 digit max.
R: ±3°C ±1 digit max. at 200°C or less
*2.The following exception applies to platinum resistance thermometers.
Input set values 1 for E5CS-U: 1% FS ±1 digit max.
*3.The following exceptions apply to thermistors.
When the unit setting is °C, temperature indication ranges exceeding the set temperature range ±10% FS may not be accurate.
When the unit setting is °F, the temperature range for the input setting numbers 4 and 9 (609 to 630°F) and temperature indication ranges exceeding the set temperature range −5% FS to +10% FS may not be accurate.
No comment |