Product Description:
Main
Range of product
OsiSense XC
Series name
Standard format
Product or component type
Limit switch
Device short name
XCPR
Sensor design
Compact
Body type
Fixed
Head type
Rotary head
Material
Plastic
Body material
Plastic
Movement of operating head
Rotary
Type of operator
Thermoplastic spring return roller lever
Switch actuation
By 30° cam
Type of approach
2 directions lateral approach
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Cable entry
1 entry tapped for M20 x 1.5 cable gland, cable outer diameter: 7...13 mm
Number of poles
2
Contacts type and composition
1 NC + 1 NO
Contacts operation
Snap action
Maximum actuation speed
1.5 m/s
Complementary
Reset
With
Head material
Zamak
Fixing mode
By the body
Tracks
24/40 mm
Contacts insulation form
Zb
Positive opening
With
Positive opening minimum torque
0.25 N.m
Minimum torque for tripping
0.1 N.m
Contact code designation
A300, AC-15 240 V, Ie = 3 A), Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage
300 V conforming to CSA C22-2 No 14
300 V conforming to UL 508
500 V degree of pollution 3 conforming to EN 60947-1
500 V degree of pollution 3 conforming to IEC 60947-1
Resistance across terminals
<= 25 mOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Short circuit protection
10 A by gG cartridge fuse
Electrical durability
5000000 cycles, DC-13 , 120 V , 1 W, load factor: 0.5, operating rate: <= 60 cyc/mn
5000000 cycles, DC-13 , 24 V , 13 W, load factor: 0.5, operating rate: <= 60 cyc/mn
5000000 cycles, DC-13 , 48 V , 9 W, load factor: 0.5, operating rate: <= 60 cyc/mn
Width
31 mm
Height
65 mm
Depth
30 mm
Product weight
0.155 kg
CAD overall width
31 mm
CAD overall height
137 mm
CAD overall depth
43 mm
Terminals description ISO n°1
(13-14)NO
(21-22)NC
Environment
Shock resistance
50 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance
25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
IP degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IK degree of protection
IK04 conforming to EN 50102
Class of protection against electric shock
Class II conforming to IEC 61140
Class II conforming to NF C 20-030
Ambient air temperature for operation
-25...70 °C
Ambient air temperature for storage
-40...70 °C
Protective treatment
TC
Product certifications
CSA
UL
Standards
CSA C22-2 No 14
EN 60204-1
EN 60947-5-1
IEC 60204-1
IEC 60947-5-1
UL 508