SRF212 AZBIL Recorder NEWProduct Description:
Any combination of different inputs and recording scale can
be set freely.
DC voltage, thermocouple, resistance temperature detector
(RTD), communications, ON/OFF input
• Five recording formats are provided and can be freely selected:
Trend recording, trend + tabulation recording, trend +
schedule demand recording, fixed-time recording, fixeddate
recording
• Six measurement and calculation methods are provided
and can be selected to each channel:
Measurement value (PV value), deviation value between
channels, deviation value from fixed value, total calculation,
F value calculation, relative humidity calculation
• Free power supply allows use anywhere:
100 to 240V ac, 50/60 Hz
• Compact design. Only 187 mm deep
• Wide range of printing functions:
- Measurement value (PV value)
- Channel No.
- Tag (12 characters per channel)
- Engineering unit (6 characters per channel)
- Recording scale (2 types, upper/lower limit values)
- Chart feed speed
- Event status (details, time of occurrence/restoration)
- Time marker - Date
- Time (hours:minutes)
• Printing at the following start conditions is possible:
- Date - Time (hours:minutes)
- Recording format - Chart feed speed
- Recorder ID No.
• Manual demand printing also is possible.
Printing is started by DMD key or external switch input, time
(hours:minutes) and measurement values (PV values) are
printed.
• When trend + schedule demand recording is selected as
the recording format, the measurement value (PV value)
of up to eight preset times can automatically be printed.
• Up to 24 digital inputs are supported: 12 external switch
inputs coupled to remote switches, and 12 internal contact
inputs that are connected to internal signals.
Output signals for up to 96 events (4 types x 24 channels)
can be connected to any 12 internal contact inputs.
• Parameter setups can be assigned to user function keys.
(up to eight types for each of the two switches)
• Printing of "Date/Time (hours:minutes)", "Scale" and "event"
can be disabled.
• Seven list printing modes are available for printing setup
data: partial list print, function list print (four modes), total
list print and list print are available. Any list (85 characters
x 3 lines) can be printed as a user setup list from a loader
or by CPL communications.
• Upscale, downscale or OFF can be set as the thermocouple
burnout setting for each input channel.
• Batch count (1 to 99) that is incremented and printed out at
each start of recording can be set.
• Setup data is protected in EEPROM when the power is
OFF.
• Copy setting:
Various setup data can be copied between channels.
• Segment table setup:
Output values (Y-axis) for input values (X-axis) can be
offset by setting up segment tables.