No comment |
DME5000-324 SICK Distance detector NEWProduct Description:
Short positioning processes: very fast measuring time
High degree of system availability: highest accuracy and reproducibility
Convenient operation startup:illuminated LCD display with diagnosis information
Easy assembly and alignment concept: alignment bracket with spring/visible red light
Specifications:
Measurement range 1)
0.15 ... 300 m
Accuracy
±5 mm
Reproducibility 2)
4 mm
Light spot diameter
max. 550 mm at 300 m
Resolution (adjustable)
0.05 ... 5 mm
Light source 3), light type
Laser diode, red light
Laser category
2 (IEC 60825-1/C.D.R.H.)
Supply voltage VS
4)
Residual ripple 5)
5 VPP
Current consumption
< 250 mA at 24 V DC
with heating
< 1000 mA
Switching outputs MF1, MF2
B (push/pull)
Output (MF1/MF2)
HIGH: UV < 3 V; LOW < 2 V
Input (MF1) 6)
HIGH: > 12 V; LOW < 3 V
Output current IA max. 7)
100 mA (short-circuit/overload protected)
Connection type
Plug
VDE protection class 8)
?
Enclosure rating
IP 65
Ambient temperature
Operation –10 °C ... +55 °C
with heating
Operation –40 °C ... +55 °C
Storage –25 °C ... +75 °C
Weight
approx. 1650 g
Interfaces
SSI
Profibus 12 MBd
RS 422
DeviceNet 500 KBd
Effect of air pressure
0.3 ppm/hPa
Effect of air temperature
1 ppm/K
Temperature drift
typ. 0.1 mm/K
Measurement value output
2 ms
Initialisation period
800 ms
Max. running speed
5 m/s
EMC
EN 61000-6-2, EN 55011: class B
Mechanical load
Shock: EN 600 68-2-27/-2-29
Sine: EN 600 68-2-6
Noise: EN 600 68-2-64
1) On reflective tape “Diamond Grade”
2) Statistical error 1 σ, environmental conditions constant, minimal warm-up time: 10 min.
3) Average service life 50,000 h at TA = +25 °C
4) Limit values
5) May not exceed or fall short of VS tolerances
6) Not reverse-polarity protected
7) Max. 100 nF/20 mH
8) Reference voltage 32 V DC
No comment |