243-1EX01-0XE0 Siemens PLC 6GK7 New in box

Siemens PLC 6GK7 243-1EX01-0XE0
Product Description:
 The S7 brings to the user a powerful solution to a host of control applications, which is easy to adapt and expand the system. The S7 is a family of PLC’s which allows the user to tailor their selection of components which best suits their requirements, and is the long term successor to the highly successful S5 range. Whatever the S5 can do, the S7 can do more quickly and more easily.,The 3rd generation of S7-200 now builds on the success of the original range and exploits new CPU’s in order to produce even faster and more powerful range of PLC's. The range of CPU's available has been increased with the introduction of the new 224XP, as has the range of digital, analogue and communications expansion modules.,For the faster type of application real time control is easily achieved by use of the comprehensive range of built-in interrupts. Timed, Communication, High Speed Counter, High Speed Pulse Output, and hardware interrupts are all available, and the implementation of a priority table means that all the interrupts can work simultaneously.,Communications with S7-200 is built in. Inter PLC communications is achieved using two wire network which can be up to 1200 meters and can have up to 126 nodes. In "Freeport" mode the PLC's RS-485 port runs in free ASC11 mode making it possible to communicate with other devices.,In line with Siemens objective to make the programming of S7-200 as user friendly as possible MicroWin programming software has been further improved. These improvements all help minimise program development time. This has been achieved by including more and improving existing "wizards". These help program developers with the more routine/complex parts of their programs, e.g. TD200 configuration, PID loop configuration, High Speed Counter configuration, etc. Inclusion of context sensitive help also means that all the information required is at the users fingertips.
New CPU hardware support provides the option to turn off run mode edit to obtain more program memoryCPU 224XP supports onboard analogue I/O and two communication portsCPU 226 includes additional input filters and pulse catch facility0.22μs processing time per instruction
Modular Expansion up to 256 total I/O (except S7-221)Powerful Instruction Set, and Real Time performanceProgramming via RS-485 comms portAll models have EEPROM memories for user program storage2 or 4 x 30kHz pulse train outputs (dc powered models only )
Specifications:
(CP 243--1) Ethernet Module Order Number:
Order Number Expansion Module EM Inputs EM Outputs Removable Connector
6GK7 243--1EX00--OXE0 (CP 243--1) Ethernet Module -- 8 No
Eight Q outputs are used as logical controls of Ethernet function and do not directly control any external signals.
(CP 243--1) Ethernet Module General Specifications:
Order Number Module Name and Description Dimensions (mm) (W x H x D) Weight VDC Requirement+5 VDC +24 VDC
6GK7 243--1EX00--OXE0 (CP 243--1) Ethernet Module 71.2 x 80 x 62 approx.150 g 1.75 W   55 mA 60 mA
(CP 243--1) Ethernet Module Specifications:
General 6GK7 243- -1EX00--0XE0
Transmission Rate 10 Mbits/s and 100 Mbits/s
Flash memory size 1Mbyte
SDRAM memory size 8Mbyte
Interface ?
Connection to Industrial Ethernet (10/100 Mbit/s) 8-pin RJ45 socket
Input voltage 20.4 to 28.8 VDC
Maximum connections Maximum of 8 S7 connections (XPUT/XGET and READ/WRITE) plus 1 connection to STEP 7--Micro/WIN per (CP 243--1) Ethernet Module2
 
Starting time or restart time after a reset Approx. 10 seconds
User data quantities As client: up to 212 bytes for XPUT/XGETAs server: up to 222 bytes for XGET or READup to 212 bytes for XPUT or WRITE
Notes:
 The (CP 243--1) Ethernet module is a communications processor used for connecting the S7-200 system to Industrial Ethernet (IE). The S7-200 can be remotely configured, programmed and diagnosed via Ethernet using STEP 7 Micro/WIN. The S7-200 can communicate with another S7--200, S7-300, or S7-400 controller via Ethernet. It can also communicate with an OPC server.
 Industrial Ethernet is designed for industry. It can be used with either noise-free industrial twisted pair (ITP) technology, or the Industry-standard twisted pair (TP) technology. Industrial Ethernet can be implemented to offer a wide range of application specific uses, such as switching, high-speed redundancy, fast connects, and redundant networks. Using the (CP 243--1) Ethernet module, the S7-200 PLC is made compatible with a wide range of existing products that support Ethernet.

 

 


  

User Comment