H3DK-M1 AC?DC24-240 OMRON Time Relay NEW

OMRON Time Relay H3DK-M1 AC?DC24-240              

Product Description:

Multiple time ranges and operating modes let you cover a wide range of applications.

The time-limit DPDT output contacts can be changed to time-limit SPDT and instantaneous SPDT output contacts using a switch.

Sequence checks are easily performed by setting an instantaneous output to 0.

Start signal control for the H3DK-M.

Specifications:

Ratings

Power supply voltage *1

24 to 240 VAC/DC, 50/60 Hz *2

12 VDC *2

Allowable voltage fluctuation

24 to 240 VAC/DC: 85% to 110% of rated voltage

range

12 VDC: 90% to 110% of rated voltage

Power reset

Minimum power-OFF time: 0.1 s

Reset voltage

10% of rated voltage

Voltage input

24 to 240 VAC/DC

High level: 20.4 to 264 VAC/DC, Low level: 0 to 2.4 VAC/DC

12 VDC

High level: 10.8 to 13.2 VDC, Low level: 0 to 1.2 VDC

Power

H3DK-M2/-S2

At 240 VAC: 6.6 VA max. *4

consumption

H3DK-M1/-S1

At 240 VAC: 4.5 VA max. *4

*3

H3DK-M2A/-S2A

At 12 VDC: 0.9 W max.

 

H3DK-M1A/-S1A

At 12 VDC: 0.6 W max.

Control output

Contact output, 5 A at 250 VAC with resistive load (cosΦ = 1), 5 A at 30 VDC with resistive load *4, *5

Ambient operating temperature

-20 to 55°C (with no icing)

Storage temperature

-40 to 70°C (with no icing)

Ambient operating humidity

25% to 85%

*1.When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 A. Allow for this inrush current when turning ON and OFF the power supply to the Timer with device with a solid-state output, such as a sensor.

*2.DC ripple: 20% max.

*3.The power consumption is for mode A after the Timer times out.

For the H3DK-M[], the maximum power consumption is given, including the current consumed by the input circuit.

*4.Refer to DC Power Consumptions (Reference Information) on Data Sheet for DC power consumptions.

*5.The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer to Installation Pitch and Output Switching Capacity (Reference Values) in the below.

*6.125 VDC: 0.15 A max. with resistive load, 125 VDC: 0.1 A with L/R of 7 ms.

Minimum load: 10 mA at 5 VDC (P level, reference value)

Characteristics

Accuracy of operating time

±1% of FS max. (±1% ±10 ms max. at 1.2-s range) *

Setting error

±10% of FS ±0.05 s max. *

Minimum input signal width

50 ms* (start input)

Influence of voltage

±0.5% of FS max. (±0.5% ±10 ms max. at 1.2-s range)

Influence of temperature

±2% of FS max. (±2% ±10 ms max. at 1.2-s range)

Insulation resistance

100 MΩ min. at 500 VDC

Dielectric strength

Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC

50/60 Hz for 1 min.

Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz for 1 min.

Between contacts not located next to each other: 1,000 VAC 50/60 Hz for 1 min.

Impulse withstand voltage

24 to 240 VAC/VDC: 3 kV between power terminals, 4.5 kV between current-carrying metal parts and

exposed non-current-carrying metal parts

12 VDC: 1 kV between power terminals, 1.5 kV between current-carrying metal parts and exposed non-

current-carrying metal parts

Noise immunity

Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise): ±1.5 kV

Static immunity

Malfunction: 4 kV, Destruction: 8 kV

Vibration

Destruction

0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions

resistance

Malfunction

0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions

Shock

Destruction

1,000 m/s2 3 times each in 6 directions

resistance

Malfunction

100 m/s2 3 times each in 6 directions

Life

Mechanical

10 million operations min. (under no load at 1,800 operations/h)

expectancy

Electrical

100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)

Degree of protection

IP30 (Terminal block: IP20)

Weight

Approx. 120 g

 

 

  