H3AM-NS-B AC100-240V OMRON Timer NEW

OMRON Timer H3AM-NS-B AC100-240V

Product Description:

Incorporating an easy-to-see large setting dial with moving pointers.

Wide time-setting range of 0.2 s to 60 h (available through three time-range model types)

Wide AC power supply range (100 to 240 VAC)

IP65 watertight and dust-tight front panel.

Approved by UL and CSA.

Conforms to EN61812-1 and IEC60664-14 kV for Low Voltage, and EMC Directives.

Conforms to EMC standards.

Six-language instruction manual provided.

Programmable contact enables the building of a self-holding relay circuit as well as built-in instantaneous contact. (-NS)

Memory retention (-NSR)

Finger protection terminal block

Enables easy sequence checks through instantaneous outputs for a zero set value at any time range.

Specifications:

General

Operating mode

ON-delay

Screw tightening torque

0.98 Nm (10 kgf) max.

Input type

Voltage input

Output type

Relay: DPDT

Mounting method

Flush/Panel mounting, no restriction on mounting angle.

Approved standards

UL 508, CSA C22.2 No. 14

Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100

Output category according to IEC60947-5-1

 

Time Ranges

Model

Full scale on

dial

Set time unit

s

10 s

min

10 min

h (hour)

10 h (hour)

H3AM-[][][]-A

3

---

0.5 to 30 s

0.05 to 3 min

0.5 to 30 min

0.05 to 3 h

0.5 to 30 h

H3AM-[][][]-B

6

---

1 to 60 s

0.1 to 6 min

1 to 60 min

0.1 to 6 h

1 to 60 h

H3AM-[][][]-C

12

0.2 to12 s

2 to 120 s

0.2 to 12 min

2 to 120 min

0.2 to 12 h

---

Note: Instantaneous output is obtained by turning the time setting knob below "0" until the time setting knob stops.

Ratings

Rated supply voltage

100 to 240 VAC (50/60 Hz)

Operating voltage range

85% to 110% of rated supply voltage

Power reset (-NS)

Minimum power-opening time: 0.5 s

Reset input time (-NSR)

Minimum input time: 0.5 s

Reset voltage range (-NSR)

H level: 85 to 264 VAC

L level: 0 to 10 VAC

Power consumption

Approx. 9 VA (Approx. 5 W)

Control output

Contact output: 5 A at 250 VAC, resistive load (cosΦ = 1)

Ambient temperature

Operating: -10°C to 55°C (with no icing)

Storage: -25°C to 65°C (with no icing)

Ambient humidity

Operating: 35% to 85%

Note:

The minimum applicable load:

H3AM-NS: 10 mA at 5 VDC (failure level: P, reference value)

H3AM-NSR: 100 mA at 5 VDC (failure level: P, reference value)

Characteristics

Accuracy of operating time

±0.7% FS max.

Setting error

±2% FS max.

Reset time

Power reset: 0.5 s max.

Reset input time: 0.5 s max.

Influence of voltage

±1% FS max.

Influence of temperature

±2% FS max.

Insulation resistance

100 MΩ max. (at 500 VDC)

Dielectric strength

2,000 VAC (50/60 Hz) for 1 min between exposed non-current-carrying metal parts and current-carrying metal parts

2,000 VAC (50/60 Hz) for 1 min between the operating circuit and control output terminals

1,000 VAC (50/60 Hz) for 1 min between the operating power supply circuit and reset input circuit (H3AM-NSR only)

1,000 VAC (50/60 Hz) for 1 min between contacts not located next to each other

2,000 VAC (50/60 Hz) for 1 min between contacts of opposite poles

Impulse withstand voltage

3 kV between power terminals

4.5 kV between exposed non-current-carrying metal parts and current-carrying metal parts

Noise immunity

±1.5 kV (between power terminals) square-wave noise by a noise simulator

(pulse width: 100 ns/1 μs, 1-ns rise)

Static immunity

Malfunction: 8 kV

Destruction: 15 kV

Vibration resistance

Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)

Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 2 cycles each in 3 directions (8 min per cycle)

Shock resistance

Destruction: 300 m/s2 3 times each in 6 directions

Malfunction: 150 m/s2 (100 m/s2 in the front/back direction) 3 times each in 6 directions

Life expectancy

Mechanical: 5,000,000 times min. (under no load at 1,800 times/h)

Electrical: 100,000 times min. (5-A at 250 VAC, resistive load at 1,800 times/h)

Motor life expectancy

20,000 h

EMC

(EMI): EN61812-1

Emission Enclosure: EN55011 class A

Emission AC Mains: EN55011 class A

(EMS): EN61812-1

Immunity ESD: IEC61000-4-2: 6 kV contact discharge

8 kV air discharge

Immunity RF-interference: IEC61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)

10 V/m (Pulse-modulated, 900 MHz±5 MHz)

Immunity Power Frequency Magnetic Fields: IEC61000-4-8: 30 A/m (50 Hz)

Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0.15 to 80 MHz)

Immunity Burst: IEC61000-4-4: 2 kV power-line

2 kV I/O signal-line

Immunity Surge: IEC61000-4-5: 1 kV line to line

2 kV line to ground

Enclosure rating

IP65 (front panel only) (See note.) IP20 (terminal section)

Weight

Approx. 350 g

Note: A separately sold waterproof packing (Y92S-35) is necessary to ensure IP65 waterproofing between the Timer and installation panel.