No comment |
Product Description?
Ratings | |
Product classification | Bistable relays |
Coil ratings | Operate 24 VDC 52 mA |
Coil resistance | Operate: 470 Ohm |
Operate voltage (Set voltage) | 80% Max. |
Release voltage (Reset voltage) | 80% Max. |
Max. voltage | 110% (of rated voltage) |
Power consumption (Latching (Operate)) | 1.3 W |
Power consumption (Latching (Release)) | 0.6 W |
Operating indicator | Not equipped |
Coil surge killer | Not equipped |
Contact Type | DPDT |
Contact method | Single |
Contact material | Contact body material: Ag |
Contact rated load | 220 VAC 3 A (Resistive load (cos phi = 1)) |
Maximum switching voltage | 250 VAC (Resistive load (cos phi = 1)) |
Maximum switching current | AC: 3 A (Resistive load (cos phi = 1)) |
Maximum switching power | AC: 660 VA (Resistive load (cos phi = 1)) |
Failure rate | 1 mA at 1 VDC (failure level: P Reference value) |
Ambient temperature | Operating: -55 to 60 CEL |
Ambient humidity | Operating: 5 to 85% RH |
Characteristics | |
Contact resistance | Max. 50 mOhm, Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A |
Operating time (set time) | 15 ms Max. |
Release time (Reset time) | 15 ms Max. |
Min.set-reset signal width | 30 ms Min. |
Max.operating frequency (Mechanical) | 18000 opn./h |
Max.operating frequency (Erectrical) | 1800 opn./h |
Insulation resistance | Between coil and contacts: 100 MOhm Min. (at 500 VDC) |
Dielectric strength | Between coil and contacts: 1500 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min) |
Vibration resistance (Destruction) | 10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) for 2 hours each in X, Y, and Z directions (No defect in appearance and construction after applying variable vibration in each directions for 2 hours.) |
Vibration resistance (Malfunction) | 10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) in each direction |
Shock resistance (Destruction) | 1000 m/s**2 each direction 3 times (No defect in appearance and construction after applying shock in each directions 3 times.) |
Shock resistance (Malfunction) | 200 m/s**2 (Contacts must not open for 1 ms or longer after the relay is subjected to a shock in each direction 3 times.) |
Endurance (Mechanical) | 100000000 operations Min. |
Endurance (Electrical) | 200000 operations Min. |
Protective structure | Closed type (cover) |
Applicable standard (UL) | Standard No.: UL508 |
Applicable standard (CSA) | Standard No.: C22.2 No.0, No.14 |
Terminal structure | PCB |
Weight | Approx. 30 g |
MY2K DC24V OMRON RELAY New
Product Description?
Ratings
Product classification
Bistable relays
Standard typeCoil ratings
Operate 24 VDC 52 mA
Release 24 VDC 25 mACoil resistance
Operate: 470 Ohm
Release: 940 OhmOperate voltage (Set voltage)
80% Max.
Release voltage (Reset voltage)
80% Max.
Max. voltage
110% (of rated voltage)
Power consumption (Latching (Operate))
1.3 W
Power consumption (Latching (Release))
0.6 W
Operating indicator
Not equipped
Coil surge killer
Not equipped
Contact Type
DPDT
Contact method
Single
Contact material
Contact body material: Ag
Contact finish: Au platedContact rated load
220 VAC 3 A (Resistive load (cos phi = 1))
220 VAC 0.8 A (Inductive load (cos phi = 0.4))
24 VDC 3 A (Resistive load)
24 VDC 1.5 A (Inductive load (L/R = 7 ms))Maximum switching voltage
250 VAC (Resistive load (cos phi = 1))
250 VAC (Inductive load (cos phi = 0.4))
125 VDC (Resistive load)
125 VDC (Inductive load (L/R = 7 ms))Maximum switching current
AC: 3 A (Resistive load (cos phi = 1))
AC: 3 A (Inductive load (cos phi = 0.4))
DC: 3 A (Resistive load)
DC: 3 A (Inductive load (L/R = 7 ms))Maximum switching power
AC: 660 VA (Resistive load (cos phi = 1))
AC: 176 VA (Inductive load (cos phi = 0.4))Failure rate
1 mA at 1 VDC (failure level: P Reference value)
Ambient temperature
Operating: -55 to 60 CEL
Storage: -55 to 60 CEL
(with no icing or condensation)Ambient humidity
Operating: 5 to 85% RH
Storage: 5 to 85% RH
(with no icing or condensation)Characteristics
Contact resistance
Max. 50 mOhm, Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
Operating time (set time)
15 ms Max.
Release time (Reset time)
15 ms Max.
Min.set-reset signal width
30 ms Min.
Max.operating frequency (Mechanical)
18000 opn./h
Max.operating frequency (Erectrical)
1800 opn./h
Insulation resistance
Between coil and contacts: 100 MOhm Min. (at 500 VDC)
Between contacts of different polarity: 100 MOhm Min. (at 500 VDC)
Between contacts of same polarity: 100 MOhm Min. (at 500 VDC)
Between set and reset coils: 100 MOhm Min. (at 500 VDC)Dielectric strength
Between coil and contacts: 1500 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min)
Between contacts of different polarity: 1500 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min)
Between contacts of same polarity: 1000 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min)
Between set and reset coils: 1000 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min)Vibration resistance (Destruction)
10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) for 2 hours each in X, Y, and Z directions (No defect in appearance and construction after applying variable vibration in each directions for 2 hours.)
Vibration resistance (Malfunction)
10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) in each direction
Shock resistance (Destruction)
1000 m/s**2 each direction 3 times (No defect in appearance and construction after applying shock in each directions 3 times.)
Shock resistance (Malfunction)
200 m/s**2 (Contacts must not open for 1 ms or longer after the relay is subjected to a shock in each direction 3 times.)
Endurance (Mechanical)
100000000 operations Min.
Endurance (Electrical)
200000 operations Min.
Protective structure
Closed type (cover)
Applicable standard (UL)
Standard No.: UL508
File No.: E41515Applicable standard (CSA)
Standard No.: C22.2 No.0, No.14
File No.: LR31928Terminal structure
PCB
Weight
Approx. 30 g
No comment |