No comment |
LY3N OMRON RELAY NewProduct Description?
Ratings
Product classification
Monostable relays
Built-in LED indicator typeCoil ratings
48 VDC 28.2 mA
Coil resistance
1700 Ohm
Operate voltage (Set voltage)
80% Max.
Release voltage (Reset voltage)
10% Min.
Max. voltage
110% (of rated voltage)
Power consumption (Single stable)
1.4 W
Operating indicator
LED indicator
Coil surge killer
Not equipped
Contact Type
3PDT
Contact method
Single
Contact material
Contact body material: Ag alloy
Contact finish: NothingContact rated load
110 VAC 10 A (Resistive load (cos phi = 1))
110 VAC 7.5 A (Inductive load (cos phi = 0.4))
24 VDC 10 A (Resistive load)
24 VDC 5 A (Inductive load (L/R = 7 ms))Maximum switching voltage
250 VAC (Resistive load (cos phi = 1))
250 VAC (Inductive load (cos phi = 0.4))
125 VDC (Resistive load)
125 VDC (Inductive load (L/R = 7 ms))Maximum switching current
AC: 10 A (Resistive load (cos phi = 1))
AC: 10 A (Inductive load (cos phi = 0.4))
DC: 10 A (Resistive load)
DC: 10 A (Inductive load (L/R = 7 ms))Maximum switching power
AC: 1100 VA (Resistive load (cos phi = 1))
AC: 825 VA (Inductive load (cos phi = 0.4))
DC: 240 W (Resistive load)
DC: 120 W (Inductive load (L/R = 7 ms))Failure rate
100 mA at 5 VDC (failure level: P Reference value)
Ambient temperature
Operating: -25 to 40 CEL
Storage: -25 to 40 CEL
(with no icing or condensation)Ambient humidity
Operating: 5 to 85% RH
Storage: 5 to 85% RH
(with no icing or condensation)Characteristics
Contact resistance
Max. 50 mOhm, Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
Operating time (set time)
25 ms Max.
Release time (Reset time)
25 ms Max.
Max.operating frequency (Mechanical)
18000 opn./h
Max.operating frequency (Erectrical)
1800 opn./h
Insulation resistance
Between coil and contacts: 100 MOhm Min. (at 500 VDC)
Between contacts of different polarity: 100 MOhm Min. (at 500 VDC)
Between contacts of same polarity: 100 MOhm Min. (at 500 VDC)Dielectric strength
Between coil and contacts: 2000 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min)
Between contacts of different polarity: 2000 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min)
Between contacts of same polarity: 1000 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min)Vibration resistance (Destruction)
10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) for 2 hours each in X, Y, and Z directions (No defect in appearance and construction after applying variable vibration in each directions for 2 hours.)
Vibration resistance (Malfunction)
10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) in each direction
Shock resistance (Destruction)
1000 m/s**2 each direction 3 times (No defect in appearance and construction after applying shock in each directions 3 times.)
Shock resistance (Malfunction)
200 m/s**2 (Contacts must not open for 1 ms or longer after the relay is subjected to a shock in each direction 3 times.)
Endurance (Mechanical)
100000000 operations Min.
Endurance (Electrical)
200000 operations Min.
Protective structure
Closed type (cover)
Applicable standard (UL)
Standard No.: UL508
File No.: E41643Applicable standard (CSA)
Standard No.: C22.2 No.0, No.14
File No.: LR31928Applicable standard (TUV)
R50030064
Applicable standard (SEV)
98.5 50071.02
Applicable standard(Other)
Conformed standard 2: Electrical Appliance and Material Safety Law
Terminal structure
Plug-in
Weight
Approx. 50 g