No comment |
LY2N-J OMRON RELAY NewProduct Description?
Ratings
Product classification
Monostable relays
Built-in LED indicator typeCoil ratings
24 VAC 53.8 mA (50 Hz), 24 VAC 46 mA (60 Hz)
Coil resistance
180 Ohm
Operate voltage (Set voltage)
80% Max.
Release voltage (Reset voltage)
30% Min. (50 Hz), 30% Min. (60 Hz)
Max. voltage
110% (of rated voltage)
Power consumption (Single stable)
Approx. 1.0 to 1.2 VA (60 Hz)
Operating indicator
LED indicator
Coil surge killer
Not equipped
Contact Type
DPDT
Contact method
Single
Contact material
Contact body material: Ag alloy
Contact finish: NothingContact rated load
110 VAC 10 A (Resistive load (cos phi = 1))
110 VAC 7.5 A (Inductive load (cos phi = 0.4))
24 VDC 10 A (Resistive load)
24 VDC 5 A (Inductive load (L/R = 7 ms))Maximum switching voltage
250 VAC (Resistive load (cos phi = 1))
250 VAC (Inductive load (cos phi = 0.4))
125 VDC (Resistive load)
125 VDC (Inductive load (L/R = 7 ms))Maximum switching current
AC: 10 A (Resistive load (cos phi = 1))
AC: 10 A (Inductive load (cos phi = 0.4))
DC: 10 A (Resistive load)
DC: 10 A (Inductive load (L/R = 7 ms))Maximum switching power
AC: 1100 VA (Resistive load (cos phi = 1))
AC: 825 VA (Inductive load (cos phi = 0.4))
DC: 240 W (Resistive load)
DC: 120 W (Inductive load (L/R = 7 ms))Failure rate
100 mA at 5 VDC (failure level: P Reference value)
Ambient temperature
Operating: -25 to 40 CEL
Storage: -25 to 40 CEL
(with no icing or condensation)Ambient humidity
Operating: 5 to 85% RH
Storage: 5 to 85% RH
(with no icing or condensation)Characteristics
Contact resistance
Max. 50 mOhm, Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A
Operating time (set time)
25 ms Max.
Release time (Reset time)
25 ms Max.
Max.operating frequency (Mechanical)
18000 opn./h
Max.operating frequency (Erectrical)
1800 opn./h
Insulation resistance
Between coil and contacts: 100 MOhm Min. (at 500 VDC)
Between contacts of different polarity: 100 MOhm Min. (at 500 VDC)
Between contacts of same polarity: 100 MOhm Min. (at 500 VDC)Dielectric strength
Between coil and contacts: 2000 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min)
Between contacts of different polarity: 2000 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min)
Between contacts of same polarity: 1000 VAC 50/60 Hz for 1 min (Leakage current 3 mA 50/60 Hz 1 min)Vibration resistance (Destruction)
10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) for 2 hours each in X, Y, and Z directions (No defect in appearance and construction after applying variable vibration in each directions for 2 hours.)
Vibration resistance (Malfunction)
10 to 55 to 10 Hz 0.5-mm single amplitude (1.0-mm double amplitude) in each direction
Shock resistance (Destruction)
1000 m/s**2 each direction 3 times (No defect in appearance and construction after applying shock in each directions 3 times.)
Shock resistance (Malfunction)
200 m/s**2 (Contacts must not open for 1 ms or longer after the relay is subjected to a shock in each direction 3 times.)
Endurance (Mechanical)
50000000 operations Min.
Endurance (Electrical)
500000 operations Min.
Protective structure
Closed type (cover)
Applicable standard (UL)
Standard No.: UL508
File No.: E41643Applicable standard (CSA)
Standard No.: C22.2 No.0, No.14
File No.: LR31928Applicable standard (TUV)
R50030064
Applicable standard (SEV)
98.5 50071.02
Applicable standard (LR)
00/10047
Applicable standard(Other)
Conformed standard 2: Electrical Appliance and Material Safety Law
Terminal structure
Plug-in
Weight
Approx. 40 g
No comment |