No comment |
G3TA-OA202SL OMRON RELAY New
Product Description?
Input and output modules are available in wide variety.
Snaps easily into P7TF I/O Terminals and can be used together with G7T I/O relays.
Operation of each SSR can be monitored easily through an LED indicator.
Models certified for UL and CSA added to the series ("-US" models).
Specifications:
Model
Rated
voltageOperating voltage
Input
impedanceVoltage level
Must operate voltage
Must release
voltageG3TA-OA202SZ-US
12 VDC
9.6 to 13.2 VDC
0.9 kΩ±20%
9.6 VDC max.
2 VDC min.
24 VDC
19.2 to 26.4 VDC
1.7 kΩ±20%
19.2 VDC max.
G3TA-OA202SL-US
12 VDC
9.6 to 13.2 VDC
0.9 kΩ±20%
9.6 VDC max.
24 VDC
19.2 to 26.4 VDC
1.7 kΩ±20%
19.2 VDC max.
G3TA-ODX02S-US
12 VDC
9.6 to 13.2 VDC
3.5 kΩ±20%
9.6 VDC max.
24 VDC
19.2 to 26.4 VDC
6.5 kΩ±20%
19.2 VDC max.
G3TA-OD201S-US
12 VDC
9.6 to 13.2 VDC
3.6 kΩ±20%
9.6 VDC max.
24 VDC
19.2 to 26.4 VDC
6.4 kΩ±20%
19.2 VDC max.
Model
Rated load
voltageLoad voltage
rangeLoad current
(See note.)Inrush current
VDRM, VCEO
(reference value)G3TA-OA202SZ-US
100 to 240 VAC
75 to 264 VAC
0.05 to 2 A
30 A (60 Hz, 1 cycle)
600 (VDRM)
G3TA-OA202SL-US
100 to 240 VAC
75 to 264 VAC
G3TA-ODX02S-US
5 to 48 VDC
4 to 60 VDC
0.01 to 2 A
12 A (10 ms)
80 (VCEO)
G3TA-OD201S-US
48 to 200 VDC
40 to 200 VDC
0.01 to 1 A
6 A (10 ms)
400 (VCEO)
Note:The minimum current value is measured at 10°C min.
Certified standards
G3TA-OA202SZ-US
G3TA-OA202SL-US
G3TA-ODX02S-US
G3TA-OD201S-US
Operate time
1/2 of load power source
cycle + 1 ms max.1 ms max.
0.5 ms max.
2 ms max.
Release time
1/2 of load power source
cycle + 1 ms max.2 ms max.
2 ms max.
Output ON
voltage drop1.6 V rms max.
1.6 V max.
2.5 V max.
Leakage
current5 mA max. (at 200 VAC)
1 mA max.
Insulation
resistance100 MΩ min. (at 500 VDC)
Dielectric
strength4,000 VAC, 50/60 Hz for 1 min between input and output
Vibration
resistanceMalfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
Shock
resistanceMalfunction: 1,000 m/s2
Ambient
temperatureOperating: -30°C to 80°C (with no icing or condensation)
Storage: -30°C to 100°C (with no icing or condensation)Ambient humidity
Operating: 45% to 85%
Certified standards
UL508 file No. E64562, CSA C22.2 (No. 14) file No. LR3553
Weight
Approx. 23 g
With up to four G3TA SSRs mounted before G7T Relays, switching is possible at the rated load current for each Relay.
With G3TA SSRs mounted before every other G7T Relays, switching is possible at the rated load current for each Relay.
Caution: In the interest of product improvement, specifications are subject to change without notice.
No comment |