No comment |
Product Description?
Input and output modules are available in wide variety.
Snaps easily into P7TF I/O Terminals and can be used together with G7T I/O relays.
Operation of each SSR can be monitored easily through an LED indicator.
Models certified for UL and CSA added to the series ("-US" models).
Specifications:
Model | Rated voltage | Operating voltage | Input | Voltage level | |
Must operate | Must release | ||||
G3TA-IAZR02S-US | 100 to 240 VAC | 80 to 264 VAC | 5 mA max. | 80 VAC max. | 10 VAC min. |
G3TA-IDZR02S-US | 5 to 24 VDC | 4 to 32 VDC | 4 VDC max. | 1 VDC min. | |
G3TA-IDZR02SM-US | 4 to 24 VDC | 3 to 32 VDC | 3 VDC max. |
Output
Model | Logic level supply | Output breakdown | Output current | Output current | VCEO | |||
G3TA-IAZR02S-US | 4 to 32 VDC | 32 VDC max. | 25 mA max. | 0.1 to 25 mA | 80 V | |||
G3TA-IDZR02S-US | ||||||||
G3TA-IDZR02SM-US | ||||||||
Item | G3TA-IAZR02S-US | G3TA-IDZR02S-US | G3TA-IDZR02SM-US | |||||
Operate time | 20 ms max. | 0.5 ms max. | ||||||
Release time | 20 ms max. | 0.5 ms max. | ||||||
Output ON voltage drop | 1.6 V max. | 1.6 V max. | ||||||
Leakage current | 5 μA max. | |||||||
Insulation resistance | 100 MΩ min. (at 500 VDC) | |||||||
Dielectric strength | 4,000 VAC, 50/60 Hz for 1 min between input and output | |||||||
Vibration resistance | Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude | |||||||
Shock resistance | Malfunction: 1,000 m/s2 | |||||||
Ambient temperature | Operating: -30°C to 80°C (with no icing or condensation) | |||||||
Ambient humidity | Operating: 45% to 85% | |||||||
Certified standards | UL508 file No. E64562/CSA C22.2 (No. 0, No. 14) file No. LR35535 | |||||||
Weight | Approx. 16 g | |||||||
With up to four G3TA SSRs mounted before G7T Relays, switching is possible at the rated load current for each Relay.
With G3TA SSRs mounted before every other G7T Relays, switching is possible at the rated load current for each Relay.
Caution: In the interest of product improvement, specifications are subject to change without notice.
G3TA-IDZR02S OMRON RELAY NewProduct Description?
Input and output modules are available in wide variety.
Snaps easily into P7TF I/O Terminals and can be used together with G7T I/O relays.
Operation of each SSR can be monitored easily through an LED indicator.
Models certified for UL and CSA added to the series ("-US" models).
Specifications:
Model
Rated voltage
Operating voltage
Input
currentVoltage level
Must operate
voltageMust release
voltageG3TA-IAZR02S-US
100 to 240 VAC
80 to 264 VAC
5 mA max.
80 VAC max.
10 VAC min.
G3TA-IDZR02S-US
5 to 24 VDC
4 to 32 VDC
4 VDC max.
1 VDC min.
G3TA-IDZR02SM-US
4 to 24 VDC
3 to 32 VDC
3 VDC max.
Output
Model
Logic level supply
voltageOutput breakdown
voltageOutput current
Output current
(load current)VCEO
(reference value)G3TA-IAZR02S-US
4 to 32 VDC
32 VDC max.
25 mA max.
0.1 to 25 mA
80 V
G3TA-IDZR02S-US
G3TA-IDZR02SM-US
Item
G3TA-IAZR02S-US
G3TA-IDZR02S-US
G3TA-IDZR02SM-US
Operate time
20 ms max.
0.5 ms max.
Release time
20 ms max.
0.5 ms max.
Output ON voltage drop
1.6 V max.
1.6 V max.
Leakage current
5 μA max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between input and output
Vibration resistance
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude
Shock resistance
Malfunction: 1,000 m/s2
Ambient temperature
Operating: -30°C to 80°C (with no icing or condensation)
Storage: -30°C to 100°C (with no icing or condensation)Ambient humidity
Operating: 45% to 85%
Certified standards
UL508 file No. E64562/CSA C22.2 (No. 0, No. 14) file No. LR35535
Weight
Approx. 16 g
With up to four G3TA SSRs mounted before G7T Relays, switching is possible at the rated load current for each Relay.
With G3TA SSRs mounted before every other G7T Relays, switching is possible at the rated load current for each Relay.
Caution: In the interest of product improvement, specifications are subject to change without notice.
No comment |