We use cookies 🍪
We use cookies and other similar technologies to improve your browsing experience and the functionality of our site. Learn more in our Privacy Policy.

Multimeter 4 1/2 Logging of True-rms digital VC189 VICTOR

Multimeter 4 1/2 Logging of True-rms digital  VC189 VICTOR
Multimeter 4 1/2 Logging of True-rms digital  VC189 VICTOR
Multimeter 4 1/2 Logging of True-rms digital  VC189 VICTOR
Multimeter 4 1/2 Logging of True-rms digital  VC189 VICTOR
Multimeter 4 1/2 Logging of True-rms digital VC189 VICTOR
PLCAGE:Multimeter 4 1/2 Logging of True-rms digital  VC189 VICTORCharacteristicsl MeasurementsAC vol... Read More
$380.00
Ex Tax: $380.00
  • Stock: In Stock
  • Model: VC189 VICTOR
  • Weight: 0.50kg
1. We typically ship items within three business days after payment is received.
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.

Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
We accept many payments,include Paypal,Bank Transfer etc
Tags: VC189 VICTOR

PLCAGE:Multimeter 4 1/2 Logging of True-rms digital  VC189 VICTOR

Characteristics

l Measurements

AC voltage, DC voltage, AC current ,DC current, OHM, Frequency, Period, Pulse width,Capacitance, Beep, Diode, dBm, Thermocouple (TC), Thermal resistance (RTD), AC+ DC, AC + Hz measurement, Maximum, Minimum, Average measurement (MAX / MIN / AVG), The relative value measurement (REL_%)

l Measurements show that 55,000 words, the basic accuracy 0.02% (VICTOR 189) / 0.05% (VICTOR 187)

l Three measurement rate: FAST, SLOW, SMOOTH, the fastest refresh rate of simulation bar: 14 / sec

l Manual range or automatic range selection

l Measuring data show that hold functional (DIS_HOLD) and automatically hold functions(AUTO_HOLD)

l Peak measurements, 500us peak sampling capture, capable of capturing crest Pulse

l AC voltage and AC current are true rms measurement, AC voltage bandwidth 20Hz~30KHz(VICTOR 187),20Hz-100KHz(VICTOR 189), AC current bandwidth 20Hz-30KHz

l Option 1 ~ 2400 Ω reference impedance measurement of decibels

l Low pass filter function normally by the RP-raising and the frequency of the electrical waveform measurement results

l Can be configured clamp to measure the large current

l The eight kinds of thermocouple measurement, the two kinds of heat resistance measurement, high-precision cold-automatic compensation, ? or ? temperature display

l Large-screen display and more data can be displayed at the same time that is measurements and other information related to the measurement

l Built-in real-time clock, for the record and provide accurate measurement of time

l Easy to operate multi-parameter data record: manual records and records of the incident, and easy to query the data records

l Adopted panel calibration technology, can be done without opening the case calibration

l Use alkaline batteries, Ni-Hi battery-powered, the battery and fuse can be easily replaced.

l Backlight is automatically closed and automatic power off function

l Large-screen LCD display, with white LED backlighting

l The meter can communicate with computer by isolation interface USB

l Through the friendly interface, users can easily access the data of instrument in a number of parameters, and may be the data storage, processing, management, access to the data tables and other graphics or display

l Simple man-machine operating, delicate, strongly and suitable for field use

Specifications for products

Measurements

Range

Measuring range

Resolution

DCV

5.0000V

0.0001V

Input impedance:

10MΩ

50.000V

0.001V

500.00V

0.01V

1000.0V

0.1V

DCmV

50.000mV

0.001mV

Input impedance:

approx. 100MΩ

500.00mV

0.01mV

2200.0mV

0.1mV

ACV 

5.0000V

0.0001V

Input impedance:

10MΩ / 50pF

CF<3

187:

20Hz~30kHz

(10~110% Range)

189:

20Hz~100kHz

(5~110% Range)

50.000V

0.001V

500.00V

0.01V

760.0V

0.1V

ACmV

50.000mV

0.001mV

Input impedance:

1MΩ / 50pF

500.00mV

0.01mV

OHM

500.00Ω

0.01Ω

Open circuit voltage

<2.5V

5.0000KΩ

0.0001KΩ

50.000KΩ

0.001KΩ

500.00KΩ

0.01KΩ

5.0000MΩ

0.0001 MΩ

50.000MΩ

0.001 MΩ

500.0MΩ

0.1 MΩ

DCA

5.0000A

0.0001 A

Voltage Drop <0.04 V/A

20.000A

0.001 A

DCmA

50.000mA

0.001mA

Voltage Drop

<1.8 mV/mA

500.00mA

0.01 mA

DCuA

500.00uA

0.01 uA

Voltage Drop

103uV/uA

5000.0uA

0.1 uA

5.0000A

0.0001 A

ACmA

50.000mA

0.001mA

500.00mA

0.01 mA

ACuA

500.00uA

0.01uA

50000uA

0.1uA

FREQ

9.9999Hz

0.0001Hz

 

99.999Hz

0.001Hz

999.99Hz

0.01Hz

9.9999KHz

0.0001KHz

99.999KHz

0.001KHz

999.99KHz

 

0.01KHz

  

9.9999MHz

0.0001MHz

99.999MHz

0.001MHz

   

DUTY

0.1%~99.9%

0.1%

0.5Hz~1KHz,

Square Wave

 

PULSE

199.99ms

0.01ms

1999.9ms

0.1ms

DIODE

2.2000V

0.0001V

Open circuit voltage:<3.5V

Short circuit:0.8mA

CHCNT

500.0Ω

0.1Ω

Open circuit voltage:<3.5V

Short circuit:<0.8mA

Short alarm:approx. <20Ω

Open alarm:approx. >120Ω

CAP

9.999nF

0.001nF

 

99.99nF

0.01nF

999.9nF

0.1nF

9.999μF

0.001uF

99.99μF

0.01uF

999.9μF

0.1uF

9.999mF

0.001mF

99.99mF

0.01mF

TC

R

-40°C~1760°C

1°C

ITS-90

S

-40°C~1760°C

K

-270.0~1370.0

0.1°C

E

-270.0~720.0

0.1°C

J

-210.0~850.0

0.1°C

T

-270.0~400.0

0.1°C

N

-270.0~1300.0

0.1°C

B

400~1800

1°C

RTD

Pt100

-200.0~850.0

0.1°C

Pt100-385

Pt1000

-200.0~630.0

0.1°C

 

Other Features:

l DC Voltage measurement

CMRR:50Hz / 60Hz ≥ 120dB

SMRR:50Hz / 60Hz(Rs=1kΩ) ≥ 80dB

l AC Voltage measurement

CMRR:50Hz / 60Hz(Rs=1kΩ) ≥ 80 dB

A residual reading with input shorted, will not affect stated accuracy above 5 % of range.

l OHM measurement

For relative humidity greater than 70 %, resistance accuracy is 0.5 % over 1 MΩand 2.5 % over 10 MΩ.

l Internal temperature compensation sensor RJC:

temperature range: -10 ~ 50?, compensation error ≤ ± 0.5 ?, compensation time for 10 seconds each time

l Maximum voltage between any Terminal and Earth Ground :

1000V DC / AC rms
Fuse protection for mA input: 500 mA / 250V FAST fuse
fuse protection for 20A input: 20 A / 250V FAST fuse
Can be as high as 20 A continuous measurement of the current, if the signal detected in 10 A ~ 20 A of maintaining maximum of 30 seconds, then specified the need to increase the accuracy of 0.5%

l Real-Time Clock
≤ ± 1min / 1month
Temp. Influence 50 ppm per C

l Measured rate

Functional range

Measuring rate

FAST

SLOW

SMOOTH

DC voltage and current

14

7

1

AC voltage and current

14

/

1.8

Resistors, diodes, on-off

7

/

1.8

 

General Specifications:

l Operating Temperature and Humidity

0 to 50oC,(no condensation ≤10oC) ≤ 85%RH

l Storage Temperature and Relative Humidity

-20oC to 60oC,≤90%RH

l Altitude

2000m max. above sea level

l Rated transient over-voltage

6KV(1.2*50us)CAT?, CAI ?, CAT ? peak measurement

l Vibration and Shock

Random 2g, 5 to 500Hz

1 meter drop test

l Period of calibration and warm-up time

Accuracy is specified for a period of one year after calibration or other

Warm-up time is 10 minutes or other

l Display and LED

* LCD:36.3×68.0mm

* white LED,able to set time 0~9999S

l Supply

* 4 x 1.5V Alkaline batteries supply

               * 4 x 1.2V Ni-Hi batteries supply

               * Auto Power-off:able to set time 0~9999minutes

l Safety Standards

IEC 61010-1, 2000

Overvoltage category III (Max. input voltage:AC/DC600V)

Overvoltage category II (Max. input voltage:AC/DC1000V)

Pollution degree 2

l Weight and Size

205 × 95 × 42(mm) ,approximate 500g

 