Double Clamp Digital Phase Meter VICTOR 4000 VICTORPLCAGE: Double Clamp Digital Phase Meter VICTOR 4000 VICTOR1.Base Conditions and Working Conditions
Influence Quantity
Base Condition
Working Conditions
Remark
Ambient Temp
23±1
-10~40
Ambient Humidity
40%~60%
<80%
Signal Waveform
sine wave
sine wave
β=0.05
Signal Frequency
50HZ±1HZ
45HZ~65HZ
Meter Working Volt
9V±0.1V
9V±1V
External Electric, Magnetic Field
To be avoided
Measured Wire Position
Measured wire at approximately the geometric center of the clamp
2.General Specification
Function
Phase, AC current, AC voltage, AC leakage current, direct test of phase sequence; transformer groups, inductive, capacitive circuit discrimination; indirect test of power factor and power
Power
DC9V alkaline batteries(1.5V AA×6)
Consumption
About 35mA at most with enabled backlight, battery working continuously for about 40 hours
-3-
About 5mA with disabled backlight, battery working continuously for about 300 hours
Display Mode
LCD display, blue backlight, suitable for dark places
LCD Size
70mm×62mm
LCD Display Field
64mm×54mm
Meter Size
Length, Width, Height:196mm×92mm×54mm
Clamp Size
φ7.5mm×13mm
Sampling Rate
About 3 times/second
Measurement Range
AC Voltage:0~20V/200V/500V
AC Current:0~200mA/2A/10A
Phase:0~360
Measured Signal Amplitude in Phase Test
U1-U2 phase test:30V~500V
I1-I2 phase test:10mA~10.00A
U1-I2 or I1-U2 phase test:10V~500V,10mA~10.00A
Data Hold
Press HOLD key to keep data, "DH" symbol appears
Automatic Shutdown
Automatic shutdown about 15 minutes later after launching to reduce battery consumption, ,
Voltage Detection
Low battery symbol " " appears to remind the replacement of battery when the battery voltage drops below 7.8V~8V.
Weight
Main Unit about 550g(with battery),clamp about 170g×2,test line about 250g
Test Line Length
1.5m
Current Clamp Length
2m
Working Temperature and Humidity
-10°c~40°c; below 80%Rh
Storage Temperature and Humidity
-10°c~60°c; below 70%Rh
Input Impedance
Input impedance for all test voltage range:2MΩ
Input impedance when testing U1U2 phase:40KΩ
Withstand Voltage
Withstand 1000V/50Hz sine wave AC voltage for 1 minute between the meter lines and shell; Withstand 500V/50Hz AC voltage sine wave for 1 minute between the two voltage inputs
Insulation
≥10MΩ between meter lines and shell or between the two voltage inputs
Structure
-4-
Double insulation
3.Intrinsic error and performance indicators under base conditions
Category
Measurement Range
Resolution
Intrinsic Error
Voltage
20V
0.01V
±(1.2%rdg+2dgt)
200V
0.1V
500V
1V
Current
200mA
0.1mA
±(1.0%rdg+2dgt)
2A
1mA
10A
10mA
Phase
0~360
1
±3